Midterm Results of a Contemporary, Porous-Coated Acetabular System in Patients Undergoing Primary Total Hip Replacement for Degenerative Hip Disease: A Prospective, Multicenter Study

被引:3
|
作者
Wilson, Ian R. [1 ,2 ]
Turgeon, Thomas R. [1 ,2 ]
Gascoyne, Trevor C. [2 ,3 ]
Della Valle, Craig J. [4 ]
McCalden, Richard W. [5 ]
机构
[1] Concordia Joint Replacement Grp, Winnipeg, MB, Canada
[2] Univ Manitoba, Dept Surg Orthopaed, Winnipeg, MB, Canada
[3] Orthopaed Innovat Ctr, Winnipeg, MB, Canada
[4] Rush Univ, Dept Orthopaed Surg, Med Ctr, Chicago, IL 60612 USA
[5] Western Univ, Dept Surg Orthopaed, London, ON, Canada
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 07期
关键词
R3; total hip replacement; total hip arthroplasty; revision; porous coated; midterm results; 10-YEAR FOLLOW-UP; HIGH FAILURE RATE; RANDOMIZED-TRIAL; UNITED-STATES; ARTHROPLASTY; COMPONENT; CUP; POLYETHYLENE; OSTEONECROSIS; IRRADIATION;
D O I
10.1016/j.arth.2020.02.068
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A contemporary, porous-coated acetabular implant designed for uncemented insertion was introduced in Europe and Australia in 2007. A similar previous acetabular system was found in several studies at 10 to 15-year follow-up to demonstrate accelerated polyethylene wear, osteolysis, and early failure. The current study was conducted to determine the midterm safety and effectiveness of this contemporary acetabular system using highly crosslinked polyethylene and ceramic liners at 5-year follow-up. Methods: A prospective, nonrandomized study was conducted at 8 sites in Canada and the United States. All 148 study participants received a contemporary acetabular shell with proprietary porous coating. The primary outcome was the requirement for revision surgery at 5 years postoperatively. Secondary outcomes included a survival analysis, patient-reported outcome measures, radiographic failure, and postoperative adverse events. Results: At 5-year follow-up there was 1 cup revised for deep infection. No cups were revised for loosening and none were found to be radiographically loose. The overall survival rate with reoperation for any reason was 97.1%. The success rate was 96.8% for polyethylene and 100% for ceramic with no difference in the success rate between either bearing surface (P = 1.0). The mean patient-reported outcome measures all improved significantly between preoperative and 5-year postoperative scores (P < .001). Conclusion: Results from this 5-year, multicenter, prospective study indicate excellent survivorship for this acetabular system when used with crosslinked polyethylene or ceramic bearing surfaces. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1862 / 1867
页数:6
相关论文
共 50 条
  • [41] Effect of Coronal and Sagittal Spinal Malalignment on Spinopelvic Mobility in Patients Undergoing Total Hip Replacement A Prospective Observational Study
    Haffer, Henryk
    Wang, Zhen
    Hu, Zhouyang
    Muellner, Maximilian
    Hipfl, Christian
    Pumberger, Matthias
    CLINICAL SPINE SURGERY, 2022, 35 (06): : E510 - E519
  • [42] A prospective randomized study on the use of nadroparin calcium in the prophylaxis of thromboembolism in Korean patients undergoing elective total hip replacement
    Yoo, MC
    Kang, CS
    Kim, YH
    Kim, SK
    INTERNATIONAL ORTHOPAEDICS, 1997, 21 (06) : 399 - 402
  • [43] Physical Activity Behavior of Patients 1 Year After Primary Total Hip Arthroplasty: A Prospective Multicenter Cohort Study
    Wagenmakers, Robert
    Stevens, Martin
    Groothoff, Johan W.
    Zijlstra, Wiebren
    Bulstra, Sjoerd K.
    van Beveren, Jan
    van Raaij, Jos J. A. M.
    van den Akker-Scheek, Inge
    PHYSICAL THERAPY, 2011, 91 (03): : 373 - 380
  • [44] THE POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS, INSERTED WITHOUT CEMENT - RESULTS AFTER 5 TO 7 YEARS IN A PROSPECTIVE-STUDY (VOL 75A, PG 77, 1993)
    HEEKIN
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05): : 791 - 791
  • [45] Ten year results of the collum femoris preserving total hip replacement: a prospective cohort study of seventy five patients
    Hutt, Jonathan
    Harb, Ziad
    Gill, Ian
    Kashif, Fadhil
    Miller, John
    Dodd, Matthew
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (05) : 917 - 922
  • [46] Primary uncemented total hip arthroplasty in patients &lt;40 years old -: 10- to 14-year results using first-generation proximally porous-coated implants
    Duffy, GP
    Berry, DJ
    Rowland, C
    Cabanela, ME
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 140 - 144
  • [47] Ten year results of the collum femoris preserving total hip replacement: a prospective cohort study of seventy five patients
    Jonathan Hutt
    Ziad Harb
    Ian Gill
    Fadhil Kashif
    John Miller
    Matthew Dodd
    International Orthopaedics, 2014, 38 : 917 - 922
  • [48] A PROSPECTIVE-STUDY ON INTERMITTENT PNEUMATIC COMPRESSION IN THE PREVENTION OF DEEP-VEIN THROMBOSIS IN PATIENTS UNDERGOING TOTAL HIP OR TOTAL KNEE REPLACEMENT
    PIDALA, MJ
    DONOVAN, DL
    KEPLEY, RF
    SURGERY GYNECOLOGY & OBSTETRICS, 1992, 175 (01): : 47 - 51
  • [49] Cerebrospinal fluid cholinergic biomarkers are associated with postoperative delirium in elderly patients undergoing Total hip/knee replacement: a prospective cohort study
    Lin, Xu
    Tang, Jiaming
    Liu, Chen
    Li, Xiaoxuan
    Cao, Xipeng
    Wang, Bin
    Dong, Rui
    Xu, Wei
    Yu, Xinjuan
    Wang, Mingshan
    Bi, Yanlin
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [50] Cerebrospinal fluid cholinergic biomarkers are associated with postoperative delirium in elderly patients undergoing Total hip/knee replacement: a prospective cohort study
    Xu Lin
    Jiaming Tang
    Chen Liu
    Xiaoxuan Li
    Xipeng Cao
    Bin Wang
    Rui Dong
    Wei Xu
    Xinjuan Yu
    Mingshan Wang
    Yanlin Bi
    BMC Anesthesiology, 20