A bio-inspired coding (BIC) strategy for cochlear implants

被引:14
|
作者
Tabibi, Sonia [1 ,2 ,3 ]
Kegel, Andrea [2 ,3 ]
Lai, Wai Kong [4 ]
Dillier, Norbert [2 ,3 ]
机构
[1] Swiss Fed Inst Technol, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[2] Univ Hosp, ENT Dept, Lab Expt Audiol, Zurich, Switzerland
[3] Univ Zurich, Zurich, Switzerland
[4] RIDBC, Sydney Cochlear Implant Ctr, Sydney, NSW, Australia
关键词
Bio-inspired coding strategy; Electrically evoked compound action potential; Melodic contour identification; Sentence recognition in noise; Cochlear implant; NEURAL RESPONSE TELEMETRY; STIMULATED AUDITORY-NERVE; CHANNEL INTERACTION; PITCH PERCEPTION; SPATIAL SPREAD; EXCITATION; RECOVERY; HEARING; MODEL; REFRACTORINESS;
D O I
10.1016/j.heares.2020.107885
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
A bio-inspired coding (BIC) strategy was implemented in this study with the goal of better representation of spectral and temporal information. The auditory nerve fibers' (ANFs) characteristics such as refractory recovery, facilitation and spatial spread were obtained from ECAP data recorded in 11 CI recipients. These characteristics, together with a non-individualized model-derived adaptation effect, were integrated into the BIC strategy for a better selection of channels. Two variations of the BIC strategy were compared to the conventional advanced combination encoder (ACE) coding strategy: the BIC-I strategy based on the individual CI recipients' ECAP parameters, and the BIC-G strategy based on the median values of ECAP parameters from all CI recipients who participated in the study. The melodic contour identification (MCI) and Oldenburg sentence recognition in noise (OLSA) tests were used to assess and compare the three coding strategies. A significantly better performance in the transformed MCI test results with the rationalized arcsine transformation, was observed for both BIC strategy variations compared to the ACE strategy. There was no significant difference between the two variations of the BIC strategy and the ACE strategy in the OLSA test. No correlation was found between recovery time constants, absolute refractory periods, left and right width of SOE functions from three test electrodes and CI recipients' performances in the two experiments. However, significant correlations were found between facilitation time constant and amplitude and the results of the MCI and OLSA tests for the two variations of the BIC strategy. (C) 2020 The Authors. Published by Elsevier B.V.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Bio-inspired Bio-inspired computer vision based on neural networks
    Antón-Rodríguez M.
    González-Ortega D.
    Díaz-Pernas F.J.
    Martínez-Zarzuela M.
    de la Torre-Díez I.
    Boto-Giralda D.
    Díez-Higuera J.F.
    Pattern Recognition and Image Analysis, 2011, 21 (2) : 108 - 112
  • [22] A bio-inspired condylar knee joint for leg amputees and for knee implants
    Etoundi, A. C.
    Vaidyanathan, R.
    Burgess, S. C.
    DESIGN AND NATURE VI: COMPARING DESIGN IN NATURE WITH SCIENCE AND ENGINEERING, 2012, 160 : 23 - 34
  • [23] Bio-inspired microrobots
    Qiu, Famin
    Zhang, Li
    Tottori, Soichiro
    Marquardt, Klaus
    Krawczyk, Krzysztof
    Franco-Obregon, Alfredo
    Nelson, Bradley J.
    MATERIALS TODAY, 2012, 15 (10) : 463 - 463
  • [24] Bio-inspired optics
    Scribner, DA
    Buckley, LJ
    Satyshur, M
    Sands, R
    Zuccarello, G
    INFRARED TECHNOLOLGY AND APPLICATIONS XXIX, 2003, 5074 : 312 - 317
  • [25] Bio-inspired adhesion
    Ghatak, Animangsu
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2014, 28 (3-4) : 225 - 225
  • [26] Bio-Inspired Networking
    Dressler, Falko
    Suda, Tatsuya
    Carreras, Iacopo
    Murata, Masayuki
    Crowcroft, Jon
    Karlsson, Gunnar
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2010, 28 (04) : 521 - 523
  • [27] A Psychoacoustic "NofM"-Type Speech Coding Strategy for Cochlear Implants
    Waldo Nogueira
    Andreas Büchner
    Thomas Lenarz
    Bernd Edler
    EURASIP Journal on Advances in Signal Processing, 2005
  • [28] Cochlear implants : Influence of the coding strategy on syllable recognition in noise
    Cucis, P.A.
    Berger-Vachon, C.
    Truy, E.
    Thai Van, H.
    Millioz, F.
    Gallego, S.
    Modelling, Measurement and Control C, 2016, 77 (02): : 84 - 97
  • [29] Bio-inspired electrodes
    Dey, Abhishek
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [30] A new sound coding strategy for suppressing noise in cochlear implants
    Hu, Yi
    Loizou, Philipos C.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 124 (01): : 498 - 509