Supersensitive time-resolved immunofluorometric assay of free prostate-specific antigen with nanoparticle label technology

被引:1
|
作者
Soukka, T [1 ]
Paukkunen, J [1 ]
Härmä, H [1 ]
Lönnberg, S [1 ]
Lindroos, H [1 ]
Lövgren, T [1 ]
机构
[1] Univ Turku, Dept Biotechnol, FIN-20520 Turku, Finland
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The extreme specific activity of the long-lifetime fluorescent europium(III) chelate nanoparticles and the enhanced monovalent binding affinity of multivalent nanoparticle-antibody bioconjugates are attractive for noncompetitive immunoassay. Methods: We used a noncompetitive, two-step immunoassay design to measure free prostate-specific antigen (PSA). Europium(III) chelate nanoparticles (107 nm in diameter) were coated with a monoclonal anti-PSA antibody (intrinsic affinity, 6 x 10(9) L/mol). The nanoparticle-antibody bioconjugates had an average of 214 active binding sites per particle and a monovalent binding affinity of 7 x 10(10) L/mol. The assay was performed in a low-fluorescence microtitration well passively coated with an another monoclonal anti-PSA antibody (affinity, 2 x 10(10) L/mol), and the europium(III) fluorescence was measured directly from the bottom of the well by a standard time-resolved microtitration plate fluorometer. Results: The detection limit (mean + 2 SD) was 0.040 ng/L (7.3 x 10(5) molecules/ml), and the dynamic detection range covered four orders of magnitude in a 3-h total assay time. The imprecision (CV) over the whole assay range was 2-10%. The detection limit of the assay was limited by the fractional nonspecific binding of the bioconjugate to the solid phase (0.05%), which was higher than the nonspecific binding of the original antibody (<0.01%). Conclusions: The sensitivity of the new assay is equal to that of the ambient-analyte, microspot immunoassay and will be improved by use of optimized, high binding-site density nanoparticle-antibody bioconjugates with reduced nonspecific binding and improved monovalent binding affinity. (C) 2001 American Association for Clinical Chemistry.
引用
收藏
页码:1269 / 1278
页数:10
相关论文
共 50 条
  • [41] SIMULTANEOUS QUANTIFICATION OF 2 PLANT-VIRUSES BY DOUBLE-LABEL TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY
    SAARMA, M
    JARVEKULG, L
    HEMMILA, I
    SIITARI, H
    SINIJARV, R
    JOURNAL OF VIROLOGICAL METHODS, 1989, 23 (01) : 47 - 54
  • [42] Sensitive miniature single-particle immunoassay of prostate-specific antigen using time-resolved fluorescence
    Härmä, H
    Pelkkikangas, AM
    Soukka, T
    Huhtinen, P
    Huopalahti, S
    Lövgren, T
    ANALYTICA CHIMICA ACTA, 2003, 482 (02) : 157 - 164
  • [43] POTENTIAL OF AVIDIN BIOTIN SYSTEM IN TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY (TRIFMA)
    BADOR, R
    DECHAUD, H
    CLAUSTRAT, F
    CLINICAL CHEMISTRY, 1988, 34 (03) : 596 - 597
  • [44] 2-SITE TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY OF HUMAN INSULIN
    TOIVONEN, E
    HEMMILA, I
    MARNIEMI, J
    JORGENSEN, PN
    ZEUTHEN, J
    LOVGREN, T
    CLINICAL CHEMISTRY, 1986, 32 (04) : 637 - 640
  • [45] TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY OF SEX-HORMONE BINDING GLOBULIN
    NIEMI, S
    MAENTAUSTA, O
    BOLTON, NJ
    HAMMOND, GL
    CLINICAL CHEMISTRY, 1988, 34 (01) : 63 - 66
  • [46] TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY FOR THYROXINE-BINDING GLOBULIN IN SERUM
    TAN, YK
    KHOSRAVI, MJ
    DIAMANDIS, EP
    JOURNAL OF IMMUNOASSAY, 1989, 10 (04): : 413 - 428
  • [47] A time-resolved immunofluorometric assay of autoantibodies to double-stranded DNA
    Veer, GVDS
    Moens, HJB
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1996, 34 (11): : 915 - 920
  • [48] DETERMINATION OF ANTI-CRYPTOSPORIDIUM COPROANTIBODIES BY TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY
    KAPEL, N
    MEILLET, D
    BURAUD, M
    FAVENNEC, L
    MAGNE, D
    GOBERT, JG
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1993, 87 (03) : 330 - 332
  • [49] A TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY FOR QUANTITATIVE MEASUREMENT OF PROINSULIN IN HUMAN SERUM
    ENGLING, U
    MISSLER, U
    KERNER, W
    DIABETES, 1993, 42 : A174 - A174
  • [50] Technical note: Time-resolved immunofluorometric assay for growth hormone in ruminants
    Lovendahl, P
    Adamsen, J
    Lund, R
    Lind, P
    JOURNAL OF ANIMAL SCIENCE, 2003, 81 (05) : 1294 - 1299