Fault Investigation and Analysis of an Overhead Transmission Line Vibration Damper

被引:2
|
作者
Hickey, Conor [1 ]
Young, Paul [1 ]
Mayomi, Tolulope [2 ]
Noctor, Jason [2 ]
机构
[1] Dublin City Univ, Sch Mech & Mfg Engn, Dublin, Ireland
[2] ESB Engn & Major Projects, Networks Engn, Overhead Line Design, Dublin, Ireland
关键词
Vibration Damper; Transmission Line; Fault Investigation; Aeolian Vibration; Computational Modelling;
D O I
10.1109/UPEC50034.2021.9548196
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the findings from an investigation into the probable cause of damage to vibration dampers found on an existing 110 kV overhead transmission line in the midlands of Ireland. The vibration dampers were positioned on an earthwire and they were found damaged at twelve separate spans along the overhead line. The purpose of this investigation was to establish the main factors which may cause the messenger cable of the vibration damper to deform based on knowledge gained on the characteristics of the overhead line in question, literature review, inspection of the removed dampers and line, and computational analysis. The fatigue characteristics of overhead line conductors, the influence of conductor sag-tension characteristics and conductor windinduced motions were all factors that have been considered. A fault investigation was designed in two parts. The first part performed by the Electricity Supply Board (ESB) in Ireland, involved modelling the existing line and measuring the vibration response of the line. Part two, conducted by Dublin City University (DCU) involved performing computational modelling to determine the serviceability of the damaged dampers and to validate the findings of the initial fault investigation.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Influence of wind vibration of overhead transmission tower-line system on ice shedding
    Zhang, R. (zhangrufang@cqu.edu.cn), 1600, Science Press (40):
  • [42] ANALYSIS OF ELECTRIC FIELD IN 330 kV OVERHEAD TRANSMISSION LINE
    Deltuva, Ramunas
    Virbalis, Juozapas Arvydas
    Zebrauskas, Stasys
    ELECTRICAL AND CONTROL TECHNOLOGIES, 2011, : 255 - 259
  • [43] Theoretical Analysis and Countermeasures on Iced Galloping of Overhead Transmission Line
    Shang, Q. H.
    Cheng, Y. F.
    Liu, B.
    Zhao, B.
    Yang, J. L.
    Zhang, L. C.
    Zhan, X. P.
    Li, P.
    2016 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY, ENVIRONMENT AND INFORMATION ENGINEERING (SEEIE 2016), 2016, : 542 - 547
  • [44] Fault location for overhead and cable hybrid DC line based on the energy transmission characteristics
    Zhang, Yanxia
    Li, Ting
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 221
  • [45] Fault location for overhead and cable hybrid transmission line in VSC-HVDC system
    Zhang, Yanxia
    Li, Ting
    Wang, Jian
    Wang, Haidong
    Chang, Yuqing
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 195
  • [46] INVESTIGATION OF TRANSIENT INDUCED VOLTAGE TO A COMMUNICATION LINE FROM AN OVERHEAD POWER TRANSMISSION-LINE
    IMAMURA, T
    AMETANI, A
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1990, 137 (02) : 129 - 138
  • [47] DISCUSSION OF MATHEMATICAL ANALYSIS OF TRANSMISSION LINE VIBRATION
    HARD, AR
    RICHARDS.AS
    POFFENBE.JC
    SCANLAN, RH
    SWART, RL
    KOMENDA, RA
    CLAREN, R
    DIANA, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1969, PA88 (12): : 1767 - &
  • [48] Analysis of one-line ground fault surge on simulated overhead distribution line
    Kikuchi, T
    Yoshimi, M
    Hikosaka, T
    Matsumoto, T
    ELECTRICAL ENGINEERING IN JAPAN, 1997, 118 (01) : 52 - 60
  • [49] Sensitivity analysis of transmission line fault location
    Zivanovic, Rastko
    Ooi, Hoong Boon
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1187 - 1190
  • [50] An investigation of induced voltages to an underground gas pipeline from an overhead transmission line
    Isogai, Hiroshi
    Ametani, Akihiro
    Hosokawa, Yuji
    ELECTRICAL ENGINEERING IN JAPAN, 2008, 164 (01) : 43 - 51