EXAMINATION OF SEASONAL ENERGY EFFICIENCY RATIO AND ECONOMICAL ANALYSIS OF ROOM AIR CONDITIONER

被引:0
|
作者
Zhang Furen [1 ]
Zeng Xiaoyan [1 ]
Zhang Hui [1 ]
机构
[1] Chongqing Jiaotong Univ, Sch Mech & Elect Engn, Chongqing 400074, Peoples R China
关键词
Room air Conditioner; two-compressor; seasonal efficiency ratio; experiment; analysis and evaluation;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Enthalpy-difference method has been utilized in this paper to test and analyze Seasonal Energy Efficiency Ratio (SEER) of normal model air conditioner and two-compressor model air conditioner with same refrigeration ability. According to test data, and combining the weather data of 6 cities, the energy efficiency of each product has been gotten in this paper. It shows that the average energy saving rate and average cost saving rate of these six cities of two-compressor air conditioner of these six cities is 22.12% and 6.29%, respectively, when compared with air conditioner with constant rotate speed.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [31] Operation and energy efficiency of a hybrid air conditioner simultaneously connected to the grid and to photovoltaic panels
    Aguilar, Francisco J.
    Quiles, Pedro V.
    Aledo, Simon
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2013), 2014, 48 : 768 - 777
  • [32] Consumer valuations of energy efficiency investments: The case of Vietnam's Air Conditioner market
    Matsumoto, Shigeru
    Omata, Yukiko
    [J]. JOURNAL OF CLEANER PRODUCTION, 2017, 142 : 4001 - 4010
  • [33] Experimental analysis of an air conditioner powered by photovoltaic energy and supported by the grid
    Aguilar, F. J.
    Aledo, S.
    Quiles, P. V.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 123 : 486 - 497
  • [34] Effect on Thermal Comfort and Energy Consumption of Different Installation Height and Supply Air Angle of Room Air Conditioner by Simulation
    Yang, Zixu
    Wang, Baolong
    Shi, Wenxing
    Li, Xianting
    [J]. INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,
  • [35] A CFD analysis of room aspect ratio on the effect of buoyancy and room air flow
    Tripathi, Brajesh
    Moulic, Sandipan Ghosh
    Arora, R. C.
    [J]. THERMAL SCIENCE, 2007, 11 (04): : 79 - 94
  • [36] Analysis of Seasonal Exergy Efficiency of an Air Handling Unit
    Streckiene, G.
    Martinaitis, V.
    Bielskus, J.
    [J]. 2ND INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND SMART MATERIALS (ICEESM 2017), 2017, 1884
  • [37] Method to control an air conditioner by directly measuring the relative humidity of indoor air to improve the comfort and energy efficiency
    Lim, Dae Kyu
    Ahn, Byoung Ha
    Jeong, Ji Hwan
    [J]. APPLIED ENERGY, 2018, 215 : 290 - 299
  • [38] DEVELOPMENT OF HIGH EFFICIENCY AND LOW NOISE CROSS-FLOW FANS FOR ROOM AIR CONDITIONER INDOOR UNIT
    Yamakawa, Hironobu
    [J]. PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING - 2014, VOL 1B: SYMPOSIA, 2014,
  • [39] A framework for short-term energy consumption prediction based on room air conditioner group characteristics
    Xue, Kai
    Liu, Meng
    Ma, Mingjun
    Hu, Mengqiang
    Yan, Lu
    Chen, Xiaoyi
    Zeng, Wenmao
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [40] Comparative analysis of the energy efficiency of air-conditioner and variable refrigerant flow systems in residential buildings in the Yangtze River region
    Xiao, Hansong
    Yang, Zixu
    Shi, Wenxing
    Wang, Baolong
    Li, Baizhan
    Song, Qiang
    Li, Jinbo
    Xu, Zhenkun
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 55