Acoustic emission technique for detection of corrosion-induced wire fracture

被引:5
|
作者
Youn, SG [1 ]
Cho, SK [1 ]
Kim, EK [1 ]
机构
[1] Seoul Natl Univ Technol, Dept Civil Engn, Seoul, South Korea
来源
关键词
non-destructive technique; acoustic emission; prestressed concrete bridge; wire fracture; chloride ingress;
D O I
10.4028/www.scientific.net/KEM.297-300.2040
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
There is currently a need to evaluate the non-destructive techniques that are used to detect the fracture of stressed steel wires in grouted post-tensioned concrete bridges. Although continuous acoustic emission (AE) monitoring technique has been developed to detect wire breaks in unbonded tendons, it is not established as the on-site monitoring tools for grouted post-tensioned concrete bridges. In this study, AE measurements were conducted to detect corrosion-induced wire fractures inside a grouted post-tensioned beam. The test beam was drilled with 5mm drill bit to expose individual wires and a reservoir filled with corrosive solution of NaCl and NaOH was formed on the side of the beam. During the experiment, the corrosion site was anodically polarized to + 200mV using a potentiostat and it was continuously monitored and the data obtained were processed with an AE monitoring system. The outcome of this research shows that the continuous AE monitoring system successfully identified and located an individual corrosion-induced wire fracture in a fully grouted post-tensioned concrete beam.
引用
收藏
页码:2040 / 2045
页数:6
相关论文
共 50 条
  • [31] Investigation into corrosion-induced bond degradation between concrete and steel rebar with acoustic emission and 3D laser scan techniques
    Tang F.
    Lin Z.
    Qu H.
    Chen G.
    Journal of Infrastructure Preservation and Resilience, 2022, 3 (01):
  • [32] Corrosion-induced deterioration: Repairs and protection
    Etcheverry, Leandro
    Costa, Jorge
    Szoke, Mike
    POWER ENGINEERING, 2007, 111 (11) : 162 - +
  • [33] CORROSION-INDUCED GOLD SIPOS REACTION
    OSENBACH, JW
    MATERIALS LETTERS, 1992, 13 (2-3) : 80 - 83
  • [34] Damage evaluation and corrosion detection in concrete by acoustic emission
    Ohtsu, M.
    Tomoda, Y.
    Suzuki, T.
    FRACTURE MECHANICS OF CONCRETE AND CONCRETE STRUCTURES, VOLS 1-3: VOL 1: NEW TRENDS IN FRACTURE MECHANICS OF CONCRETE; VOL 2: DESIGN, ASSESSMENT AND RETROFITTING OF RC STRUCTURES; VOL 3: HIGH-PERFORMANCE CONCRETE, BRICK-MASONRY AND ENVIRONMENTAL ASPECTS, 2007, 1-3 : 981 - +
  • [35] Detection of corrosion damage on pressure equipment with acoustic emission
    Lackner, G.
    Tscheliesnig, P.
    ACOUSTIC EMISSION TESTING, 2006, 13-14 : 127 - +
  • [36] Confidence of detection of fracture signals using acoustic emission
    Pullin, R.
    Holford, K. M.
    Evans, S. L.
    ADVANCES IN EXPERIMENTAL MECHANICS V, 2007, 7-8 : 147 - +
  • [37] Evaluation of bridge cables Corrosion Using Acoustic Emission Technique
    Li, Dongsheng
    Ou, Jinping
    NONDESTRUCTIVE CHARACTERIZATION FOR COMPOSITE MATERIALS, AEROSPACE ENGINEERING, CIVIL INFRASTRUCTURE, AND HOMELAND SECURITY 2010, 2010, 7649
  • [38] Acoustic emission technique to identify stress corrosion cracking damage
    Soltangharaeia, V.
    Hill, J. W.
    Ai, Li
    Anay, R.
    Greerb, B.
    Bayat, M.
    Ziehlc, P.
    STRUCTURAL ENGINEERING AND MECHANICS, 2020, 75 (06) : 723 - 736
  • [39] Detection and characterization of chloride induced stress corrosion cracking on SS304 under thermal insulation using acoustic emission technique
    Nuthalapati, Suresh
    Kee, K. E.
    Ismail, Mokhtar B. Che
    Karuppanan, Saravanan
    Hossain, T. M.
    ENGINEERING FAILURE ANALYSIS, 2025, 168