Combined in vivo and ex vivo analysis of mesh mechanics in a porcine hernia model

被引:6
|
作者
Kahan, Lindsey G. [1 ]
Lake, Spencer P. [2 ,3 ,4 ]
McAllister, Jared M. [1 ]
Tan, Wen Hui [1 ]
Yu, Jennifer [1 ]
Thompson, Dominic, Jr. [1 ]
Brunt, L. Michael [1 ]
Blatnik, Jeffrey A. [1 ]
机构
[1] Washington Univ, Dept Surg, Sch Med, 660 South Euclid Ave,Campus Box 8109, St Louis, MO 63110 USA
[2] Washington Univ, Dept Mech Engn & Mat Sci, St Louis, MO USA
[3] Washington Univ, Dept Orthopaed Surg, St Louis, MO USA
[4] Washington Univ, Dept Biomed Engn, St Louis, MO USA
关键词
Ventral hernia; Mesh; Porcine model; Mechanics; HUMAN ABDOMINAL-WALL; VENTRAL HERNIA; INCISIONAL HERNIA; RECTUS SHEATH; LINEA ALBA; LAPAROSCOPIC SURGERY; SYNTHETIC SCAFFOLDS; SURGICAL MESH; REPAIR; POLYPROPYLENE;
D O I
10.1007/s00464-017-5749-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Hernia meshes exhibit variability in mechanical properties, and their mechanical match to tissue has not been comprehensively studied. We used an innovative imaging model of in vivo strain tracking and ex vivo mechanical analysis to assess effects of mesh properties on repaired abdominal walls in a porcine model. We hypothesized that meshes with dissimilar mechanical properties compared to native tissue would alter abdominal wall mechanics more than better-matched meshes. Methods Seven mini-pigs underwent ventral hernia creation and subsequent open repair with one of two heavyweight polypropylene meshes. Following mesh implantation with attached radio-opaque beads, fluoroscopic images were taken at insufflation pressures from 5 to 30 mmHg on postoperative days 0, 7, and 28. At 28 days, animals were euthanized and ex vivo mechanical testing performed on full-thickness samples across repaired abdominal walls. Testing was conducted on 13 mini-pig controls, and on meshes separately. Stiffness and anisotropy (the ratio of stiffness in the transverse versus craniocaudal directions) were assessed. Results 3D reconstructions of repaired abdominal walls showed stretch patterns. As pressure increased, both meshes expanded, with no differences between groups. Over time, meshes contracted 17.65% (Mesh A) and 0.12% (Mesh B; p = 0.06). Mesh mechanics showed that Mesh A deviated from anisotropic native tissue more than Mesh B. Compared to native tissue, Mesh A was stiffer both transversely and craniocaudally. Explanted repaired abdominal walls of both treatment groups were stiffer than native tissue. Repaired tissue became less anisotropic over time, as mesh properties prevailed over native abdominal wall properties. Conclusions This technique assessed 3D stretch at the mesh level in vivo in a porcine model. While the abdominal wall expanded, mesh-ingrown areas contracted, potentially indicating stresses at mesh edges. Ex vivo mechanics demonstrate that repaired tissue adopts mesh properties, suggesting that a better-matched mesh could reduce changes to abdominal wall mechanics.
引用
收藏
页码:820 / 830
页数:11
相关论文
共 50 条
  • [21] Porcine Hemagglutinating Encephalomyelitis Virus Infection In Vivo and Ex Vivo
    Mora-Diaz, Juan Carlos
    Pineyro, Pablo E.
    Rauh, Rolf
    Nelson, William
    Sankoh, Zianab
    Gregg, Edward
    Antonio Carrillo-Avila, Jose
    Shen, Huigang
    Nelli, Rahul K.
    Zimmerman, Jeffrey J.
    Gimenez-Lirola, Luis G.
    JOURNAL OF VIROLOGY, 2021, 95 (12)
  • [22] Ex vivo resuscitation of porcine hearts
    Herrera, P.
    Rosenstrauch, D.
    Akay, H.
    Inman, R.
    Beyer, E.
    Frazier, O.H.
    Radovaneevie, B.
    Kadipasaoglu, K.
    ASAIO Journal, 2000, 46 (02)
  • [23] Mechanical response of human abdominal walls ex vivo: Effect of an incisional hernia and a mesh repair
    Podwojewski, F.
    Ottenio, M.
    Beillas, P.
    Guerin, G.
    Turquier, F.
    Mitton, D.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 38 : 126 - 133
  • [24] Safety testing of indocyanine green in an ex vivo porcine retina model
    Saikia, Parykshit
    Maisch, Tim
    Kobuch, Karin
    Jackson, Timothy L.
    Baeumler, Wolfgang
    Szeimies, Rolf-Markus
    Gabel, Veit-Peter
    Hillenkamp, Jost
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (11) : 4998 - 5003
  • [25] Corneal epithelial cell viability of an ex vivo porcine eye model
    Chan, Ka Yin
    Cho, Pauline
    Boost, Maureen
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2014, 97 (04) : 337 - 340
  • [26] Morphometric Characterization of an Ex Vivo Porcine Model of Functional Tricuspid Regurgitation
    Eleonora Salurso
    Michal Jaworek
    Francesca Perico
    Matteo Frigelli
    Claudia Romagnoni
    Monica Contino
    Guido Gelpi
    Gianfranco Beniamino Fiore
    Riccardo Vismara
    Annals of Biomedical Engineering, 2023, 51 : 715 - 725
  • [27] An ex vivo porcine model of the anterior glottoplasty for voice feminization surgery
    Rohlfing, Matthew L.
    Kuperstock, Jacob E.
    Friedman, Daniel
    Spiegel, Jeffrey H.
    LARYNGOSCOPE, 2020, 130 (04): : E206 - E212
  • [29] VALIDATION AND APPLICATION OF AN EX VIVO PORCINE MODEL FOR PREDICTING THE PERMEABILITY OF THE UROTHELIUM
    Joshi, Hrishi B.
    Allender, Chris J.
    Bowen, Jenna L.
    Awadalla, Widatella
    JOURNAL OF ENDOUROLOGY, 2011, 25 : A1 - A1
  • [30] Development of an Ex Vivo Porcine Training Model for Laparoscopic Right Hemicolectomy
    Celentano, V.
    George, R.
    Credland, T.
    Robinson, J.
    Griffith, J.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 213 - 213