Process monitoring using PCA-based GLR methods: A comparative study

被引:15
|
作者
Sheriff, M. Ziyan [1 ,2 ]
Karim, M. Nazmul [2 ]
Nounou, Hazem N. [3 ]
Nounou, Mohamed N. [1 ]
机构
[1] Texas A&M Univ Qatar, Chem Engn Program, Doha, Qatar
[2] Texas A&M Univ, Artie McFerrin Dept Chem Engn, College Stn, TX 77843 USA
[3] Texas A&M Univ Qatar, Elect & Comp Engn Program, Doha, Qatar
关键词
Principal component analysis; Generalized likelihood ratio; Fault detection; Statistical process monitoring; Hypothesis testing; Tennessee Eastman process; FAULT-DETECTION; MULTISCALE PCA; DESIGN;
D O I
10.1016/j.jocs.2018.05.013
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Statistical process monitoring is a key requirement for many industrial processes. Many of these processes utilize Principal Component Analysis (PCA) in order to carry out statistical process monitoring due to its computational simplicity. Two fault detection charts that are commonly used with the PCA method are the Hotelling T-2 and Qstatistics. Although these charts are reasonably able to detect most shifts in the process mean, they may be unable to accurately detect other process faults, such as shifts in the process variance. Hypothesis testing methods such as the Generalized Likelihood Ratio (GLR) chart have been developed in order to detect different types of deviations from normal operating conditions, i.e., process faults. Although, GLR charts have shown superior performance in terms of fault detection compared to other existing techniques, literature has only examined the performance of a PCA-based GLR chart designed to detect shifts in the mean. Through a simulated synthetic example, this work evaluates the performance of PCA-based GLR charts designed to independently detect a shift in the mean, independently detect a shift in the variance, and simultaneously detect shifts in the mean and/or variance. The results show that in order to detect a shift in the mean or a shift in the variance, the GLR charts designed to independently detect either type of fault need to be implemented in parallel as they provide significantly lower missed detection rates, than a GLR chart designed to detect shifts in both the process mean and variance simultaneously. The GLR chart designed to simultaneously detect both a shift in the mean and variance does not perform as well as the other GLR charts, since two parameters (both the mean and variance) need to be estimated for this method while maximizing the GLR statistic, as opposed to just a single parameter for the other GLR charts. The practical applicability of the PCA-based GLR charts is demonstrated through the well-known benchmark Tennessee Eastman process, and through a case where autocorrelation is present in the data. Therefore, in order to detect shifts in the mean and/or variance, we recommend parallel implementation of the GLR charts designed to independently detect shifts in the mean, and independently detect shifts in the variance Parallel implementation of these two GLR charts aids with fault classification as well. This work also discusses the importance of selecting an appropriate window length of previous data to be used when computing the maximum likelihood estimates (MLEs) and maximizing the GLR statistic, keeping all fault detection criteria in mind in order to ensure that the desired fault detection results are obtained. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 246
页数:20
相关论文
共 50 条
  • [1] Enhanced Monitoring using PCA-based GLR Fault Detection and Multiscale Filtering
    Harrou, Fouzi
    Nounou, Mohamed N.
    Nounou, Hazem N.
    PROCEEDINGS OF THE 2013 IEEE SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE IN CONTROL AND AUTOMATION (CICA), 2013, : 1 - 8
  • [2] Statistical fault detection using PCA-based GLR hypothesis testing
    Harrou, Fouzi
    Nounou, Mohamed N.
    Nounou, Hazem N.
    Madakyaru, Muddu
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2013, 26 (01) : 129 - 139
  • [3] A modified PCA-based approach for process monitoring
    Zhang, Jingxin
    Chen, Hao
    Cai, Pinlong
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 3011 - 3016
  • [4] Process monitoring of iron-making process in a blast furnace with PCA-based methods
    Zhou, Bo
    Ye, Hao
    Zhang, Haifeng
    Li, Mingliang
    CONTROL ENGINEERING PRACTICE, 2016, 47 : 1 - 14
  • [5] Detecting Abnormal Ozone Levels using PCA-based GLR Hypothesis Testing
    Harrou, Fouzi
    Nounou, Mohamed N.
    Nounou, Hazem N.
    2013 IEEE SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DATA MINING (CIDM), 2013, : 95 - 102
  • [6] Automated interpretation of PCA-based process monitoring and fault diagnosis using signed digraphs
    Vedam, H
    Venkatasubramanian, V
    ON-LINE FAULT DETECTION AND SUPERVISION IN THE CHEMICAL PROCESS INDUSTRIES 1998, 1998, : 219 - 223
  • [7] Fault detection behavior analysis of PCA-based process monitoring approach
    Wang, Haiqing
    Song, Zhihuan
    Wang, Hui
    2002, Chemical Industry Press (53):
  • [8] THE USE OF ADAPTIVE PCA-BASED CONDITION MONITORING METHODS IN MACHINING PROCESSES
    Grasso, Marco
    Colosimo, Bianca Maria
    Moroni, Giovanni
    PROCEEDINGS OF THE ASME 11TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, VOL 4, 2012, : 133 - 140
  • [9] Graphical enhancement to support PCA-based process monitoring and fault diagnosis
    Ralston, P
    DePuy, G
    Graham, JH
    ISA TRANSACTIONS, 2004, 43 (04) : 639 - 653
  • [10] Evaluation of diagnosis methods in PCA-based Multivariate Statistical Process Control
    Fuentes-Garcia, Marta
    Macia-Fernandez, Gabriel
    Camacho, Jose
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2018, 172 : 194 - 210