Wide dynamic-range beam-profile instrumentation for a beam-halo measurement: Description and operation

被引:0
|
作者
Gilpatick, JD [1 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
D O I
暂无
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Within the halo experiment conducted at the Low Energy Demonstration Accelerator (LEDA) at LANL, specific beam instruments that acquire horizontally and vertically projected particle-density distributions out to > 100000: 1 dynamic range are located throughout the 52-magnet halo lattice. We measured the core of the distributions using traditional wire scanners, and the tails of the distributions using water-cooled graphite scraping devices. The wire scanner and halo scrapers are mounted on the same moving frame whose location is controlled with stepper motors. A sequence within the Experimental Physics and Industrial Control System (EPICS) software communicates with a National Instruments LabVIEW virtual instrument to control the motion and location of the scanner/scraper assembly. Secondary electrons from the wire scanner 0.033-mm carbon wire and protons impinging on the scraper are both detected with a lossy-integrator electronic circuit. Algorithms implemented within EPICS and in Research System's Interactive Data Language subroutines analyze and plot the acquired distributions. This paper describes the beam instrument and our experience with its operation.
引用
收藏
页码:122 / 125
页数:4
相关论文
共 50 条
  • [31] Conducting single-transverse-mode operation with a wide tuning range in commercial multimode VCSELs by beam-profile-adapted optical feedback
    Hsu, Chuan-Pi
    Cheng, Da-Long
    Kuo, Wang-Chuang
    Yen, Tsu-Chiang
    OPTICS LETTERS, 2009, 34 (18) : 2861 - 2863
  • [32] MEASUREMENT SYSTEM FOR ALPHA-AEROSOLS AND BETA-AEROSOLS WITH WIDE DYNAMIC-RANGE AND KR-85 MASKING
    KREINER, HJ
    TIGGEMANN, H
    WICHMANN, HP
    KERNTECHNIK, 1989, 54 (04) : 255 - 257
  • [33] WIDE-RANGE LASER-BEAM DIAMETER MEASUREMENT USING A PERIODIC EXPONENTIAL GRATING
    AWWAL, AAS
    SMITH, JA
    BELLOTO, J
    BHARATRAM, G
    OPTICS AND LASER TECHNOLOGY, 1991, 23 (03): : 159 - 161
  • [34] Synchrotron radiation interferometry for beam size measurement at low current and in large dynamic range
    Li, Wei
    Yan, Jun
    Liu, Peifan
    Wu, Ying K.
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2022, 25 (08)
  • [35] A Larae Dynamic Range Charge Measurement ASIC Family for Beam Monitoring in Radiotherapy Applications
    Mazza, G.
    La Rosa, A.
    Attili, A.
    Bourhaleb, F.
    Cirio, R.
    Donetti, M.
    Garella, A.
    Givechi, N.
    Giordanengo, S.
    Marchetto, F.
    Monaco, V.
    Pardo, J.
    Pecka, A.
    Peroni, C.
    Russo, G.
    Sacchi, R.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 352 - 355
  • [36] Focused cylindrical vector beam assisted microscopic pSPR biosensor with an ultra wide dynamic range
    Wang, Rong
    Zhang, Chonglei
    Yang, Yong
    Zhu, Siwei
    Yuan, X. -C.
    OPTICS LETTERS, 2012, 37 (11) : 2091 - 2093
  • [37] HIGH DYNAMIC-RANGE SIMS DEPTH PROFILING ON INSITU ION-BEAM-GENERATED MESAS USING THE ION-MICROSCOPE
    GILLEN, G
    SURFACE AND INTERFACE ANALYSIS, 1992, 18 (11) : 777 - 780
  • [38] Compact laser beam analyzer with polarization independent optics and wide dynamic range of neutral density adjustment
    Scaggs, Michael
    Haas, Gil
    LASER RESONATORS, MICRORESONATORS, AND BEAM CONTROL XV, 2013, 8600
  • [39] Development of wide dynamic range beam loss monitor system for J-PARC main ring
    Satou, K.
    Toyama, T.
    Kamikubota, N.
    Yamada, S.
    Yoshida, S.
    8TH INTERNATIONAL PARTICLE ACCELERATOR CONFERENCE (IPAC 2017), 2017, 874
  • [40] DEVELOPMENT OF A CURRENT MONITOR SYSTEM FOR MEASURING PULSED-BEAM CURRENT OVER A WIDE DYNAMIC RANGE.
    Gallegos, F.R.
    Morrison, L.J.
    Browman, A.A.
    IEEE Transactions on Nuclear Science, 1985, NS-32 (05)