摘要
A simulation approach was proposed to analyze the spectra of Doppler signals from stenoed artery in a steady flow, which can provide a useful guidance for detecting the formation understanding, diagnosis and treatment of many cardiovascular diseases. Firstly, by solving Navier-Stokes equations, the velocity distributions in the vessels with various stenoed degrees are calculated. Secondly, power spectral density (PSD) of the Doppler signals is estimated according to the relationship of velocity profiles and power spectral density. Finally, Doppler signals are generated using cosine-superposed methods. The results show that the spectra of Doppler signals are similar to those found in practice. Therefore, the proposed approach is useful for simulating the spectra of Doppler ultrasound signals from stenoed artery in a steady flow.
引用
收藏
页码:275 / +
页数:2
相关论文
共 50 条
  • [41] Doppler ultrasound signal spectral response in the measurement of the blood flow turbulence caused by stenosis
    Solano, J.
    Vazquez, M.
    Rubio, E.
    Sanchez, I.
    Fuentes, M.
    Garcia, F.
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 605 - 613
  • [42] STEADY FLOW THROUGH A STENOSED ARTERY WITH A CLOT
    DEVANATHAN, R
    SAGAYAMARY, RV
    BIOMECHANICS ///, 1989, : 317 - 324
  • [43] Hemodynamic model for analysis of Doppler ultrasound indexes of umbilical blood flow
    Kleiner-Assaf, A
    Jaffa, AJ
    Elad, D
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 276 (06): : H2204 - H2214
  • [44] Time-frequency analysis of the blood flow Doppler ultrasound signal
    Noguchi, Y
    Kashiwagi, E
    Watanabe, K
    Matsumoto, F
    Sugimoto, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (5B): : 3882 - 3887
  • [45] Analysis of Doppler Ultrasound blood flow signal basing on Wavelet Transform
    Li, Jing-hong
    Peng, Hui
    Du, Yu-yuan
    Li, Jing-hua
    Wang, Wen-hui
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2000, 21 (05): : 487 - 489
  • [46] Time-frequency analysis of the blood flow Doppler ultrasound signal
    Noguchi, Yasuaki
    Kashiwagi, Eiichi
    Watanabe, Kohtaro
    Matsumoto, Fujihiko
    Sugimoto, Suguru
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2001, 40 (5 B): : 3882 - 3887
  • [47] ON THE DESIGN AND EVALUATION OF A STEADY FLOW MODEL FOR DOPPLER ULTRASOUND STUDIES
    LAW, YF
    JOHNSTON, KW
    ROUTH, HF
    COBBOLD, RSC
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (05): : 505 - 516
  • [48] QUANTITATIVE STUDY OF STEADY FLOW USING COLOR DOPPLER ULTRASOUND
    TAMURA, T
    COBBOLD, RSC
    JOHNSTON, KW
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (06): : 595 - 605
  • [49] Ultrasound Doppler measurements of low velocity blood flow: Limitations due to clutter signals from vibrating muscles
    Heimdal, A
    Torp, H
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (04) : 873 - 881
  • [50] CONTRIBUTION TO STUDY OF BLOOD-FLOW BY LOW-FREQUENCY SPECTRAL ANALYSIS OF ULTRASONIC DOPPLER SIGNALS APPLIED TO CONTINUOUS-FLOW MODEL
    VERA, JC
    LEFORT, MF
    LHUILLIER, JP
    STOLTZ, JF
    BIORHEOLOGY, 1978, 15 (3-4) : 181 - 191