Influence of target dose heterogeneity on dose sparing of normal tissue in peripheral lung tumor stereotactic body radiation therapy

被引:5
|
作者
Wei, Zhigong [1 ]
Peng, Xingchen [1 ]
Wang, Yan [2 ]
Yang, Lianlian [1 ]
He, Ling [1 ]
Liu, Zheran [1 ]
Wang, Jingjing [1 ]
Mu, Xiaoli [1 ]
Li, Ruidan [1 ]
Xiao, Jianghong [3 ]
机构
[1] Sichuan Univ, West China Hosp, Canc Ctr, Dept Biotherapy, Chengdu, Sichuan, Peoples R China
[2] Sichuan Univ, Sch Comp Sci, Chengdu 610000, Sichuan, Peoples R China
[3] Sichuan Univ, West China Hosp, Canc Ctr, Dept Radiat Oncol, 37 Guoxue Alley, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Dose heterogeneity; Dose sparing; Stereotactic body radiation therapy; Volumetric-modulated arc therapy; LOCATED EARLY-STAGE; ABLATIVE RADIOTHERAPY; POOLED ANALYSIS; CANCER; TOXICITY; TRIAL; CHEMORADIOTHERAPY; CONSTRAINTS; GUIDELINE;
D O I
10.1186/s13014-021-01891-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective To evaluate the influence of target dose heterogeneity on normal tissue dose sparing for peripheral lung tumor stereotactic body radiation therapy (SBRT). Methods Based on the volumetric-modulated arc therapy (VMAT) technique, three SBRT plans with homogeneous, moderate heterogeneous, and heterogeneous (HO, MHE, and HE) target doses were compared in 30 peripheral lung tumor patients. The prescription dose was 48 Gy in 4 fractions. Ten rings outside the PTV were created to limit normal tissue dosage and evaluate dose falloff. Results When MHE and HE plans were compared to HO plans, the conformity index of the PTV was increased by approximately 0.08. The median mean lung dose (MLD), V-5, V-10, V-20 of whole lung, D-2%, D-1cc, D-2cc of the rib, V-30 of the rib, D-2% and the maximum dose (D-max) of the skin, and D-2% and D-max of most mediastinal organs at risk (OARs) and spinal cord were reduced by up to 4.51 Gy or 2.8%. Analogously, the median D-max, D-2% and mean dose of rings were reduced by 0.71 to 8.46 Gy; and the median R-50% and D-2cm were reduced by 2.1 to 2.3 and 7.4% to 8.0%, respectively. Between MHE and HE plans there was little to no difference in OARs dose and dose falloff beyond the target. Furthermore, the dose sparing of rib V-30 and the mean dose of rings were negatively correlated with the rib and rings distance from tumor, respectively. Conclusions For peripheral lung tumor SBRT, target conformity, normal tissue dose, and dose falloff around the target could be improved by loosening or abandoning homogeneity. While there was negligible further dose benefit for the maximum target dose above 125% of the prescription, dose sparing of normal tissue derived from a heterogeneous target decreased as the distance from the tumor increased.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Maximum PTV Dose Predicts for Radiation Pneumonitis Following Lung Stereotactic Body Radiation Therapy
    Stauder, M. C.
    Olivier, K. R.
    Macdonald, O. K.
    Lafata, K.
    Mayo, C. S.
    Bauer, H. J.
    Miller, R. C.
    Brown, P. D.
    Garces, Y. I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S614 - S614
  • [32] DOSE-VOLUME ANALYSIS OF RADIATION LUNG INJURY AFTER STEREOTACTIC BODY RADIATION THERAPY
    Masciullo, S.
    Masi, L.
    Casamassima, F.
    Menichelli, C.
    Bonucci, I.
    Doro, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 : S44 - S44
  • [33] Radiation-induced Rib Fracture After Hypofractionated Stereotactic Body Radiation Therapy for Patients With Peripheral Lung Tumor: Impact of the Maximum Dose and the Fraction Size
    Aoki, M.
    Sato, M.
    Narita, Y.
    Hirose, K.
    Kawaguchi, H.
    Hatayama, Y.
    Takai, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S568 - S568
  • [34] The Effects of Interplay on Accumulated Dose in High-Dose-Rate Stereotactic Body Radiation Therapy of Lung Cancer
    Watkins, W.
    Song, W. Y.
    Hugo, G. D.
    Weiss, E.
    Siebers, J. V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S758 - S758
  • [35] A Dose Falloff Gradient Study in RapidArc Planning of Lung Stereotactic Body Radiation Therapy
    Narayanasamy, Ganesh
    Desai, Dharmin
    Maraboyina, Sanjay
    Penagaricano, Jose
    Zwicker, Robert
    Johnson, Ellis Lee
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (03) : 147 - 154
  • [36] Accumulated Dose Investigation of Respiratory Gated Stereotactic Body Radiation Therapy for Lung Tumors
    Wu, J.
    Betzing, C.
    Srisuthep, A.
    Fuss, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S866 - S866
  • [37] Lung dose constraints for normo-fractionated radiotherapy and for stereotactic body radiation therapy
    Blais, E.
    Pichon, B.
    Mampuya, A.
    Antoine, M.
    Lagarde, P.
    Kantor, G.
    Breton-Callu, C.
    Lefebvre, C.
    Gerard, M.
    Aamarcha, A.
    Ozsahin, M.
    Bourhis, J.
    Maingon, P.
    Troussier, I.
    Pourel, N.
    CANCER RADIOTHERAPIE, 2017, 21 (6-7): : 584 - 596
  • [38] Dosimetric evaluation of target dose in stereotactic body radiation therapy (SBRT) of lung using a dynamic motion anthropomorphic phantom
    Rassiah, P
    Tanyi, J
    Cheng, C
    Varchena, V
    Fuss, M
    Salter, B
    MEDICAL PHYSICS, 2004, 31 (06) : 1880 - 1880
  • [39] Simultaneous tumour dose escalation and liver sparing in stereotactic body radiation therapy (SBRT) of liver tumours
    Molinelli, S.
    De Pooter, J.
    Romero, A. Mendez
    Wunderink, W.
    Cattaneo, G. M.
    Calandrino, R.
    Heijmen, B.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S101 - S101
  • [40] Dose Sparing to Normal Brain Tissue for Stereotactic Radiosurgery Utilizing Negative Margins
    Baker, J.
    Gibb, J.
    Ailawadi, S.
    Hsia, A.
    Han, J.
    Kim, J.
    Xu, Z.
    Ryu, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3607 - 3607