Process monitoring using PCA-based GLR methods: A comparative study

被引:15
|
作者
Sheriff, M. Ziyan [1 ,2 ]
Karim, M. Nazmul [2 ]
Nounou, Hazem N. [3 ]
Nounou, Mohamed N. [1 ]
机构
[1] Texas A&M Univ Qatar, Chem Engn Program, Doha, Qatar
[2] Texas A&M Univ, Artie McFerrin Dept Chem Engn, College Stn, TX 77843 USA
[3] Texas A&M Univ Qatar, Elect & Comp Engn Program, Doha, Qatar
关键词
Principal component analysis; Generalized likelihood ratio; Fault detection; Statistical process monitoring; Hypothesis testing; Tennessee Eastman process; FAULT-DETECTION; MULTISCALE PCA; DESIGN;
D O I
10.1016/j.jocs.2018.05.013
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Statistical process monitoring is a key requirement for many industrial processes. Many of these processes utilize Principal Component Analysis (PCA) in order to carry out statistical process monitoring due to its computational simplicity. Two fault detection charts that are commonly used with the PCA method are the Hotelling T-2 and Qstatistics. Although these charts are reasonably able to detect most shifts in the process mean, they may be unable to accurately detect other process faults, such as shifts in the process variance. Hypothesis testing methods such as the Generalized Likelihood Ratio (GLR) chart have been developed in order to detect different types of deviations from normal operating conditions, i.e., process faults. Although, GLR charts have shown superior performance in terms of fault detection compared to other existing techniques, literature has only examined the performance of a PCA-based GLR chart designed to detect shifts in the mean. Through a simulated synthetic example, this work evaluates the performance of PCA-based GLR charts designed to independently detect a shift in the mean, independently detect a shift in the variance, and simultaneously detect shifts in the mean and/or variance. The results show that in order to detect a shift in the mean or a shift in the variance, the GLR charts designed to independently detect either type of fault need to be implemented in parallel as they provide significantly lower missed detection rates, than a GLR chart designed to detect shifts in both the process mean and variance simultaneously. The GLR chart designed to simultaneously detect both a shift in the mean and variance does not perform as well as the other GLR charts, since two parameters (both the mean and variance) need to be estimated for this method while maximizing the GLR statistic, as opposed to just a single parameter for the other GLR charts. The practical applicability of the PCA-based GLR charts is demonstrated through the well-known benchmark Tennessee Eastman process, and through a case where autocorrelation is present in the data. Therefore, in order to detect shifts in the mean and/or variance, we recommend parallel implementation of the GLR charts designed to independently detect shifts in the mean, and independently detect shifts in the variance Parallel implementation of these two GLR charts aids with fault classification as well. This work also discusses the importance of selecting an appropriate window length of previous data to be used when computing the maximum likelihood estimates (MLEs) and maximizing the GLR statistic, keeping all fault detection criteria in mind in order to ensure that the desired fault detection results are obtained. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 246
页数:20
相关论文
共 50 条
  • [41] A PCA-based PCM data analyzing method for diagnosing process failures
    Yan, Liren
    IEEE TRANSACTIONS ON SEMICONDUCTOR MANUFACTURING, 2006, 19 (04) : 404 - 410
  • [42] Exploring Dataset Similarities using PCA-based Feature Selection
    Siegert, Ingo
    Boeck, Ronald
    Wendemuth, Andreas
    Vlasenko, Bogdan
    2015 INTERNATIONAL CONFERENCE ON AFFECTIVE COMPUTING AND INTELLIGENT INTERACTION (ACII), 2015, : 387 - 393
  • [43] PCA-Based Visual Servoing Using Optical Coherence Tomography
    Dahroug, Bassem
    Tamadazte, Brahim
    Andreff, Nicolas
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (02): : 3430 - 3437
  • [44] Skin color detection using PCA-based color representation
    Kim, Sungyoung
    Ko, Jaepil
    Ko, Jaepil, 1600, Science and Engineering Research Support Society (09): : 231 - 242
  • [45] Comparative Study of Two Hardware Development Boards for Implementation of PCA-based Algorithms in Structural Damage Detection
    Camacho-Navarro, Jhonatan
    Ruiz, Magda L.
    Perez-Gamboa, Oscar
    Villamizar-Mejia, Rodolfo
    Mujica, Luis E.
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 1173 - 1180
  • [46] PCA-based walking engine using motion capture data
    Glardon, P
    Boulic, R
    Thalmann, D
    COMPUTER GRAPHICS INTERNATIONAL, PROCEEDINGS, 2004, : 292 - 298
  • [47] Improved Methods for PCA-Based Reconstructions: Case Study Using the Steig et al. (2009) Antarctic Temperature Reconstruction
    O'Donnell, Ryan
    Lewis, Nicholas
    McIntyre, Steve
    Condon, Jeff
    JOURNAL OF CLIMATE, 2011, 24 (08) : 2099 - 2115
  • [48] Process monitoring based on probabilistic PCA
    Kim, DS
    Lee, IB
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 67 (02) : 109 - 123
  • [49] Improving Scalability of Cloud Monitoring Through PCA-Based Clustering of Virtual Machines
    Canali, Claudia
    Lancellotti, Riccardo
    JOURNAL OF COMPUTER SCIENCE AND TECHNOLOGY, 2014, 29 (01) : 38 - 52
  • [50] PCA-based filtering of temperature effect on impedance monitoring in prestressed tendon anchorage
    Thanh-Canh Huynh
    Dang, Ngoc-Loi
    Kim, Jeong-Tae
    SMART STRUCTURES AND SYSTEMS, 2018, 22 (01) : 57 - 70