Optimization of Sensor Resolution for Standoff Chemical Detection

被引:0
|
作者
Broadwater, Joshua [1 ]
Carr, Alison [1 ]
机构
[1] Johns Hopkins Univ, Appl Phys Lab, Laurel, MD 20723 USA
关键词
sensor resolution; FTIR sensors; chemical detection; IDENTIFICATION;
D O I
10.1117/12.819266
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Fourier transform infrared spectroscopy is a standard technique for remote detection of gaseous vapors. However, as algorithms mature and hyperspectral imaging in the longwave infrared becomes more prominent in ground based applications it is important to determine optimum parameters for detection due to potentially high data rates. One parameter, spectral resolution, is of particular interest because 1) it can be easily changed and 2) it has significant effect on the data rate. The following presents a mathematical foundation for determining the spectral resolution for vapor detection in the presence of atmospheric interferants such as water vapor and ozone. Results are validated using real-world long wave infrared hyperspectral data of several open air chemical simulant releases.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Standoff chemical detection using quantum cascade lasers and photoacoustic sensing techniques
    Chen, Xing
    Janssen, Douglas
    Kostov, Dan
    Choa, Fow-Sen
    2011 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2011,
  • [42] Standoff detection of chemical and biological threats using miniature widely tunable QCLs
    Kotidis, Petros
    Deutsch, Erik R.
    Goyal, Anish
    MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS VII, 2015, 9467
  • [43] Development and testing of a hyper-spectral imaging instrument for standoff chemical detection
    Chamberland, M
    Farley, V
    Giroux, J
    Villemaire, A
    Legault, JF
    Schwantes, K
    CHEMICAL AND BIOLOGICAL STANDOFF DETECTION II, 2004, 5584 : 135 - 143
  • [44] Recent advances in the passive standoff detection of chemical vapours by differential FTIR radiometry
    Lavoie, H
    Puckrin, E
    Thériault, JM
    Bouffard, F
    Dubé, D
    Chemical and Biological Sensing VI, 2005, 5795 : 96 - 105
  • [45] Broadband mid-IR frequency comb source for standoff chemical detection
    Vodopyanov, Konstantin L.
    MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS VII, 2015, 9467
  • [46] Highly sensitive standoff detection and identification of traces of explosives and of biological and chemical agents
    Portnov, Alexander
    Bar, Ilana
    Rosenwaks, Salman
    OPTICS AND PHOTONICS FOR COUNTERTERRORISM AND CRIME FIGHTING VI AND OPTICAL MATERIALS IN DEFENCE SYSTEMS TECHNOLOGY VII, 2010, 7838
  • [47] Threat detection using a standoff, wide-area hyperspectral Raman imaging sensor
    Gomer, Nathaniel R.
    Lamsal, Nirmal
    Sun, Haiyin
    Nelson, Matthew P.
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIX, 2018, 10629
  • [48] Technology assessment of passive millimeter wave imaging sensor for standoff airborne mine detection
    Blume, B
    Taylor, S
    Albers, J
    Witherspoon, NH
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS II, 1997, 3079 : 600 - 613
  • [49] A Small, Low Cost, Hyperspectral Imaging FTIR Sensor Design for Standoff Detection Applications
    Gruber, Thomas, Jr.
    Moore, Brad
    Tercha, Brian
    Bowe, Ryan
    NEXT-GENERATION SPECTROSCOPIC TECHNOLOGIES V, 2012, 8374
  • [50] One-handed UV Raman sensor for standoff trace detection now a reality
    Waterbury, Rob
    Conghuyentonnu, Thuyan
    Hardy, Hunter
    Jacobson, Alex
    Molner, Tim
    Robins, Ryan
    Scott, Marshall
    Smolski, Viktor
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES, CBRNE SENSING XXV, 2024, 13056