Time-resolved fluorescence immunoassay (TRFIA) for the simultaneous detection of hs-CRP and lipoprotein(a) in serum

被引:7
|
作者
Ma, Hongyan [1 ]
Mao, Qian [1 ]
Zhu, Yanbin [1 ]
Cong, Chunli [1 ]
Zheng, Shiyu [1 ]
Zhang, Qi [1 ]
Chen, Cuicui [2 ]
Li, Laiqing [2 ]
机构
[1] Beihua Univ, Dept Cardiol, Affiliated Hosp, Jilin, Jilin, Peoples R China
[2] Guangzhou Youdi Biotechnol Co Ltd, 3 Juquan Rd, Guangzhou 510663, Peoples R China
关键词
atherosclerosis; biomarker; high-sensitivity C-reactive protein; lipoprotein(a); serum; time-resolved fluorescence immunoassay; C-REACTIVE PROTEIN; ATHEROSCLEROSIS; MARKERS; INFLAMMATION;
D O I
10.1002/bab.2310
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Elevated serum high-sensitivity C-reactive protein (hs-CRP) and lipoprotein(a) (Lp(a)) levels are associated with the development of native coronary atherosclerosis. We aimed to establish a new method for the simultaneous detection of hs-CRP and Lp(a) to predict the development of atherosclerosis. A one- step time-resolved fluorescence immunoassay (TRFIA) with europium(III) (Eu3+) or samarium(III) (Sm3+) labelswas established, and the performance of this TRFIA (in terms of sensitivity, specificity, accuracy, and cutoff values) was evaluated using clinical serum samples and comparedwith those of registered kits. The sensitivity was 0.052 mu g/ml for hs-CRP and 0.64 mu g/ml for Lp(a). The intra-assay and inter-assay cross-reactivities (CVs) were very low, ranging from 2.05% to 4.67% for hs- CRP and from 2.42% to 6.43% for Lp(a). The CVs were very low (<0.34% and <2.65%, respectively) with five interferents. Additionally, there was a high Pearson coefficient between the present TRFIA method and the registered kits (R-2 = 0.9967 and 0.9906, respectively). These data indicate that this study developed a TRFIA method that can be used for the quantitative detection of hs- CRP and Lp(a) in serum with high sensitivity, specificity, and accuracy. This TRFIA provides a new method for predicting the development of atherosclerosis.
引用
收藏
页码:2617 / 2623
页数:7
相关论文
共 50 条
  • [31] Matrix interference in serum total thyroxin (T4) time-resolved fluorescence immunoassay (TRFIA) and its elimination with the use of streptavidin-biotin separation technique
    Wu, FB
    He, YF
    Han, SQ
    CLINICA CHIMICA ACTA, 2001, 308 (1-2) : 117 - 126
  • [32] Development of a multipurpose time-resolved fluorescence immunoassay for rat insulin
    van Genderen, Farah T.
    Gorus, Frans K.
    Vermeulen, Ilse
    Vekens, Evilien M. F.
    De Pauw, Pieter E. M.
    Pipeleers, Daniel G.
    Van Schravendijk, Chris
    ANALYTICAL BIOCHEMISTRY, 2010, 404 (01) : 8 - 13
  • [33] Total error profiling of a proinsulin time-resolved fluorescence immunoassay
    De Pauw, P. E.
    Mackin, R. B.
    Goubert, R.
    Van Schravendijk, C.
    Gorus, F. K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2403 - 2406
  • [34] ENZYMATICALLY AMPLIFIED TIME-RESOLVED FLUORESCENCE IMMUNOASSAY WITH TERBIUM CHELATES
    CHRISTOPOULOS, TK
    DIAMANDIS, EP
    ANALYTICAL CHEMISTRY, 1992, 64 (04) : 342 - 346
  • [35] TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY FOR THE QUANTIFICATION OF LIPOPROTEIN(A) IN SERUM
    MISSLER, U
    WALEK, T
    STANGE, E
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1995, 33 (11): : 805 - 812
  • [36] Quantification of apolipoprotein D by an immunoassay with time-resolved fluorescence spectroscopy
    Knipping, G
    GoggFassolter, G
    Frohnwieser, B
    Krempler, F
    Kostner, GM
    Malle, E
    JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 202 (01) : 85 - 95
  • [37] Spectra-resolved technique of a sensitive time-resolved fluorescence immunoassay instrument
    Guo, ZY
    Tian, Z
    Jia, YL
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 222 - 226
  • [38] Evaluation of the time resolved fluorescence immunoassay (TRFIA) for the detection of varicella zoster virus (VZV) antibodies following vaccination of healthcare workers
    McDonald, S. L. R.
    Maple, P. A. C.
    Andrews, N.
    Brown, K. E.
    Ayres, K. L.
    Scott, F. T.
    Al Bassam, M.
    Gershon, A. A.
    Steinberg, S. P.
    Breuer, J.
    JOURNAL OF VIROLOGICAL METHODS, 2011, 172 (1-2) : 60 - 65
  • [39] A DUAL-LABEL TIME-RESOLVED FLUORESCENCE IMMUNOASSAY FOR THE SIMULTANEOUS DETERMINATION OF β-HUMAN CHORIONIC GONADOTROPIN AND PROGESTERONE
    Sun, Wenqiao
    Ren, Shoulei
    Yuan, Guangwen
    Wang, Yan
    Li, Laiqing
    Zhang, Licheng
    ANALYTICAL LETTERS, 2014, 47 (18) : 2900 - 2908
  • [40] A dual-label time-resolved fluorescence immunoassay for the simultaneous determination of ferritin and β2-microglobulin
    Liu, Zhi
    Huang, Jing
    Ou, Rui-ming
    Yao, Meng-dong
    She, Yan-lin
    Chen, Rui
    Li, Cheng
    Xu, Li
    Abudureyimu, Aikebaier
    Zhang, Qing
    Liu, Shuang
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (06)