The effect of bladder contrast on dose calculation in volumetric modulated arc therapy planning in patients treated for postoperative prostate cancer

被引:5
|
作者
Ercan, Tulay [1 ]
Igdem, Sefik [1 ]
Alco, Gul [1 ]
机构
[1] Florence Nightingale Gayrettepe Hosp, Dept Radiat Oncol, Cemil Aslan Guder Sok 8,Floor 1, TR-34349 Istanbul, Turkey
关键词
VMAT; Contrast agent; AAA algorithm; Dose calculation; Treatment planning; RADIATION-THERAPY; RADIOTHERAPY; IMRT;
D O I
10.1007/s11604-016-0523-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the effect of contrast agent on dose calculation in volumetric modulated arc therapy (VMAT) in the post-prostatectomy setting. Ten patients were studied. Each patient received planning computed tomography (CT) images with contrast agent. All of the plans were done on virtually simulated contrast-free CT scans. The plan approved by the radiation oncologist was replicated to the contrast CT series. In both of the plans the same monitor unit was used. The doses calculated from the two plans were compared in regard to target volumes and organs at risk. A paired sample t-test was used to evaluate the differences in cumulative dose volume histogram between the two plans. We showed that the use of contrast agent may cause significant differences in dose distribution. There was a significant decrease in doses received by planning target volume (PTV70), rectum V65 Gy, rectum V40 Gy, bladder V65 Gy, penile bulb V40 Gy in plans with contrast-enhanced CT sets. The decrease in mean, maximum and minimum doses received by PTV70 also contributed to the significant decrease in conformity index. Using a contrast agent at the time of CT simulation may cause significant differences in dose distribution. For this reason, the plan should always be carried out on non-contrast CT data sets to avoid additional errors in the treatment planning process.
引用
收藏
页码:376 / 382
页数:7
相关论文
共 50 条
  • [31] Dose-Volume Histogram Parameters and Quality of Life in Patients with Prostate Cancer Treated with Surgery and High-Dose Volumetric-Intensity-Modulated Arc Therapy to the Prostate Bed
    Hanke, Luca
    Tang, Hongjian
    Schroeder, Christina
    Windisch, Paul
    Kudura, Ken
    Shelan, Mohamed
    Buchali, Andre
    Bodis, Stephan
    Foerster, Robert
    Zwahlen, Daniel R.
    CANCERS, 2023, 15 (13)
  • [32] Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer
    Martin, Jeffrey M.
    Handorf, Elizabeth A.
    Price, Robert A.
    Cherian, George
    Buyyounouski, Mark K.
    Chen, David Y.
    Kutikov, Alexander
    Johnson, Matthew E.
    Ma, Chung-Ming Charlie
    Horwitz, Eric M.
    MEDICAL DOSIMETRY, 2015, 40 (03) : 186 - 189
  • [33] Effect of CT Contrast on Volumetric Arc Therapy Planning for Head-and-Neck Cancer
    Liu, A.
    Vora, N.
    Steve, S.
    Liu, A. J.
    Schultheiss, T.
    Wong, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S479 - S479
  • [34] Dose planning of a total body irradiation with Volumetric Modulated Arc Therapy (VMAT)
    Springer, A.
    Winkler, E.
    Putz, E.
    Altenburger, A.
    Gruber, R.
    Moser, K.
    Track, C.
    Hammer, J.
    Geinitz, H.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S182 - S182
  • [35] Optimizing planning CT using past CT images for prostate cancer volumetric modulated arc therapy
    Tanabe, Yoshinori
    Ishida, Takayuki
    Eto, Hidetoshi
    Sera, Tatsuhiro
    Emoto, Yuki
    MEDICAL DOSIMETRY, 2020, 45 (03) : 213 - 218
  • [36] Comparison between two treatment planning systems for volumetric modulated arc therapy optimization for prostate cancer
    Lafond, Caroline
    Gassa, Frederic
    Odin, Christophe
    Drean, Gael
    Even, Justine
    De Crevoisier, Renaud
    Pommier, Pascal
    Manens, Jean-Pierre
    Biston, Marie-Claude
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 2 - 9
  • [37] Reirradiation of Locally Recurrent Prostate Cancer With Volumetric Modulated Arc Therapy
    D'Agostino, Giuseppe Roberto
    Di Brina, Lucia
    Mancosu, Pietro
    Franzese, Ciro
    Iftode, Cristina
    Franceschini, Davide
    Clerici, Elena
    Tozzi, Angelo
    Navarria, Pierina
    Scorsetti, Marta
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 104 (03): : 614 - 621
  • [38] TECHNICAL AND CLINICAL BENCHMARKING OF VOLUMETRIC MODULATED ARC THERAPY FOR PROSTATE CANCER
    Ruchaud, R.
    Faure, G.
    de Crevoisier, R.
    Rodrigues, C.
    Georges, L.
    Bravetti, J.
    Barthelme, E.
    Fau, P.
    Methlin, A.
    Nabet, M.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S566 - S567
  • [39] The effect of endorectal balloon on anorectal dose during postoperative volumetric arc radiotherapy of prostate cancer
    Streller, Tino
    Rusch, Urs
    Lablanca, Maria D. Herraiz
    Minneken, Ira
    Najafi, Yousef
    Shrestha, Binaya
    Oertel, Susanne
    Riesterer, Oliver
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 (03) : 454 - 458
  • [40] VOLUMETRIC MODULATED ARC THERAPY(VMAT) FOR THE TREATMENT OF LOCALIZED PROSTATE CANCER
    Shiraishi, Kenshiro
    Yamamoto, Kentaro
    Haga, Akihiro
    Sakumi, Akira
    Nomoto, Akihiro
    Nakagawa, Keiichi
    ANNALS OF ONCOLOGY, 2014, 25