Three-dimensional ultrasound is an accurate and reproducible technique for fetal crown-rump length measurement

被引:7
|
作者
Youssef, Aly [1 ]
Salsi, Ginevra [1 ]
Bellussi, Federica [1 ]
Arcangeli, Tiziana [1 ]
Farina, Antonio [1 ]
Contro, Elena [1 ]
Maroni, Elisa [1 ]
Pilu, Gianluigi [1 ]
Rizzo, Nicola [1 ]
Ghi, Tullio [1 ]
机构
[1] Univ Bologna, St Orsola Malpighi Univ Hosp, Dept Obstet & Gynecol, I-40138 Bologna, Italy
关键词
TRIMESTER; BIOMETRY;
D O I
10.1002/pd.2931
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Objective The aim of the study was to evaluate the accuracy and reproducibility of fetal crown-rump length (CRL) measurement using three-dimensional ultrasound (3DUS). Methods We included a series of women with singleton pregnancy at 6-13 + 6 weeks. Following CRL measurement by the two-dimensional ultrasound (2DUS), a 3DUS volume was acquired. On the reconstructed midsagittal plane, CRL was measured twice by an operator and once by another. The correlation between CRL measured by 3DUS and 2DUS, as well as the intraobserver and interobserver agreement, was then calculated. Furthermore, the agreement between 2DUS and 3DUS CRL measurements together with intraobserver and interobserver agreement was calculated separately for the groups with a midsagittal acquisition plane (MSAP) and non-midsagittal acquisition plane (NMSAP). Results Overall, 137 pregnancies were included in the analysis. CRL measurements performed using 3DUS showed excellent correlation with 2DUS [intraclass correlation coefficient (ICC) = 0.992]. In addition, the 3DUS showed a high intraobserver and interobserver agreement (ICC = 0.999 and 0.993, respectively). Finally, when we divided the acquired volumes according to the plane of acquisition, excellent 2DUS-3DUS, as well as intraobserver and interobserver agreement, was maintained for both MSAP and NMSAP. Conclusion 3DUS is a highly accurate and reproducible tool for fetal CRL measurement regardless of the fetal position at the time of 3D volume acquisition. (C) 2012 John Wiley & Sons, Ltd.
引用
下载
收藏
页码:220 / 227
页数:8
相关论文
共 50 条
  • [41] ULTRASONIC BIOMETRY OF THE FETAL CROWN-RUMP LENGTH BETWEEN 7 AND 20 WEEKS GESTATION
    HANSMANN, M
    SCHUHMACHER, H
    FOEBUS, J
    GEBURTSHILFE UND FRAUENHEILKUNDE, 1979, 39 (08) : 656 - 666
  • [43] Comparison of Fetal Crown-Rump Length Measurements between Thawed and Fresh Embryo Transfer
    Mitta, Kyriaki
    Tsakiridis, Ioannis
    Giougi, Evaggelia
    Mamopoulos, Apostolos
    Kalogiannidis, Ioannis
    Dagklis, Themistoklis
    Athanasiadis, Apostolos
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (09)
  • [44] The Application of Crown-Chin Length to Crown-Rump Length Ratio in Predicting Fetal Skeletal Dysplasia at First Trimester
    Li, Yingsi
    Zhou, Hang
    Yang, Xin
    Li, Dongzhi
    Can, Liao
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (10) : 2497 - 2504
  • [45] Fetal gender and sonographic assessment of crown-rump length: implications for multifetal pregnancy reduction
    Becker, S
    Ural, S
    Fehm, T
    Bienstock, J
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 24 (04) : 399 - 401
  • [46] Prediction of fetal loss by first-trimester crown-rump length in IVF pregnancies
    Gabbay-Benziv, Rinat
    Dolev, Amir
    Bardin, Ron
    Meizner, Israel
    Fisch, Benjamin
    Ben-Haroush, Avi
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2017, 295 (03) : 771 - 775
  • [47] Intertwin crown-rump length discordance in the prediction of fetal anomalies, fetal loss and adverse perinatal outcome
    Grande, Maribel
    Gonce, Anna
    Stergiotou, Iosifina
    Bennasar, Mar
    Borrell, Antoni
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (17): : 2883 - 2888
  • [48] The significance of crown-rump length measurement for predicting adverse pregnancy outcome of threatened abortion
    Reljic, M
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 17 (06) : 510 - 512
  • [49] Systematic review of the methodology used for creating dating charts based on fetal crown-rump length
    Napolitano, R.
    Dhami, J.
    Ohuma, E.
    Ioannou, C.
    Kennedy, S.
    Villar, J.
    Papageorghiou, A. T.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2013, 120 : 94 - 94
  • [50] Correlation of first-trimester fetal crown-rump length with outcome of pregnancy and birth weight
    Vafaei, Homeira
    Samsami, Alamtaj
    Zolghadri, Jaleh
    Hosseini-Nohadani, Azam
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2012, 119 (02) : 141 - 144