Thin CaSO4:Dy thermoluminescent dosimeters for calibration of 90Sr+90Y applicators

被引:2
|
作者
Antonio, Patricia L. [1 ]
Oliveira, Mercia L. [2 ]
Caldas, Linda V. E. [1 ]
机构
[1] IPEN CNEN SP, BR-05508000 Sao Paulo, Brazil
[2] Comissao Nacl Energia Nucl, Ctr Reg Ciencias Nucl, BR-50740540 Recife, PE, Brazil
基金
巴西圣保罗研究基金会;
关键词
Sr-90+Y-90 clinical applicators; Thermoluminescence dosimetry; CaSO4:Dy; Depth-dose curves; PERFORMANCE; PELLETS;
D O I
10.1016/j.apradiso.2012.01.003
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Clinical applicators are used in brachytherapy to treat superficial lesions of skin and eye. They should be periodically calibrated according to quality control programs and international recommendations. Thin CaSO4:Dy thermoluminescent dosimeters were used to calibrate various applicators with a dermatological applicator as a reference. The obtained absorbed dose rates were compared with those quoted in their calibration certificates. Depth-dose curves were constructed for all the applicators. A mail dosimetry system was developed for calibration of clinical applicators. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:790 / 793
页数:4
相关论文
共 50 条
  • [31] PRECISION THERMOLUMINESCENT DOSIMETRY USING CASO4-DY TEFLON DOSIMETERS
    MATTHEWS, RJ
    STOEBE, TG
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 171 - 172
  • [32] DEVELOPMENT OF THIN CASO4 - DY TEFLON TL DOSIMETERS FOR BETA-DOSIMETRY IN PERSONNEL MONITORING
    LAKSHMANAN, AR
    CHANDRA, B
    PRADHAN, AS
    KHER, RK
    BHATT, RC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (02): : 107 - 110
  • [33] Intensity variation study of the radiation field in a mammographic system using thermoluminescent dosimeters TLD-900 (CaSO4:DY)
    Correa, E. L.
    Silva, J. O.
    Vivolo, V.
    Potiens, M. P. A.
    Daros, K. A. C.
    Medeiros, R. B.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 116 - 118
  • [34] HIGH-DOSE CHARACTERISTICS OF CAF2 AND CASO4 THERMOLUMINESCENT DOSIMETERS
    BURGKHARDT, B
    SINGH, D
    PIESCH, E
    NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (02): : 363 - 368
  • [35] CaSO4:Dy and LiF:Mg,Cu,P thermoluminescent dosimeters for environmental monitoring in ambient areas of a nuclear power plant
    Zeng, XS
    Zeng, JX
    Tan, GX
    Mai, WJ
    HEALTH PHYSICS, 1996, 70 (03): : 367 - 371
  • [36] THERMOLUMINESCENT CASO4 - DY TEFLON PELLETS FOR BETA-RADIATION DETECTION
    CAMPOS, LL
    LIMA, MF
    RADIATION PROTECTION DOSIMETRY, 1987, 18 (02) : 95 - 97
  • [37] SOME THERMOLUMINESCENT PROPERTIES OF A NEW PREPARATION OF CaSO4:Dy PHOSPHOR.
    Furetta, C.
    Tuyn, J.W.N.
    International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1986, 37 (09): : 935 - 939
  • [38] Study of the luminescent behavior of Spectrolite plus Teflon pellets in 90Sr+90Y beams
    Antonio, Patricia L.
    Oliveira, Raquel A. P.
    Khoury, Helen J.
    Caldas, Linda V. E.
    RADIATION MEASUREMENTS, 2016, 90 : 214 - 218
  • [39] EFFECT OF DIFFERENT CLIMATIC CONDITIONS ON THE PERFORMANCE OF CASO4-DY THERMOLUMINESCENT DOSIMETERS
    BORA, JS
    SUNTA, CM
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1981, 32 (08): : 601 - 602
  • [40] CASO4-DY THERMOLUMINESCENT DOSIMETERS - RESPONSE AS A FUNCTION OF STORAGE-CONDITIONS
    BARTOLOTTA, A
    CALENDA, E
    CALICCHIA, A
    FURETTA, C
    RADIATION EFFECTS LETTERS, 1982, 68 (04): : 121 - 124