Designing an effective intravenous membrane oxygenator requires selecting hollow fiber membranes (HFMs) that present minimal resistance to gas exchange over extended periods of time. Microporous fiber membranes, as used in extracorporeal oxygenators, offer a minimal exchange resistance, but one that diminishes with time because of fiber wetting and subsequent serum leakage. Potentially attractive alternatives are composite HFMs, which inhibit fiber wetting and serum leakage by incorporating a true membrane layer within their porous walls. To evaluate composite and other HFMs, the authors developed a simple apparatus and method for measuring HFM permeability in a gas-liquid system under conditions relevant to intravenous oxygenation. The system requires only a small volume of liquid that is mixed with a pitched blade impeller driven by a direct current motor at controlled rates. Mass flux is measured from the gas flow exiting the fibers, eliminating the necessity of measuring any liquid side conditions. The authors measured the CO2 exchange permeabilities of Mitsubishi MHF 200L composite HFMs, KPF 280E microporous HFMs, and KPF 190 microporous HFMs. The membrane permeabilities to CO2 were 9.3 x 10(-5) ml/cm(2)/sec/cmHg for the MHF 200L fiber, 4.7 x 10(-4) ml/cm(2)/sec/cmHg for the KPF 280E fiber, and 2.8 x 10(-4) ml/cm(2)/sec/cmHg for the KPF 190 fiber. From these results it is concluded that 1) because of liquid-fiber surface interactions, the permeabilities of the microporous fibers are several orders of magnitude less than would be measured for completely gas filled pores, emphasizing the importance of measuring microporous fiber permeability in a gas-liquid system; and 2) the liquid diffusional boundary layer adjacent to the fibers generated by the pitched blade impeller is unique to each fiber, resulting in different boundary layer characterizations.
引用
收藏
页码:M446 / M451
页数:6
相关论文
共 50 条
  • [31] Preparation and characterization of PVDF-montmorillonite mixed matrix hollow fiber membrane for gas-liquid contacting process
    Rezaei, M.
    Ismail, A. F.
    Hashemifard, S. A.
    Matsuura, T.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2014, 92 (11): : 2449 - 2460
  • [32] MEASURING SYSTEM AND METHOD OF DETERMINING THE FLOW-RATE OF COMPONENTS IN A GAS-LIQUID FLOW
    BRAGO, EN
    MEASUREMENT TECHNIQUES USSR, 1991, 34 (11): : 1148 - 1151
  • [33] AN ULTRASOUND-CONDUCTIVITY METHOD FOR MEASURING GAS HOLDUP IN A MICROBUBBLE-BASED GAS-LIQUID SYSTEM
    Weng, Liangyu
    Zhang, Jinzhao
    Zhang, Wen-Hui
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2018, 96 (04): : 1005 - 1011
  • [34] Experimental method to determine anisotropic permeability of hollow fiber membrane bundles
    Schlanstein, Peter C.
    Limper, Alexander
    Hesselmann, Felix
    Schmitz-Rode, Thomas
    Steinseifer, Ulrich
    Arens, Jutta
    JOURNAL OF MEMBRANE SCIENCE, 2018, 546 : 70 - 81
  • [35] Chemical dynamic method for measuring kLa in gas-liquid dispersions
    Havelka, P
    Moucha, T
    Sinkule, J
    Linek, V
    CHEMICAL ENGINEERING COMMUNICATIONS, 1998, 168 : 97 - 110
  • [36] CO2 REMOVAL BY HOLLOW-FIBER GAS-LIQUID CONTACTOR
    NISHIKAWA, N
    ISHIBASHI, M
    OHTA, H
    AKUTSU, N
    MATSUMOTO, H
    KAMATA, T
    KITAMURA, H
    ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (6-9) : 415 - 418
  • [37] Effect of PVDF concentration on the morphology and performance of hollow fiber membrane employed as gas-liquid membrane contactor for CO2 absorption
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Duidar, Ali
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 98 : 174 - 185
  • [38] A method for measuring the size distribution and the local gas concentration in gas-liquid flows
    A. P. Belousov
    P. Ya. Belousov
    Optoelectronics, Instrumentation and Data Processing, 2008, 44 (2) : 131 - 134
  • [39] PERFORMANCE OF HOLLOW FIBER MEMBRANE GAS-LIQUID CONTACTORS TO ABSORB CO2 USING DIETHANOLAMINE (DEA) AS A SOLVENT
    Kartohardjono, Sutrasno
    Nata, Pan Ade
    Prasetio, Eko
    Yuliusman
    MAKARA JOURNAL OF TECHNOLOGY, 2009, 13 (02): : 86 - 90
  • [40] A Method for Measuring the Size Distribution and the Local Gas Concentration in Gas-Liquid Flows
    Belousov, A. P.
    Belousov, P. Ya.
    OPTOELECTRONICS INSTRUMENTATION AND DATA PROCESSING, 2008, 44 (02) : 131 - 134