Detection of Winding Asymmetries in Wound-Rotor Induction Motors via Transient Analysis of the External Magnetic Field

被引:53
|
作者
Zamudio-Ramirez, Israel [1 ]
Alfonso Antonino-Daviu, Jose [2 ]
Osornio-Rios, Roque A. [1 ]
de Jesus Romero-Troncoso, Rene [1 ]
Razik, Hubert [3 ]
机构
[1] Univ Autonoma Queretaro, Fac Ingn, CA Mecatron, Campus San Juan del Rio, San Juan Del Rio 76807, Mexico
[2] Univ Politecn Valencia, Inst Tecnol Energia, E-46022 Valencia, Spain
[3] Univ Lyon, Univ Claude Bernard, Lab Ampere, CNRS, F-69621 Villeurbanne, France
关键词
Rotors; Induction motors; Sensors; Windings; Transient analysis; Magnetic fields; Discrete wavelet transforms; Stray flux; time-frequency transforms; transient analysis; wound rotor induction motor (WRIM); DIAGNOSIS; MACHINES; FAULTS;
D O I
10.1109/TIE.2019.2931274
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Over recent decades, the detection of faults in induction motors (IMs) has been mainly focused in cage motors due to their extensive use. However, in recent years, wound-rotor motors have received special attention because of their broad use as generators in wind turbine units, as well as in some large power applications in industrial plants. Some classical approaches perform the detection of certain faults based on the fast Fourier transform analysis of the steady state current (motor current signature analysis); they have been lately complemented with new transient time-frequency-based techniques to avoid false alarms. Nonetheless, there is still a need to improve the already existing methods to overcome some of their remaining drawbacks and increase the reliability of the diagnostic. In this regard, emergent technologies are being explored, such as the analysis of stray flux at the vicinity of the motor, which has been proven to be a promising option to diagnose the motor condition. Recently, this technique has been applied to detect broken rotor bar failures and misalignments in cage motors, offering the advantage of being a noninvasive tool with simple implementation and even avoiding some drawbacks of well-established tools. However, the application of these techniques to wound rotor IMs (WRIMs) has not been studied. This article explores the analysis of the external magnetic field under the starting to detect rotor winding asymmetry defects in WRIMs by using advanced signal processing techniques. Moreover, a new fault indicator based on this quantity is introduced, comparing different levels of fault and demonstrating the potential of this technique to quantify and monitor rotor winding asymmetries in WRIMs.
引用
收藏
页码:5050 / 5059
页数:10
相关论文
共 50 条
  • [1] Robust Detection of Rotor Winding Asymmetries in Wound Rotor Induction Motors via Integral Current Analysis
    Antonino-Daviu, Jose
    Quijano-Lopez, Alfredo
    Climente-Alarcon, Vicente
    Garin-Abellan, Carlos
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [2] Reliable Detection of Rotor Winding Asymmetries in Wound Rotor Induction Motors via Integral Current Analysis
    Antonino-Daviu, Jose
    Quijano-Lopez, Alfredo
    Climente-Alarcon, Vicente
    Garin-Abellan, Carlos
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) : 2040 - 2048
  • [3] Application of Transient Analysis to Detect Rotor and Stator Asymmetries in Wound Rotor Induction Motors: a Field Case
    Antonino-Daviu, Jose A.
    Zamudio-Ramirez, Israel
    Osornio-Rios, Roque A.
    Dunai, Larisa
    Quijano-Lopez, Alfredo
    2021 IEEE WORKSHOP ON ELECTRICAL MACHINES DESIGN, CONTROL AND DIAGNOSIS (WEMDCD), 2021, : 237 - 242
  • [4] Bispectrum Analysis of Stray Flux Signals for the Robust Detection of Winding Asymmetries in Wound Rotor Induction Motors
    Iglesias-Martinez, Miguel E.
    Fernandez de Cordoba, Pedro
    Alfonso Antonino-Daviut, Jose
    Conejero, J. Alberto
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4485 - 4490
  • [5] Tracking of High-Order Stray-Flux Harmonics Under Starting for the Detection of Winding Asymmetries in Wound-Rotor Induction Motors
    Zamudio-Ramirez, Israel
    Antonino-Daviu, Jose A.
    Osornio-Rios, Roque A.
    Dunai, Larisa
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (08) : 8463 - 8471
  • [6] Parameter Estimation of Wound-Rotor Induction Motors From Transient Measurements
    Kojooyan-Jafari, Hengameh
    Monjo, Lluis
    Corcoles, Felipe
    Pedra, Joaquin
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2014, 29 (02) : 300 - 308
  • [7] NEW CONTROLLER FOR WOUND-ROTOR INDUCTION MOTORS
    GREY, JC
    POTTHOFF, EO
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1967, 39 (01): : 105 - &
  • [8] DYNAMIC BRAKING OF WOUND-ROTOR INDUCTION MOTORS WITHOUT EXTERNAL SUPPLY.
    Bolt, T.A.
    Holectechniek, 1974, 4 (01): : 16 - 21
  • [9] Leakage flux saturation effects on the transient performance of wound-rotor induction motors
    Jabr, Hany A.
    Kar, Narayan C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (07) : 1280 - 1289
  • [10] Detection of rotor faults via transient analysis of the external magnetic field
    Antonino-Daviu, Jose
    Razik, Hubert
    Quijano-Lopez, Alfredo
    Climente-Alarcon, Vicente
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 3815 - 3821