Calibration of radiation protection area monitoring instruments in Sudan

被引:3
|
作者
Suliman, I. I. [1 ]
Youssif, B. E. [1 ]
Beineen, A. A. [1 ]
Hassan, M. [1 ]
机构
[1] Sudan Atom Energy Commiss, Radiat Safety Inst, Khartoum, Sudan
关键词
Calibrations; Radiation dosimetry; Ambient dose equivalent;
D O I
10.1016/j.radmeas.2010.06.005
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This article presents results of measurements for the calibration of radiation protection area monitoring instruments carried out during the period 2006-2008 at Secondary Standard Dosimetry Laboratory of Sudan. The work performed included quality assurance measurements, measurements for the dosimeter calibrations and uncertainty analysis. Calibrations were performed using (137)Cs gamma ray sources produced by OB 85 and OB 34/1 gamma calibrators producing air kerma rate that ranged from 10 mu Gy/h to 50 mGy/h. Area monitoring instruments were calibrated in terms of ambient dose equivalent, H*(10) derived using air kerma to ambient dose equivalent conversion coefficients. Results are presented for 78 area monitoring instruments representing most commonly used types in Sudan. Radioactive check source measurements for the reference chamber showed deviation within 1% limit. The accuracy in the beam output measurements was within 5% internationally considered as acceptable. The results highlighted the importance of radiation protection calibrations. Regulations are further need to ensure safety aspect really meet the required international standards. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1578 / 1581
页数:4
相关论文
共 50 条
  • [41] Wide Area Monitoring, Protection and Control
    Begovic, Miroslav M.
    Messina, Arturo R.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (10) : 1083 - 1085
  • [42] Calibration and testing of a TLD dosemeter for area monitoring
    Buchillier, T
    Aroua, A
    Bochud, F
    Schuler, C
    Stritt, N
    Valley, JF
    Wernli, C
    [J]. RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 705 - 710
  • [43] RADIATION MONITORING - METHODS AND INSTRUMENTS .1. MONITORING TASKS AND PROBLEMS
    BULLEN, MA
    GARRETT, JA
    [J]. BIOMEDICAL ENGINEERING, 1973, 8 (05) : 198 - 201
  • [44] NEUTRON DOSIMETRY FOR RADIATION PROTECTION MONITORING
    ALBERTS, WG
    PIESCH, E
    [J]. ATOMWIRTSCHAFT-ATOMTECHNIK, 1991, 36 (07): : 325 - 328
  • [45] Instruments and system for CLOUDS - A Cloud and Radiation monitoring satellite
    Bizzarri, B
    Spera, P
    Maggi, E
    Coppo, P
    Bonsignori, R
    Zimmermann, P
    Rose, T
    Grant, N
    Vial, L
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES IV, 2000, 4169 : 279 - 290
  • [46] Characterization of dose rate instruments for environmental radiation monitoring
    Wissmann, F.
    Rupp, A.
    Stoehlker, U.
    [J]. KERNTECHNIK, 2007, 72 (04) : 193 - 198
  • [47] THE CALIBRATION OF NEUTRON MONITORS FOR RADIATION PROTECTION PURPOSES AT THE CSIR
    WEIDEMA, O
    [J]. HEALTH PHYSICS, 1986, 50 (02): : 316 - 316
  • [48] CONTRIBUTION TO CALIBRATION OF NEUTRON DOSIMETERS USED IN RADIATION PROTECTION
    HRABOVCOVA, A
    NIKODEMOVA, D
    KUBU, M
    [J]. KERNENERGIE, 1985, 28 (09): : 384 - 387
  • [49] CALIBRATION OF RADIATION INSTRUMENTS FOR MEASUREMENT OF RADIANT-FLUX OF AN ARBITRARY SOURCE
    CROMMELYNCK, D
    [J]. APPLIED OPTICS, 1977, 16 (02): : 302 - 305
  • [50] Developing Vicarious Calibration for Microwave Sounding Instruments Using Lunar Radiation
    Yang, Hu
    Zhou, Jun
    Weng, Fuzhong
    Sun, Ninghai
    Anderson, Kent
    Liu, Quanhua
    Kim, Edward J.
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2018, 56 (11): : 6723 - 6733