Facilitating Applications of SSVEP-Based BCIs by Within-Subject Information Transfer

被引:1
|
作者
Liu, Xiaobing [1 ]
Liu, Bingchuan [2 ]
Dong, Guoya [1 ]
Gao, Xiaorong [2 ]
Wang, Yijun [3 ,4 ]
机构
[1] Hebei Univ Technol, Sch Hlth Sci & Biomed Engn, State Key Lab Reliabil & Intelligence Elect Equipm, Hebei Key Lab Bioelectromagnet & Neural Engn, Tianjin, Peoples R China
[2] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing, Peoples R China
[3] Chinese Acad Sci, Inst Semicond, State Key Lab Integrated Optoelect, Beijing, Peoples R China
[4] Chinese Inst Brain Res, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
brain-computer interface; steady-state visual evoked potential; electroencephalography; transfer learning; cross day; cross electrode; PERFORMANCE;
D O I
10.3389/fnins.2022.863359
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The steady-state visual evoked potential based brain-computer interface (SSVEP-BCI) can provide high-speed alternative and augmentative communication in real-world applications. For individuals using a long-term BCI, within-subject (i.e., cross-day and cross-electrode) transfer learning could improve the BCI performance and reduce the calibration burden. To validate the within-subject transfer learning scheme, this study designs a 40-target SSVEP-BCI. Sixteen subjects are recruited, each of whom has performed experiments on three different days and has undergone the experiments of the SSVEP-BCIs based on the dry and wet electrodes. Several transfer directions, including the cross-day directions in parallel with the cross-electrode directions, are analyzed, and it is found that the transfer learning-based approach can maintain stable performance by zero training. Compared with the fully calibrated approaches, the transfer learning-based approach can achieve significantly better or comparable performance in different transfer directions. This result verifies that the transfer learning-based scheme is well suited for implementing a high-speed zero-training SSVEP-BCI, especially the dry electrode-based SSVEP-BCI system. A validation experiment of the cross-day wet-to-dry transfer, involving nine subjects, has shown that the average accuracy is 85.97 +/- 5.60% for the wet-to-dry transfer and 77.69 +/- 6.42% for the fully calibrated method with dry electrodes. By leveraging the electroencephalography data acquired on different days by different electrodes via transfer learning, this study lays the foundation for facilitating the long-term usage of the SSVEP-BCI and advancing the frontier of the dry electrode-based SSVEP-BCI in real-world applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
    Lin, Zhonglin
    Zhang, Changshui
    Wu, Wei
    Gao, Xiaorong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (06) : 1172 - 1176
  • [22] A Canonical Correlation Analysis-Based Transfer Learning Framework for Enhancing the Performance of SSVEP-Based BCIs
    Wei, Qingguo
    Zhang, Yixin
    Wang, Yijun
    Gao, Xiaorong
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 2809 - 2821
  • [23] Direct information transfer rate optimisation for SSVEP-based BCI
    Ingel, Anti
    Kuzovkin, Ilya
    Vicente, Raul
    JOURNAL OF NEURAL ENGINEERING, 2019, 16 (01)
  • [24] Stimulus-Stimulus Transfer Based on Time-Frequency-Joint Representation in SSVEP-Based BCIs
    Wang, Ze
    Wong, Chi Man
    Rosa, Agostinho
    Qian, Tao
    Jung, Tzyy-Ping
    Wan, Feng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (02) : 603 - 615
  • [25] Cross-Subject Assistance: Inter- and Intra-Subject Maximal Correlation for Enhancing the Performance of SSVEP-Based BCIs
    Wang, Haoran
    Sun, Yaoru
    Wang, Fang
    Cao, Lei
    Zhou, Wei
    Wang, Zijian
    Chen, Shiyi
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 517 - 526
  • [26] Applying Modular Continuous Restricted Boltzmann Machine to SSVEP-based BCIs
    Chen, Yeou-Jiunn
    Yeng, Chia-Hong
    Chen, Shih-Chung
    Wu, Chung-Min
    PROCEEDINGS OF 4TH IEEE INTERNATIONAL CONFERENCE ON APPLIED SYSTEM INNOVATION 2018 ( IEEE ICASI 2018 ), 2018, : 1182 - 1183
  • [27] Autonomous Parameter Adjustment for SSVEP-Based BCIs with a Novel BCI Wizard
    Gembler, Felix
    Stawicki, Piotr
    Volosyak, Ivan
    FRONTIERS IN NEUROSCIENCE, 2015, 9
  • [28] Accounting for Phase Drifts in SSVEP-Based BCIs by Means of Biphasic Stimulation
    Wu, Hung-Yi
    Lee, Po-Lei
    Chang, Hsiang-Chih
    Hsieh, Jen-Chuen
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (05) : 1394 - 1402
  • [29] Designing a Sum of Squared Correlations Framework for Enhancing SSVEP-Based BCIs
    Kumar, G. R. Kiran
    Reddy, M. Ramasubba
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2019, 27 (10) : 2044 - 2050
  • [30] Spatial Filtering in SSVEP-Based BCIs: Unified Framework and New Improvements
    Wong, Chi Man
    Wang, Boyu
    Wang, Ze
    Lao, Ka Fai
    Rosa, Agostinho
    Wan, Feng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (11) : 3057 - 3072