The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients

被引:264
|
作者
Cowger, Jennifer [1 ]
Pagani, Francis D. [2 ]
Haft, Jonathan W. [2 ]
Romano, Matthew A. [2 ]
Aaronson, Keith D. [1 ]
Kolias, Theodore J. [1 ]
机构
[1] Univ Michigan Hlth Syst, Div Cardiovasc Med, Ann Arbor, MI USA
[2] Univ Michigan Hlth Syst, Sect Cardiac Surg, Ann Arbor, MI USA
基金
美国国家卫生研究院;
关键词
heart-assist devices; heart failure; valves; risk factors; PULSE PRESSURE; FLOW; FUSION; VALVE; LOCATION; WALL;
D O I
10.1161/CIRCHEARTFAILURE.109.917765
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Aortic insufficiency (AI) following left ventricular assist device (LVAD) placement can affect device performance. The aim of this study was to examine AI development following LVAD implantation. Methods and Results-Echocardiograms (n=315) from 78 subjects undergoing HeartMate-XVE (n=25 [32%]) or HeartMate-II (n=53 [68%]) implantations from 2004 to 2008 were reviewed. Studies were obtained preoperatively and at 1, 3, 6, 12, 18, and 24 months after surgery. AI was graded on an interval scale (0=none, 0.5=trivial, 1=mild, 1.5=mild-moderate, 2=moderate, 2.5=moderate-severe, 3=severe), and the change in AI at follow-up was analyzed with significance tests. Kaplan-Meier estimates for freedom from moderate or worse AI at follow-up were generated. Mixed-model linear regression was used to identify correlates of AI progression during LVAD support. The median (25th, 75th percentile) duration of LVAD support was 239 (112, 455) days, and preoperative AI grade was 0.0 (0.0, 0.0). At 6 months, 89 +/- 4% of subjects (n=49 at risk) were free from moderate or worse AI, but this was reduced to 74 +/- 7% (n=29 at risk) and 49 +/- 13% (n=13 at risk) by 12 and 18 months, respectively. Correlates (slope +/- SE) of AI progression included female sex (0.002 +/- 0.001; P=0.01), smaller body surface area (-0.003 +/- 0.001 per m(2); P=0.0017), and HeartMate-II model type (0.002 +/- 0.001; P=0.039). Correlates (beta +/- SE) of progressive AI on postoperative echocardiogram included increasing aortic sinus diameter (0.04 +/- 0.01 per mm; P=0.001), an aortic valve that remained closed (0.42 +/- 0.06; P < 0.001) or only intermittently opened (0.34 +/- 0.09; P < 0.001), and lower left ventricular diastolic (-0.002 +/- 0.0004 per cm(3); P < 0.001) and systolic (-0.002 +/- 0.0004 per cm3; P < 0.001) volumes. Conclusions-AI progresses over time in LVAD-supported patients. As we move toward an era of long-term cardiac support, more studies are needed to determine the clinical significance of these findings. (Circ Heart Fail.2010;3:668-674.)
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [41] Aortic Valve Pathology in Patients Supported by a Continuous-Flow Left Ventricular Assist Device
    Saito, T.
    Potapov, E.
    Wassilew, K.
    Gorodetski, B.
    Krabatsch, T.
    Hetzer, R.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S195 - S195
  • [42] Aortic Valve Pathology in Patients Supported by Continuous-Flow Left Ventricular Assist Device
    Saito, Tomohiro
    Wassilew, Katharina
    Gorodetski, Boris
    Stein, Julia
    Falk, Volkmar
    Krabatsch, Thomas
    Potapov, Evgenij
    [J]. CIRCULATION JOURNAL, 2016, 80 (06) : 1371 - 1377
  • [43] Transcatheter Aortic Valve Replacement for Left Ventricular Assist Device-Induced Aortic Insufficiency
    Kozarek, Katherine
    Minhaj, Mohammed M.
    Chaney, Mark A.
    D'Ancona, Giuseppe
    Pasic, Miralem
    Carrel, Thierry
    Cotter, Elizabeth Healy
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (04) : 1982 - 1990
  • [44] LEFT VENTRICULAR ASSIST DEVICE PUMP SPEED, AORTIC VALVE CLOSURE AND INCIDENCE OF AORTIC INSUFFICIENCY
    Mukunda, Neha
    Birati, Edo Y.
    Johnson, Bryce V.
    Wald, Joyce
    Atluri, Pavan
    Goldberg, Lee
    Urgo, Kimberly
    Rao, Sriram D.
    Genuardi, Michael
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 749 - 749
  • [45] Quality of life for patients supported on a left ventricular assist device
    MacIver, Jane
    Rao, Vivek
    Ross, Heather J.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2011, 8 (03) : 325 - 337
  • [46] Modified Central Closure Technique for Treatment of Aortic Insufficiency in Patients on Left Ventricular Assist Device Support
    Morgan, Jeffrey A.
    Brewer, Robert J.
    [J]. ASAIO JOURNAL, 2012, 58 (06) : 626 - 628
  • [47] Transcatheter Aortic Valve Replacement and Surgical Aortic Valve Replacement Outcomes in Left Ventricular Assist Device Patients with Aortic Insufficiency
    Rali, Aniket S.
    Taduru, Siva S.
    Tran, Lena E.
    Ranka, Sagar
    Schlendorf, Kelly H.
    Barker, Colin M.
    Shah, Ashish S.
    Lindenfeld, Joann
    Zalawadiya, Sandip K.
    [J]. CARDIAC FAILURE REVIEW, 2022, 8
  • [48] Development of De-Novo Aortic Insufficiency in Patients with Durable Left Ventricular Assist Device Who Were Bridged from Impella Device
    Mody, K. P.
    Stewart, S. M.
    Walters, P.
    Silva, C.
    Anderson, M. B.
    Batsides, G. P.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S471 - S471
  • [49] Axial Flow Left Ventricular Assist Device is Associated with Progression of Aortic Valve Insufficiency
    Masood, M. F.
    Fischer, I.
    Kotkar, K.
    Ewald, G. A.
    Silvestry, S. C.
    Balsara, K. R.
    Itoh, A.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S284 - S285
  • [50] Left ventricular assist device support of medically unresponsive pulmonary hypertension and aortic insufficiency
    Adamson, RM
    Dembitsky, WP
    Jaski, BE
    Daily, PO
    Moreno, R
    Kim, JC
    Sono, J
    Akasaka, T
    Hoagland, PM
    Gordon, JB
    [J]. ASAIO JOURNAL, 1997, 43 (04) : 365 - 369