EXAMINATION OF SEASONAL ENERGY EFFICIENCY RATIO AND ECONOMICAL ANALYSIS OF ROOM AIR CONDITIONER

被引:0
|
作者
Zhang Furen [1 ]
Zeng Xiaoyan [1 ]
Zhang Hui [1 ]
机构
[1] Chongqing Jiaotong Univ, Sch Mech & Elect Engn, Chongqing 400074, Peoples R China
关键词
Room air Conditioner; two-compressor; seasonal efficiency ratio; experiment; analysis and evaluation;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Enthalpy-difference method has been utilized in this paper to test and analyze Seasonal Energy Efficiency Ratio (SEER) of normal model air conditioner and two-compressor model air conditioner with same refrigeration ability. According to test data, and combining the weather data of 6 cities, the energy efficiency of each product has been gotten in this paper. It shows that the average energy saving rate and average cost saving rate of these six cities of two-compressor air conditioner of these six cities is 22.12% and 6.29%, respectively, when compared with air conditioner with constant rotate speed.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [2] The optimized match method enhances the energy efficiency ratio (EER) of room air-conditioner
    Wang Zhiyuan
    Hetao
    Xu Zhiliang
    Luohao
    Dang Hongchang
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [3] Data-driven assessment of room air conditioner efficiency for saving energy
    Wang, Weiqi
    Zhou, Zixuan
    Lu, Zhongming
    [J]. JOURNAL OF CLEANER PRODUCTION, 2022, 338
  • [4] EFFECT OF INNER COMPRESSION RATIO ADJUSTMENT ON SEASONAL ENERGY PERFORMANCE OF INVERTER AIR CONDITIONER
    Wang Baolong
    Jiang An
    Shi Wenxing
    Li Xianting
    [J]. BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 1515 - 1522
  • [5] Energy conservation opportunity for room air conditioner in Malaysia
    Masjuki, HH
    Choudhury, IA
    Mahlia, TMI
    Rahman, S
    [J]. WREC'99: WORLD RENEWABLE ENERGY CONGRESS'99 MALAYSIA, PROCEEDINGS, 1999, : 431 - 435
  • [6] Energy analysis and optimization about room conditioner
    Zhu, PG
    Yu, WP
    Zhang, XS
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 479 - 484
  • [8] Energy conservation and thermal environment analysis of room air conditioner with intermittent supply airflow
    Fan, Yunqing
    Toyoshima, Masaki
    Saito, Makoto
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2018, 13 (01) : 84 - 91
  • [9] Potential CO2 reduction by implementing energy efficiency standard for room air conditioner in Malaysia
    Mahlia, TMI
    Masjuki, HH
    Choudhury, IA
    Saidur, R
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (14) : 1673 - 1685
  • [10] METHOD FOR CALCULATING ENERGY-CONSUMPTION OF A ROOM AIR CONDITIONER
    BEARD, WL
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1976, 18 (12): : 42 - 42