A new design of a re-entrant cavity ionisation chamber for use in brachytherapy

被引:0
|
作者
Balagi, V. [1 ]
Singh, J. P. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Elect, Bombay 400085, Maharashtra, India
关键词
ion chambers; re-entrant cavity; brachytherapy;
D O I
10.1016/j.nima.2007.06.006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A theoretical model has been developed for evaluating the response of re-entrant cavity ion chambers to various gamma energies from simple geometry considerations. The method involves evaluating the charge generated in a differential volume of the chamber and integrating this over the entire volume of the detector. The theory has been applied to two chambers (one having SS cavity wall and the other having Al cavity wall) developed earlier. The calculated and experimental sensitivities of the SS cavity chamber are 12.78 and 12.41 +/- 0.76 pA/MBq for Co-60. For the Al cavity chamber the sensitivity values for 125 1 are, respectively, 0.047 and 0.049 +/- 0.003 pA/MBq. The technique described above has been used to design and develop re-entrant cavity ionisation chambers for the assay of brachytherapy sources. The design provides adequate sensitivity to assay 37MBq of Ir-192 and good saturation at 150 V for 37 GBq of Co-60. The design ensures that the change in the chamber current remains within +/- 2.5% over a 120mm long 'sweet spot'. Since the outer housing of the chambers carries high voltage a special alumina-titania coating by plasma arc spray has been given to prevent electrical shock hazard to users. Two detectors have been developed: one with SS construction is filled with argon while the other one with aluminium construction is filled open to atmosphere. The two detectors have calculated sensitivity of 3.22 and 1.46 pA/MBq for Co-60 The corresponding experimental sensitivities are 3.3 +/- 0.2 and 1.42 +/- 0.085 pA/MBq, respectively. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:523 / 527
页数:5
相关论文
共 50 条
  • [21] Experimental tests on re-entrant klystron cavity for a gravitational wave antenna
    Barroso, JJ
    Castro, PJ
    Aguiar, OD
    Carneiro, LA
    CLASSICAL AND QUANTUM GRAVITY, 2004, 21 (05) : S1221 - S1224
  • [22] Circuital analysis of a coaxial re-entrant cavity for performing dielectric measurement
    Penaranda-Foix, Felipe L.
    Catala-Civera, Jose M.
    Canos-Marin, Antoni J.
    Garcia-Banos, Beatriz
    2009 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM, VOLS 1-3, 2009, : 1309 - 1312
  • [23] Correlation of the drifts of the salamanca re-entrant, New York
    MacClintock, P
    Apfel, ET
    BULLETIN OF THE GEOLOGICAL SOCIETY OF AMERICA, 1944, 55 (10): : 1143 - 1164
  • [24] NEW METHOD FOR RE-ENTRANT CANNULATION OF DUODENUM IN SHEEP
    IVAN, M
    CANADIAN JOURNAL OF ANIMAL SCIENCE, 1977, 57 (01) : 225 - 227
  • [25] New heuristic for scheduling re-entrant production lines
    Yalaoui, Naim
    Camara, Mema
    Amodeo, Lionel
    Yalaoui, Farouk
    Mahdi, Halim
    CIE: 2009 INTERNATIONAL CONFERENCE ON COMPUTERS AND INDUSTRIAL ENGINEERING, VOLS 1-3, 2009, : 199 - +
  • [27] METHOD TO ASSESS AND AVOID RE-ENTRANT TACHYCARDIAS WITH DUAL CHAMBER SENSING PACEMAKERS
    HAYES, D
    FURMAN, S
    CIRCULATION, 1982, 66 (04) : 218 - 218
  • [28] Experimental and CFD analysis of Re-entrant Combustion Chamber on Diesel Enriched with Hydrogen
    Jyothi U.S.
    Vijaya Kumar Reddy K.
    Journal of The Institution of Engineers (India): Series C, 2021, 102 (01) : 121 - 129
  • [29] SOME CONSIDERATIONS ON THE DESIGN OF THE RE-ENTRANT TUBE VAPOUR TRAP
    STOPS, DW
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1952, 29 (04): : 121 - 125
  • [30] Cavity length and re-entrant jet in 2-D sheet cavitation
    Castellani, I.
    Advances in Fluid Mechanics VI, 2006, 52 : 341 - 350