Measurement of thermophysical properties of human dentin: Effect of open porosity

被引:33
|
作者
de Magalhaes, Manoelita Figueiredo [1 ]
Neto Ferreira, Ricardo Alberto [2 ]
Grossi, Pablo Andrade [2 ]
de Andrade, Roberto Marcio [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Engn Mecan, BR-31270901 Belo Horizonte, MG, Brazil
[2] CDTN, CNEN, BR-30123970 Belo Horizonte, MG, Brazil
关键词
human dentin; thermal diffusivity; flash laser method; density; open porosity; xylol penetration and immersion; method; specific heat; thermal conductivity;
D O I
10.1016/j.jdent.2008.04.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In dentistry caries removal can be performed with rotatory instruments or high intensity laser. Both techniques can heat the tooth and harm the pulp. The literature review about the measurement of human dentin thermophysical properties revealed a great variation of the values obtained by several authors, and most of the studies are outdated. Most of these studies have not directly measured the thermal diffusivity of human dentin, and the reported values are calculated values based on measurements of conductivity, density and specific heat. Objective: The aim of the present study was to measure human dentin thermal diffusivity, density, open porosity and specific heat, and then to calculate its thermal conductivity and analyze the influence of open porosity in these properties. Method: The methods used were: flash laser method for measuring thermal diffusivity, method of penetration and immersion with xylol for density and open porosity and differential scanning calorimetry for measuring specific heat. Calculated results of the thermal conductivity are shown as well. Result: Results of diffusivity, density, open porosity, specific heat and thermal conductivity of measurements performed on five samples are presented and compared with results of other authors. The open porosity of the samples varied between 1.11% and 3.08% of the sample volume, corresponding to densities ranging between 2090 and 2400 kg m(-3), thermal diffusivity: 0.199 and 0.265 x 10(-6) m(2) s(-1), specific heat: 872.5 and 1181.0 J kg(-1) K-1, thermal conductivity: 0.363 and 0.666 W m(-1) K-1. Conclusion: It has been found that there exist a strong correlation between the open porosity of human dentin and its thermal conductivity and density. Both human dentin thermal conductivity and density decrease with the increasing of open porosity, with a confidence of at least 98% and 96.6%, respectively. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:588 / 594
页数:7
相关论文
共 50 条
  • [41] Transient methods for the measurement of thermophysical properties:: Theory and application
    Kubicár, L
    Bohác, V
    Vretenár, V
    TEMPMEKO 2001: 8TH INTERNATIONAL SYMPOSIUM ON TEMPERATURE AND THERMAL MEASUREMENT IN INDUSTRY AND SCIENCE, VOL 1 & 2, PROCEEDINGS, 2002, : 295 - 300
  • [42] Stress relaxation properties of human dentin
    Trengrove, HG
    Carter, GM
    Hood, JAA
    DENTAL MATERIALS, 1995, 11 (5-6) : 305 - 310
  • [43] MECHANICAL PROPERTIES OF HUMAN DENTIN IN SHEAR
    RENSON, CE
    BRADEN, M
    JOURNAL OF DENTAL RESEARCH, 1969, 48 (6P1S) : 1123 - &
  • [44] Measurement and estimation of thermophysical properties of nickel based superalloys
    Quested, P. N.
    Brooks, R. F.
    Chapman, L.
    Morrell, R.
    Youssef, Y.
    Mills, K. C.
    MATERIALS SCIENCE AND TECHNOLOGY, 2009, 25 (02) : 154 - 162
  • [45] Measurement of thermophysical properties by a pulse-heating technique
    Xiao, Peng
    Dai, Jingmin
    Wang, Qingwei
    CHINESE OPTICS LETTERS, 2007, 5 (11) : 642 - 644
  • [46] Simultaneous measurement of thermophysical and mechanical properties of thin films
    Hostetler, J.L.
    Smith, A.N.
    Norris, P.M.
    International Journal of Thermophysics, 1998, 19 (2 SPEC.ISS.) : 569 - 577
  • [47] Simultaneous Measurement of Thermophysical and Mechanical Properties of Thin Films
    J. L. Hostetler
    A. N. Smith
    P. M. Morris
    International Journal of Thermophysics, 1998, 19 : 569 - 577
  • [48] Goniochromatic Properties of Human Tooth Dentin
    Lee, Yong-Keun
    Zhao, Guang-Feng
    Yu, Bin
    Lim, Ho-Nam
    Lu, Huan
    COLOR RESEARCH AND APPLICATION, 2012, 37 (03): : 206 - 211
  • [49] FRACTURE PROPERTIES OF HUMAN ENAMEL AND DENTIN
    RASMUSSEN, ST
    PATCHIN, RE
    SCOTT, DB
    HEUER, AH
    JOURNAL OF DENTAL RESEARCH, 1976, 55 (01) : 154 - 164
  • [50] TENSILE PROPERTIES OF HUMAN ENAMEL AND DENTIN
    HANNAH, CMD
    JOURNAL OF DENTAL RESEARCH, 1971, 50 (03) : 690 - &