Comparison of robotic-assisted and manual implantation of a primary total hip replacement - A prospective study

被引:145
|
作者
Honl, M [1 ]
Dierk, O [1 ]
Gauck, C [1 ]
Carrero, V [1 ]
Lampe, F [1 ]
Dries, S [1 ]
Quante, M [1 ]
Schwieger, K [1 ]
Hille, E [1 ]
Morlock, MM [1 ]
机构
[1] Barmbek Gen Hosp, Dept Orthopaed Surg, D-22307 Hamburg, Germany
来源
关键词
D O I
10.2106/00004623-200308000-00007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Robotic-assisted total hip replacement has become a common method of implantation, especially in Europe. It frequently has been postulated that robotic reaming would result in an improved clinical outcome due to the better fit of the prosthesis, but that has never been demonstrated in a prospective study, to our knowledge. The purpose of this study was to compare robotic-assisted implantation of a total hip replacement with conventional manual implantation. Methods: One hundred and fifty-four patients scheduled for total hip replacement were randomly assigned to undergo either conventional manual implantation of an S-ROM prosthesis (eighty patients) or robotic-assisted implantation of such a prosthesis (seventy-four patients). The five-axis ROBODOC was used for the robotic-assisted procedures. Pre-operatively as well as at three, six, twelve, and twenty-four months after surgery, the scores according to the Harris and Merle d'Aubigne systems and the Mayo clinical score were determined. Radiographs made at these intervals were analyzed for evidence of loosening, prosthetic alignment, and heterotopic ossification. Results: Thirteen (18%) of the seventy-four attempted robotic implantations had to be converted to manual implantations as a result of failure of the system. The duration of the robotic procedures was longer than that of the manual procedures (mean and standard deviation,107.1 +/- 29.1 compared with 82.4 +/- 23.4 minutes, p < 0.001). Limb-length equality (mean discrepancy, 0.18 +/- 0.30 compared with 0.96 +/- 0.93 cm, p < 0.001) and varus-valgus orientation of the stem (mean angle between the femur and the shaft of the prosthesis, 0.34degrees +/- 0.67degrees compared with 0.84degrees +/- 1.23degrees, p < 0.001) were better after the robotic procedures. At six months, slightly more heterotopic ossification was seen in the group treated with robotic implantation. The group treated with robotic implantation had a better Mayo clinical score at six and twelve months and a better Harris score at twelve months; however, by twenty-four months, no difference was found between the groups with regard to any of the three scores. Dislocation was more frequent in the group treated with robotic implantation: it occurred in eleven of the sixty-one patients in that group compared with three of eighty in the other group (p < 0.001). Recurrent dislocation and pronounced limping were indications for revision surgery in eight of the sixty-one patients treated with robotic implantation compared with none of the seventy-eight (excluding two with revision for infection) treated with manual insertion (p < 0.001). Rupture of the gluteus medius tendon was observed during all of the revision operations. Conclusions: The robotic-assisted technology had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure. Disadvantages were the high revision rate; the amount of muscle damage, which we believe was responsible for the higher dislocation rate; and the longer duration of surgery. This technology must be further developed before its widespread usage can be justified. Level of Evidence: Therapeutic study, Level I-1a (randomized controlled trial [significant difference]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1470 / 1478
页数:9
相关论文
共 50 条
  • [31] Improved perioperative narcotic usage patterns in patients undergoing robotic-assisted compared to manual total hip arthroplasty
    Buchan, Graham B. J.
    Bernhard, Zachary
    Hecht, Christian J.
    Davis, Graeme A.
    Pickering, Trevor
    Kamath, Atul F.
    ARTHROPLASTY, 2023, 5 (01)
  • [32] Comparative Cost Analysis of Robotic-Assisted and Jig-Based Manual Primary Total Knee Arthroplasty
    Cotter, Eric J.
    Wang, Jesse
    Illgen, Richard L.
    JOURNAL OF KNEE SURGERY, 2022, 35 (02) : 176 - 184
  • [33] Does acetabular robotic-assisted total hip arthroplasty with femoral navigation improve clinical outcomes at 1-year post-operative? A case-matched propensity score study comparing 98 robotic-assisted versus 98 manual implantation hip arthroplasties
    Coulomb, Remy
    Cascales, Valentin
    Haignere, Vincent
    Bauzou, Francois
    Kouyoumdjian, Pascal
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (01)
  • [34] Lengths of Stay and Discharge Dispositions after Total Knee Arthroplasty: A Comparison of Robotic-Assisted and Manual Techniques
    Archer, Allison
    Salem, Hytham S.
    Coppolecchia, Andrea
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2023, 36 (04) : 404 - 410
  • [35] Robotic-Assisted Total Hip Arthroplasty in Patients Who Have Developmental Hip Dysplasia
    Hepinstall, Matthew
    Mota, Frank
    Muthusamy, Nishanth
    Naylor, Brandon
    Salem, Hytham S.
    Coden, Gloria
    Mont, Michael A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 39
  • [36] Assessment of accuracy of an imageless hand-held robotic-assisted system in component positioning in total knee replacement: a prospective study
    Narendra Vaidya
    Tanmay N. Jaysingani
    Taufiq Panjwani
    Rakesh Patil
    Ajinkya Deshpande
    Abhinav Kesarkar
    Journal of Robotic Surgery, 2022, 16 : 361 - 367
  • [37] Assessment of accuracy of an imageless hand-held robotic-assisted system in component positioning in total knee replacement: a prospective study
    Vaidya, Narendra
    Jaysingani, Tanmay N.
    Panjwani, Taufiq
    Patil, Rakesh
    Deshpande, Ajinkya
    Kesarkar, Abhinav
    JOURNAL OF ROBOTIC SURGERY, 2022, 16 (02) : 361 - 367
  • [38] Comparison of manual rasping and robotic milling for short metaphyseal-fitting stem implantation in total hip arthroplasty: a cadaveric study
    Lim, Seung-Jae
    Kim, Sang-Min
    Lim, Byung-Ho
    Moon, Young-Wan
    Park, Youn-Soo
    COMPUTER AIDED SURGERY, 2013, 18 (1-2) : 33 - 40
  • [39] Comparison of Postoperative Instability and Acetabular Cup Positioning in Robotic-Assisted Versus Traditional Total Hip Arthroplasty
    Shaw, Jonathan H.
    Rahman, Tahsin M.
    Wesemann, Luke D.
    Jiang, Charles Z.
    Lindsay-Rivera, Kevin G.
    Davis, Jason J.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (08): : S881 - S889
  • [40] Initial stability of cementless acetabular cups using robotic-assisted total hip arthroplasty compared with the conventional manual technique: An in vitro biomechanical study
    Hidaka, Ryo
    Matsuda, Kenta
    Mochizuki, Hidetaka
    Kawano, Hirotaka
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (01):