Silicon photomultiplier modules for MRI-compatible PET

被引:3
|
作者
Sul, Woo-Suk [1 ]
Kim, Hyoungtaek [2 ]
Cho, Gyuseong [2 ]
机构
[1] Natl NanoFab Ctr, Daejeon, South Korea
[2] Korea Adv Inst Sci & Technol, Daejeon 305701, South Korea
来源
关键词
Photon detectors for UV; visible and IR photons (solid-state) (PIN diodes; APDs; SiPMTs; G-APDs; CCDs; EBCCDs; EMCCDs etc); Solid state detectors; Gamma camera; SPECT; PET PET/CT coronary CT angiography (CTA); Multi-modality systems;
D O I
10.1088/1748-0221/10/04/C04002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon photomultiplier (SiPM) modules were developed for use in positron emission tomography-magnetic resonance imaging (PET-MRI), which is a hybrid medical imaging technology. A PET-MRI is very efficient in the early diagnosis of representative senile diseases, including cancer, Alzheimer's disease, and Parkinson's disease. SiPMs comprise the core image sensor for MR-compatible PET applications since they have a low operational voltage, high gain, good timing resolution, ruggedness, insensitivity to magnetic fields, compactness, and low cost. In PET systems, SiPM microcells can be optimized by making a trade-off between photon detection efficiency (PDE) and dynamic range. The SiPM modules used in this study were fabricated at the National NanoFab Center (NNFC) of South Korea by using a customized CMOS processes. The SiPM modules were evaluated by first packaging them with a cost-effective PCB package instead of with a conventional ceramic package. Measurements on 1,400 SiPMs indicated a uniform breakdown voltage of 20.54 V with a standard deviation of 0.07 V. Moreover, the SiPM modules present a high and uniform energy resolution of 13.6% with a standard deviation of 0.5% at 511 keV with 3 x 3 x 20 mm(3) cerium-doped lutetium-yttrium oxyorthosilicate (Lu2(1-x) Y2xSiO5:Ce, LYSO) crystal coupling. These results indicated that the proposed devices offer adequate performance to form the foundation of an image sensor technology for MRI-compatible PET.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Development of a sterilizable MRI-compatible manipulator for stereotactic neurosurgery
    Nakamura, R
    Masamune, K
    Nishikawa, Y
    Kobayashi, E
    Sakuma, I
    Dohi, T
    Iseki, H
    Takakura, K
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 1019 - 1019
  • [42] Effect of radiofrequency (RF) shielding in a silicon-photomultiplier PET/MRI system
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Kanai, Yasukazu
    Shimosegawa, Eku
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [43] MRI-Compatible Injection System for Magnetic Microparticle Embolization
    Li, Ning
    Michaud, Francois
    Nosrati, Zeynab
    Loghin, Dumitru
    Tremblay, Charles
    Plantefeve, Rosalie
    Saatchi, Katayoun
    Hafeli, Urs O.
    Martel, Sylvain
    Soulez, Gilles
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (08) : 2331 - 2340
  • [44] Functional MRI-Compatible Laparoscopic Surgery Training Simulator
    Bahrami, Parisa
    Schweizer, Tom A.
    Tam, Fred
    Grantcharov, Teodor P.
    Cusimano, Michael D.
    Graham, Simon J.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (03) : 873 - 881
  • [45] MRI-COMPATIBLE FIDUCIAL MARKERS FOR PROSTATE CANCER PATIENTS
    Bol, G.
    van der Heide, U.
    Kotte, A.
    van Vulpen, M.
    Lagendijk, J.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S374 - S374
  • [46] Design and Fabrication of an MRI-Compatible, Autonomous Incubation System
    Khalilzad-Sharghi, Vahid
    Xu, Huihui
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (10) : 2406 - 2415
  • [47] MRI-Compatible and Conformal Electrocorticography Grids for Translational Research
    Fallegger, Florian
    Schiavone, Giuseppe
    Pirondini, Elvira
    Wagner, Fabien B.
    Vachicouras, Nicolas
    Serex, Ludovic
    Zegarek, Gregory
    May, Adrien
    Constanthin, Paul
    Palma, Marie
    Khoshnevis, Mehrdad
    Van Roost, Dirk
    Yvert, Blaise
    Courtine, Gregoire
    Schaller, Karl
    Bloch, Jocelyne
    Lacour, Stephanie P.
    ADVANCED SCIENCE, 2021, 8 (09)
  • [48] Development of an MRI-Compatible Device for Prostate Focal Therapy
    Cepek, Jeremy
    Chronik, Blaine
    Lindner, Uri
    Trachtenberg, John
    Fenster, Aaron
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 455 - 462
  • [49] MRI-Compatible Hydraulic Drive Needle Insertion Robot
    Qiu, Yufu
    Wu, Longfei
    Huang, Fang
    Huang, Zhifeng
    Yan, Qiusheng
    Guo, Jing
    2021 6TH IEEE INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM 2021), 2021, : 86 - 92
  • [50] Design of an Wearable MRI-Compatible Hand Exoskeleton Robot
    Liu, Kun
    Hasegawa, Yasuhisa
    Saotome, Kousaku
    Sainkai, Yosiyuki
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2017, PT I, 2017, 10462 : 242 - 250