Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion

被引:1
|
作者
Kuznetsova, S. [1 ]
Sinha, R. [2 ]
Thind, K. [1 ]
Ploquin, N. [1 ]
机构
[1] Univ Calgary, Dept Phys & Astron, Calgary, AB, Canada
[2] Univ Calgary, Dept Oncol, Calgary, AB, Canada
来源
关键词
interfractional motion; liver; Primovist MRI; stereotactic body radiation therapy (SBRT); treatment delivery accuracy; DOSE ACCUMULATION; RADIOTHERAPY; REGISTRATION; CANCER; INJURY; SBRT;
D O I
10.1002/acm2.13333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study used the visualization of hypo-intense regions on liver-specific MRI to directly quantify stereotactic body radiation therapy (SBRT) spatial delivery accuracy. Additionally, the interfractional motion of the liver region was determined and compared with the MRI-based evaluation of liver SBRT spatial treatment delivery accuracy. Primovist-enhanced MRI scans were acquired from 17 patients, 8-12 weeks following the completion of liver SBRT treatment. Direct visualization of radiation-induced focal liver reaction in the form of hypo-intensity was determined. The auto-delineation approach was used to localize these regions, and center-of-mass (COM) discrepancy was quantified between the MRI hypo-intensity and the CT-based treatment plan. To assess the interfractional motion of the liver region, a planning CT was registered to a Cone Beam CT obtained before each treatment fraction. The interfractional motion assessed from this approach was then compared against the localized hypo-intense MRI regions. The mean +/- SD COM discrepancy was 1.4 +/- 1.3 mm in the left-right direction, 2.6 +/- 1.8 mm in an anteroposterior direction, and 1.9 +/- 2.6 mm in the craniocaudal direction. A high correlation was observed between interfractional motion of visualized hypo-intensity and interfractional motion of planning treatment volume (PTV); the quantified Pearson correlation coefficient was 0.96. The lack of correlation was observed between Primovist(R) MRI-based spatial accuracy and interfractional motion of the liver, where Pearson correlation coefficients ranged from -0.01 to -0.26. The highest random and systematic errors quantified from interfractional motion were in the craniocaudal direction. This work demonstrates a novel framework for the direct evaluation of liver SBRT spatial delivery accuracy.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 50 条
  • [31] Patient-specific motion and treatment margins in pancreatic stereotactic body radiation therapy
    Miften, M.
    Jones, B. L.
    Fukami, N.
    Schefter, T.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S198 - S199
  • [32] Skin Toxicity in Stereotactic Body Radiation Therapy - Improving the Treatment Planning and Delivery Process
    Fontenla, S.
    Yorke, E.
    Lovelock, D.
    Mechalakos, J.
    Hunt, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3382 - +
  • [33] Liver motion during cone beam computed tomography guided stereotactic body radiation therapy
    Park, Justin C.
    Park, Sung Ho
    Kim, Jong Hoon
    Yoon, Sang Min
    Song, Si Yeol
    Liu, Zhaowei
    Song, Bongyong
    Kauweloa, Kevin
    Webster, Matthew J.
    Sandhu, Ajay
    Mell, Loren K.
    Jiang, Steve B.
    Mundt, Arno J.
    Song, William Y.
    MEDICAL PHYSICS, 2012, 39 (10) : 6431 - 6442
  • [34] Estimating dose delivery accuracy in stereotactic body radiation therapy: A review of in-vivo measurement methods
    Esposito, Marco
    Villaggi, Elena
    Bresciani, Sara
    Cilla, Savino
    Falco, Maria Daniela
    Garibaldi, Cristina
    Russo, Serenella
    Talamonti, Cinzia
    Stasi, Michele
    Mancosu, Pietro
    RADIOTHERAPY AND ONCOLOGY, 2020, 149 : 158 - 167
  • [35] Four-dimensional planning for motion synchronized dose delivery in lung stereotactic body radiation therapy
    Tachibana, Hidenobu
    Sawant, Amit
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (03) : 467 - 472
  • [36] Dosimetric and Motion Analysis of Margin-Intensive Radiation Delivery by Stereotactic Body Radiation Therapy for Operable Pancreatic Cancer
    Bland, R. E.
    Heinzerling, J. H.
    Mansour, J. C.
    Schwarz, R. E.
    Ramirez, E.
    Ding, C.
    Abdulrahman, R. E.
    Timmerman, R. D.
    Meyer, J. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S339 - S339
  • [37] Stereotactic body radiation therapy and radiofrequency ablation for the treatment of liver metastases: How and when?
    Cacciola, Alberto
    Parisi, Silvana
    Tamburella, Consuelo
    Lillo, Sara
    Ferini, Gianluca
    Molino, Laura
    Iati, Giuseppe
    Pontoriero, Antonio
    Bottari, Antonio
    Mazziotti, Silvio
    Cicero, Giuseppe
    Minutoli, Fabio
    Blandino, Alfredo
    Pergolizzi, Stefano
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (03) : 299 - 306
  • [38] Evaluation of Rotational Errors in Treatment Setup of Stereotactic Body Radiation Therapy of Liver Cancer
    Cao, Minsong
    Lasley, Foster D.
    Das, Indra J.
    DesRosiers, Colleen M.
    Slessinger, Eric D.
    Cardenes, Higinia R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : E435 - E440
  • [39] Stereotactic Body Radiation Therapy: An Ablative Treatment Option for Primary and Secondary Liver Tumors
    Martin Fuss
    Charles R. Thomas
    Annals of Surgical Oncology, 2004, 11 : 130 - 138
  • [40] Stereotactic body radiation therapy: An ablative treatment option for primary and secondary liver tumors
    Fuss, M
    Thomas, CR
    ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (02) : 130 - 138