Supersensitive time-resolved immunofluorometric assay of free prostate-specific antigen with nanoparticle label technology

被引:1
|
作者
Soukka, T [1 ]
Paukkunen, J [1 ]
Härmä, H [1 ]
Lönnberg, S [1 ]
Lindroos, H [1 ]
Lövgren, T [1 ]
机构
[1] Univ Turku, Dept Biotechnol, FIN-20520 Turku, Finland
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The extreme specific activity of the long-lifetime fluorescent europium(III) chelate nanoparticles and the enhanced monovalent binding affinity of multivalent nanoparticle-antibody bioconjugates are attractive for noncompetitive immunoassay. Methods: We used a noncompetitive, two-step immunoassay design to measure free prostate-specific antigen (PSA). Europium(III) chelate nanoparticles (107 nm in diameter) were coated with a monoclonal anti-PSA antibody (intrinsic affinity, 6 x 10(9) L/mol). The nanoparticle-antibody bioconjugates had an average of 214 active binding sites per particle and a monovalent binding affinity of 7 x 10(10) L/mol. The assay was performed in a low-fluorescence microtitration well passively coated with an another monoclonal anti-PSA antibody (affinity, 2 x 10(10) L/mol), and the europium(III) fluorescence was measured directly from the bottom of the well by a standard time-resolved microtitration plate fluorometer. Results: The detection limit (mean + 2 SD) was 0.040 ng/L (7.3 x 10(5) molecules/ml), and the dynamic detection range covered four orders of magnitude in a 3-h total assay time. The imprecision (CV) over the whole assay range was 2-10%. The detection limit of the assay was limited by the fractional nonspecific binding of the bioconjugate to the solid phase (0.05%), which was higher than the nonspecific binding of the original antibody (<0.01%). Conclusions: The sensitivity of the new assay is equal to that of the ambient-analyte, microspot immunoassay and will be improved by use of optimized, high binding-site density nanoparticle-antibody bioconjugates with reduced nonspecific binding and improved monovalent binding affinity. (C) 2001 American Association for Clinical Chemistry.
引用
收藏
页码:1269 / 1278
页数:10
相关论文
共 50 条
  • [1] TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY OF HUMAN PROSTATE-SPECIFIC ANTIGEN
    VIHKO, P
    KURKELA, R
    RAMBERG, J
    PELKONEN, I
    VIHKO, R
    CLINICAL CHEMISTRY, 1990, 36 (01) : 92 - 95
  • [2] Dual-label time-resolved immunofluorometric assay of free and total prostate-specific antigen based on recombinant Fab fragments
    Eriksson, S
    Vehniäinen, M
    Jansén, T
    Meretoja, V
    Saviranta, P
    Pettersson, K
    Lövgren, T
    CLINICAL CHEMISTRY, 2000, 46 (05) : 658 - 666
  • [3] DOUBLE-LABEL TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY OF PROSTATE-SPECIFIC ANTIGEN AND OF ITS COMPLEX WITH ALPHA(1)-ANTICHYMOTRYPSIN
    LEINONEN, J
    LOVGREN, T
    VORNANEN, T
    STENMAN, UH
    CLINICAL CHEMISTRY, 1993, 39 (10) : 2098 - 2103
  • [4] Performance of a nanoparticle-based supersensitive time-resolved immunofluorometric assay of free PSA.
    Soukka, T
    Antonen, K
    Härmä, H
    Pelkkikangas, AM
    Huhtinen, P
    CLINICAL CHEMISTRY, 2002, 48 (06) : A24 - A25
  • [5] ULTRASENSITIVE TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY OF PROSTATE-SPECIFIC ANTIGEN IN SERUM AND PRELIMINARY CLINICAL-STUDIES
    YU, H
    DIAMANDIS, EP
    CLINICAL CHEMISTRY, 1993, 39 (10) : 2108 - 2114
  • [6] Ultrasensitive detection of prostate-specific antigen by a time-resolved immunofluorometric assay and the immulite(R) immunochemiluminescent third-generation assay: Potential applications in prostate and breast cancers
    Ferguson, RA
    Yu, H
    Kalyvas, M
    Zammit, S
    Diamandis, E
    CLINICAL CHEMISTRY, 1996, 42 (05) : 675 - 684
  • [7] DESIGN OF A TIME-RESOLVED FLUOROMETRIC HYBRIDIZATION ASSAY FOR THE MESSENGER-RNA OF PROSTATE-SPECIFIC ANTIGEN
    GALVAN, B
    CHRISTOPOULOS, TK
    DIAMANDIS, EP
    CLINICAL CHEMISTRY, 1995, 41 (11) : 42 - 42
  • [8] A DOUBLE MONOCLONAL TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY OF CARCINOEMBRYONIC ANTIGEN IN SERUM
    BHAYANA, V
    DIAMANDIS, EP
    CLINICAL BIOCHEMISTRY, 1989, 22 (06) : 433 - 438
  • [9] Immunoassay on a single microparticle:: the effect of particle size and number on a miniaturized time-resolved fluorometric assay of free prostate-specific antigen
    Härmä, H
    Lehtinen, P
    Takalo, H
    Lövgren, T
    ANALYTICA CHIMICA ACTA, 1999, 387 (01) : 11 - 19
  • [10] EUROPIUM AS A LABEL IN TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAYS
    HEMMILA, I
    DAKUBU, S
    MUKKALA, VM
    SIITARI, H
    LOVGREN, T
    ANALYTICAL BIOCHEMISTRY, 1984, 137 (02) : 335 - 343