The Impact of PbF2-Based Glasses on Radiation Shielding and Mechanical Concepts: An Extensive Theoretical and Monte Carlo Simulation Study

被引:9
|
作者
El-Denglawey, A. [1 ]
Issa, Shams A. M. [2 ,3 ]
Saddeek, Yasser B. [2 ,4 ]
Tekin, H. O. [5 ,6 ]
Zakaly, Hesham M. H. [2 ,7 ]
机构
[1] Taif Univ, Coll Univ Coll Turabah, Dept Phys, POB 11099, At Taif 21944, Saudi Arabia
[2] Al Azhar Univ, Fac Sci, Phys Dept, Assiut 71524, Egypt
[3] Univ Tabuk, Fac Sci, Phys Dept, Tabuk 71451, Saudi Arabia
[4] Majmaah Univ, Dept Phys, Coll Sci Zulf, Al Majmaah 11952, Saudi Arabia
[5] Univ Sharjah, Med Diagnost Imaging Dept, Coll Hlth Sci, Sharjah 27272, U Arab Emirates
[6] Uskudar Univ, Med Radiat Res Ctr USMERA, TR-34672 Istanbul, Turkey
[7] Ural Fed Univ, Inst Phys & Technol, Ekaterinburg 620002, Russia
关键词
Lead-fluoride; Mechanical competence; Monte Carlo FLUKA; Gamma shielding; PHYSICAL-PROPERTIES; OXIDE GLASSES; CONCRETE; SPECTROSCOPY; COEFFICIENTS; PARAMETERS; DYNAMICS; HEMATITE; FLUORIDE; MICRO;
D O I
10.1007/s10904-021-02088-w
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
This work aimed to investigate the impact of Lead-fluoride based glasses via theoretical and simulation techniques on mechanical and radiation shielding parameters. Accordingly, Bi2O3 was blended with TeO2-B2O3-PbF2 glasses by using melt-quenching method. Using Fluka Monte Carlo code, the radiation shielding properties have measured. Moreover, Comparatively higher density PbF80 = 6.163 g/cm(3) with 80 mol % Bi2O3, greater mu, mu(m) and Zeff and lower T-1/2, lambda, tenth value layer values achieved for TeO2-B2O3- PbF2/Bi2O3 glass pointed it out as the best shield of gamma. Besides, the computed effective removal cross-sections against fast neutrons (sigma(R)) observed that the PbF80 sample has commensurately greater with a value 5.2954 (cm(-1)). The results observed that the variation PbF2/Bi2O3 improves the gamma protection ability of Lead-fluoride based glasses. The incremental of Bi2O3 at the expense of PbF2 increases the density and the packing density of the glasses and hence increase the longitudinal modulus-L, shear modulus-S, bulk modulus-K, and Young's modulus-Y from 15.89 to 25.9 GPa, from 8.49 to 12.09 -GPa, from 4.58 to 9.77 GPa, and from 15.74 to 25.69 GPa, respectively. The increase of the elastic moduli can be attrinuted to the glass former role of Bi2O3. The results indicate that the highest PbF2/Bi2O3 ratio encoded PbF00 has the best shielding and mechanical competence with measurable physical properties.
引用
收藏
页码:3934 / 3942
页数:9
相关论文
共 50 条
  • [31] Repercussions of yttrium oxides on radiation shielding capacity of sodium-silicate glass system: experimental and Monte Carlo simulation study
    Tashlykov, O. L.
    Vlasova, S. G.
    Kovyazina, I. S.
    Mahmoud, K. A.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2021, 136 (04):
  • [32] Radiation shielding and mechanical properties of Al2O3-Na2O-B2O3-Bi2O3 glasses using MCNPX Monte Carlo code
    Issa, Shams A. M.
    Tekin, H. O.
    Elsaman, Reda
    Kilicoglu, Ozge
    Saddeek, Yasser B.
    Sayyed, M. I.
    MATERIALS CHEMISTRY AND PHYSICS, 2019, 223 : 209 - 219
  • [33] Impact of TiO2 on physical, optical, and radiation shielding properties of tungsten-based glasses
    Es-soufi, Hicham
    Bih, Hssain
    Sayyed, M. I.
    Bih, Lahcen
    OPTIK, 2023, 272
  • [34] Effect of TiO2/V2O5 substitution on the optical and radiation shielding properties of alkali borate glasses: A Monte Carlo investigation
    Kebaili, Imen
    Boukhris, Imed
    Sayyed, M. I.
    Tonguc, Baris
    Al-Buriahi, M. S.
    CERAMICS INTERNATIONAL, 2020, 46 (16) : 25671 - 25677
  • [35] Investigations of radiation shielding using Monte Carlo method and elastic properties of PbO-SiO2-B2O3-Na2O glasses
    Issa, Shams A. M.
    Saddeek, Yasser B.
    Tekin, H. O.
    Sayyed, M. I.
    Shaaban, Khamies Saber
    CURRENT APPLIED PHYSICS, 2018, 18 (06) : 717 - 727
  • [36] Impact of patient and staff shielding on staff's radiation dose for frequently used isotopes in nuclear medicine: A GEANT4 Monte Carlo simulation
    Qutbi, M.
    Rafiepour, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S789 - S790
  • [37] Clinical implementation of electron Monte Carlo simulation based treatment planning: Study of the impact on a radiobiological basis
    Petillion, S.
    Erven, K.
    Swinnen, A.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S222 - S222
  • [38] Theoretical studies on the chemical decomposition of 5-aza-2′-deoxycytidine: DFT study and Monte Carlo simulation
    Gao, Jie Ying
    Yang, Xin
    Kim, Chan Kyung
    Xue, Ying
    THEORETICAL CHEMISTRY ACCOUNTS, 2012, 131 (02)
  • [39] Optimization progress of large-scale radiation shielding Monte Carlo simulation software based on AIS variance reduction technique system: MCShield
    Wu, Jiajun
    Wu, Zhen
    Hu, Ankang
    Hao, Yisheng
    Pu, Yanheng
    Zhang, Hui
    Qiu, Rui
    Li, Junli
    EPJ NUCLEAR SCIENCES & TECHNOLOGIES, 2025, 11
  • [40] Theoretical studies on the chemical decomposition of 5-aza-2′-deoxycytidine: DFT study and Monte Carlo simulation
    Jie Ying Gao
    Xin Yang
    Chan Kyung Kim
    Ying Xue
    Theoretical Chemistry Accounts, 2012, 131