Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion

被引:1
|
作者
Kuznetsova, S. [1 ]
Sinha, R. [2 ]
Thind, K. [1 ]
Ploquin, N. [1 ]
机构
[1] Univ Calgary, Dept Phys & Astron, Calgary, AB, Canada
[2] Univ Calgary, Dept Oncol, Calgary, AB, Canada
来源
关键词
interfractional motion; liver; Primovist MRI; stereotactic body radiation therapy (SBRT); treatment delivery accuracy; DOSE ACCUMULATION; RADIOTHERAPY; REGISTRATION; CANCER; INJURY; SBRT;
D O I
10.1002/acm2.13333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study used the visualization of hypo-intense regions on liver-specific MRI to directly quantify stereotactic body radiation therapy (SBRT) spatial delivery accuracy. Additionally, the interfractional motion of the liver region was determined and compared with the MRI-based evaluation of liver SBRT spatial treatment delivery accuracy. Primovist-enhanced MRI scans were acquired from 17 patients, 8-12 weeks following the completion of liver SBRT treatment. Direct visualization of radiation-induced focal liver reaction in the form of hypo-intensity was determined. The auto-delineation approach was used to localize these regions, and center-of-mass (COM) discrepancy was quantified between the MRI hypo-intensity and the CT-based treatment plan. To assess the interfractional motion of the liver region, a planning CT was registered to a Cone Beam CT obtained before each treatment fraction. The interfractional motion assessed from this approach was then compared against the localized hypo-intense MRI regions. The mean +/- SD COM discrepancy was 1.4 +/- 1.3 mm in the left-right direction, 2.6 +/- 1.8 mm in an anteroposterior direction, and 1.9 +/- 2.6 mm in the craniocaudal direction. A high correlation was observed between interfractional motion of visualized hypo-intensity and interfractional motion of planning treatment volume (PTV); the quantified Pearson correlation coefficient was 0.96. The lack of correlation was observed between Primovist(R) MRI-based spatial accuracy and interfractional motion of the liver, where Pearson correlation coefficients ranged from -0.01 to -0.26. The highest random and systematic errors quantified from interfractional motion were in the craniocaudal direction. This work demonstrates a novel framework for the direct evaluation of liver SBRT spatial delivery accuracy.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 50 条
  • [1] Interfractional Motion Is Not a Predictor of Delivery Accuracy in Liver Stereotactic Body Radiation Therapy
    Kuznetsova, S.
    Sinha, R.
    Ploquin, N.
    Thind, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E428 - E429
  • [2] Retrospective study on image guided patient positioning to compensate for interfractional motion in stereotactic body radiation therapy of liver malignancies
    Gerum, S.
    Heinz, C.
    Ganswindt, U.
    Roeder, F.
    Corradini, S.
    Freislederer, P.
    Belka, C.
    Niyazi, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 95 - 95
  • [3] Impact of Interfractional Tumor Motion On Respiratory Gated Stereotactic Body Radiation Therapy for Lung Tumors
    Wu, J.
    Betzing, C.
    He, T.
    Fuss, M.
    MEDICAL PHYSICS, 2012, 39 (06) : 3909 - 3909
  • [4] The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer
    Wu, Q. Jackie
    Thongphiew, Danthai
    Wang, Zhiheng
    Chankong, Vira
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2008, 35 (04) : 1440 - 1451
  • [5] Stereotactic body radiation therapy (SBRT) for prostate cancer: Improving treatment delivery efficiency and accuracy
    Mastella, Edoardo
    Epile, Joel E.
    De Guglielmo, Eleonora
    Fabbri, Sara
    Calderoni, Francesca
    Manco, Luigi
    Szilagyi, Klarisa E.
    Malorgio, Antonio
    Turra, Alessandro
    Stefanelli, Antonio
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2024, 30
  • [6] Magnitude and robustness of motion mitigation in stereotactic body radiation therapy of the liver
    Gerum, S.
    Heinz, C.
    Kamp, F.
    Reiner, M.
    Roeder, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S34 - S35
  • [7] Magnitude and robustness of motion mitigation in stereotactic body radiation therapy of the liver
    Heinz, C.
    Gerum, S.
    Kamp, F.
    Reiner, M.
    Roeder, F.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S472 - S473
  • [8] The Dosimetric Impact of Interfractional Organ-at-Risk Movement During Liver Stereotactic Body Radiation Therapy
    Schmid, Ryan K.
    Tai, An
    Klawikowski, Slade
    Straza, Michael
    Ramahi, Khalid
    Li, X. Allen
    Robbins, Jared R.
    PRACTICAL RADIATION ONCOLOGY, 2019, 9 (06) : E549 - E558
  • [9] A Dosimetric Investigation of Interfractional Organ-at-Risk Movements during Stereotactic Body Radiation Therapy for Liver Malignancies
    Schmid, R.
    Tai, A.
    Ramahi, K.
    Klawikowski, S.
    Li, A.
    Robbins, J. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E719 - E720
  • [10] An Evaluation of Treatment Time and Intrafraction Motion in Stereotactic Body Radiation Therapy
    Rough, Leila
    Burbery, Julie
    Hargrave, Catriona
    Brown, Elizabeth
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025,