Importance of the characteristics of the chromatographic separation in HPLC for the interpretation of HbA1c assay in the presence of a variant hemoglobin

被引:1
|
作者
Guillard, Emmanuelle [1 ]
Jaisson, Stephane [1 ]
Gillery, Philippe [1 ]
机构
[1] CHU Reims, Lab Biol & Rech Pediat, Reims, France
关键词
HPLC; HbA(1c); hemoglobinopathy; PRESSURE LIQUID-CHROMATOGRAPHY; GLYCATED HEMOGLOBIN; ANALYZER;
D O I
10.1684/abc.2010.0472
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The methods of HbA(1c) assay using ion exchange high pressure liquid chromatography (HPLC) allow the detection of the most common hemoglobin variants. This observation highlights the different behaviour of two HPLC analyzers in the presence of Tatras hemoglobin. By one of the analyzer (Variant II, Bio-Rad) this variant is detected, but not by the other (G8, Tosoh Biosciences). As HbA(1c) result is crucial for the therapeutic decision, it is important that biologists know the characteristics of the method they use, in order to detect the possible occurence of an hemoglobinopathy and to ensure the best interpretation of the result.
引用
收藏
页码:598 / 602
页数:5
相关论文
共 50 条
  • [41] Evaluation of an improved HPLC HbA1c method
    Higgins, T. N.
    Holmes, D.
    Vu, R.
    Tanaka, S.
    Sivaraman, P.
    CLINICAL BIOCHEMISTRY, 2008, 41 (03) : 192 - 192
  • [42] Influence of Hemoglobin Strasbourg, a Rare High Oxygen Affinity Hemoglobin Variant, on Different Methods of HbA1c Measurement
    Wagner, Marcus
    Stoffel-Wagner, Birgit
    Zur, Berndt
    HEMOGLOBIN, 2024, 48 (03) : 209 - 211
  • [43] Haemoglobin Kenitra detected by HPLC assay and its compromising effect on the measurement of HbA1c
    Molina-Arrebola, M. -A.
    Sanchez-Crespo, A.
    Gimenez Lopez, M. -J.
    Estevez-Escobar, M.
    Garcia-Bautista, J. -A.
    Perez-Moyano, R.
    Salas-Coronas, J.
    Avivar-Oyonarte, C.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 (06) : E18 - E20
  • [44] Verification of the interchangeability of glycosylated hemoglobin results (% HBA1C) by high performance liquid chromatography (HPLC)
    Tejedor Ganduxe, X.
    Minchinela Girona, J.
    Granada Ibern, M.
    Martinez De Osaba, J. Barallat
    Leis Sestao, A.
    Martinez Iribarren, A.
    Morales Indiano, C.
    Llopis Diaz, M.
    CLINICA CHIMICA ACTA, 2019, 493 : S659 - S659
  • [45] HB UBE-2 variant hemoglobin case detected during HBA1C measurement
    Kocaturk, Evin
    Kiraz, Zeynep Kusku
    Demir, Sukru Saygin
    Cilingir, Oguz
    Teke, Hava Uskudar
    Alatas, Ibrahim Ozkan
    CUKUROVA MEDICAL JOURNAL, 2021, 46 (02): : 866 - 868
  • [46] Detection of hemoglobin variant HbS on the basis of discrepant HbA1c values in different measurement methods
    Takeda Y.
    Kawanami D.
    Utsunomiya K.
    Diabetology International, 2016, 7 (2) : 199 - 203
  • [47] Biological variation components of glycated hemoglobin HbA1c on tosoh G7 HPLC
    Ercan, Mujgan
    Avci, Esin
    Akbulut, Emis Deniz
    Oguz, Esra Firat
    Topcuoglu, Canan
    Yucel, Cigdem
    Abusoglu, Sedat
    Turhan, Turan
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2018, 9 (06) : 469 - 473
  • [48] TITRATION OF GLYCOSYLATED HEMOGLOBIN HBA1C BY CHROMATOGRAPHY LIQUID
    GUYON, F
    POTIER, M
    COIGNET, MC
    ANNALES DE BIOLOGIE CLINIQUE, 1988, 46 (02) : 116 - 118
  • [49] GLYCATED HEMOGLOBIN (HBA1C) AS AN INDICATOR OF JOB STRAIN
    NETTERSTROM, BO
    SJOL, A
    STRESS MEDICINE, 1991, 7 (02): : 113 - 118
  • [50] Hemoglobin J-Iran (HBB c.232C>G): Interference with the assay of HbA1c
    Kurtoglu, Aysegul Ugur
    Eren, Esin
    Erkal, Ozgur
    Kurtoglu, Erdal
    Yilmaz, Necat
    CLINICA CHIMICA ACTA, 2017, 465 : 80 - 81