Renal cortical volume: High correlation with pre- and post-operative renal function in living kidney donors

被引:23
|
作者
Gardan, Edouard [1 ]
Jacquemont, Lola [2 ,3 ,4 ]
Perret, Christophe [1 ]
Heudes, Pierre-Marie [1 ]
Gourraud, Pierre-Antoine [2 ,3 ,4 ]
Hourmant, Maryvonne [2 ]
Frampas, Eric [1 ]
Limou, Sophie [3 ,4 ,5 ]
机构
[1] CHU, Radiol Dept, Hotel Dieu 1 Pl Alexis Ricordeau, F-44093 Nantes 1, France
[2] CHU, Nephrol Dept, Nantes, France
[3] Univ Nantes, INSERM, CRTI, UMR 1064, Nantes, France
[4] CHU, ITUN, Nantes, France
[5] Ecole Centrale Nantes, Nantes, France
关键词
Living kidney donor; Computed tomography scan; Renal cortical volume; Kidney function; Isotopic measures; Prediction; COMPUTED-TOMOGRAPHY; NUCLEAR-RENOGRAPHY; TRANSPLANTATION; PREDICTION; AGE;
D O I
10.1016/j.ejrad.2017.12.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: CT volumetry has previously been proposed as an alternative to scintigraphy for the evaluation of pre-donation split renal function and the prediction of post-donation renal function in living kidney donors. The aim of our study was to retrospectively assess the relevance of three CT volumetry techniques for estimating pre-donation kidney function and predicting the risk for chronic kidney disease (CKD) at 1-year post-nephrectomy in a French cohort of living donors using isotopic measures of kidney function. Methods: Kidney volume was quantified pre-donation for 105 donors using three methods total parenchymal three-dimensional renal volume (3DRV), total parenchymal renal volume contouring (RVCt), and renal cortical volume (RCoV). Subjects also had a 51Cr-EDTA scintigraphy to measure glomerular filtration rate (mGFR) pre-donation and 1-year after donation. For each volume, we tested for association with mGFR using univariate regression models, and computed receiver operating characteristics analyses to assess their predictive potential of post-donation CKD. Results: Our population was composed of healthy subjects, who were predominantly female (69%) with a median age at donation of 51yo. Median mGFR was 102 mL/min/1.73 m(2) at pre-donation and 66 mL/min/1.73 m(2) 1-year after nephrectomy. The pre-donation median volume of the preserved kidney was 156 cm(3), 163 cm(3) and 99 cm(3) for the 3DRV, RVCt and RCoV methods respectively, with a high correlation observed between each technique (R > 0.84). For all methods, total kidney volume was significantly associated with pre-donation mGFR (P < 0.001). Preserved kidney volume was also strongly correlated with post-donation mGFR (P < 0.0001), with the strongest correlation observed for RCoV (R = 0.60 vs. R = 0.39 and R = 0.51 for 3DRV and RVCt, respectively). Finally, the RCoV method yielded the best predictive value of 1-year post-donation CKD (AUC = 0.80 vs. AUC = 0.76 and 0.70 for RVCt and 3DRV, respectively). Conclusions: In our cohort of healthy donors with measured kidney function, cortical volumetry (RCoV) appears as the best volumetric technique to use as a surrogate to scintigraphy for estimating pre-donation split renal function and predicting post-donation renal outcomes.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [41] PSYCHIATRIC HISTORY, OPIOID USE, PAIN, AND POST-OPERATIVE OUTCOMES IN LIVING KIDNEY DONORS
    Bruschwein, Heather
    Gulin, Shaina
    Loiselle, Marci
    Rose, Terra
    Jacobs, Jaclyn
    Clement, Lacey
    Arora, Harendra
    Nash, Rebekah
    Woodard, Amy
    Kozlowski, Tomasz
    ANNALS OF BEHAVIORAL MEDICINE, 2018, 52 : S333 - S333
  • [42] PRE- AND POST-OPERATIVE NEUROPSYCHOLOGICAL FUNCTION IN EPILEPTIC PATIENTS UNDERGOING PARTIAL INSULECTOMY
    Boucher, O.
    Rouleau, I
    Escudier, F.
    Malenfant, A.
    Denault, C.
    Charbonneau, S.
    Lassonde, M.
    Bouthillier, A.
    Nguyen, D. K.
    EPILEPSIA, 2013, 54 : 217 - 218
  • [43] Multidetector CT in pre- and post-operative evaluation of living-related liver transplantation
    Elrakhawy, Magdy Mohamed
    Eid, Nevertiti Kamal Eldin
    Wahab, Mohamed Abdel
    Mousa, Amani Ezzat
    Helmy, Eman Mohamed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2013, 44 (02): : 147 - 157
  • [44] Renal function outcomes and kidney biopsy features of living kidney donors with hypertension
    Merzkani, Massini A.
    Mullan, Aidan
    Denic, Aleksandar
    D'Costa, Matthew
    Iverson, Ryan
    Kremers, Walter
    Alexander, Mariam P.
    Textor, Stephen C.
    Taler, Sandra J.
    Stegall, Mark D.
    Augustine, Joshua
    Issa, Naim
    Rule, Andrew D.
    CLINICAL TRANSPLANTATION, 2021, 35 (06)
  • [45] Post-Nephrectomy Renal Outcomes in Obese Living Kidney Donors
    Aggarwal, N.
    Porter, A.
    Tang, I.
    Jain, D.
    Akkina, S.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2012, 12 : 331 - 331
  • [46] Three-dimensional photography for calculating pre- and post-operative volume in breast surgery
    Rao, AK
    Karanas, Y
    Galdino, GM
    Girod, SC
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1355 - 1355
  • [47] Volume-constrained Image Registration for Pre- and Post-operative CT Liver Data
    Beuthien, Bjoern
    Papenberg, Nils
    Heldmann, Stefan
    Fischer, Bernd
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [48] Pre- and post-pyeloplasty renal function: Does it improve?
    McAleer, I
    Kaplan, GW
    PEDIATRICS, 1998, 102 (03) : 837 - 837
  • [49] Cellular Senescence in Pre-Transplant Renal Biopsies Predicts Post-Operative Organ Function.
    McGlynn, Liane
    Stevenson, Karen
    Zino, Samer
    Brown, Michaela
    Prina, Alberto
    Kingsmore, David
    Shiels, Paul
    AMERICAN JOURNAL OF TRANSPLANTATION, 2009, 9 : 571 - 571
  • [50] GRADING THE NON-NEOPLASTIC KIDNEY PREDICTS POST-OPERATIVE RENAL FUNCTION IN RADICAL NEPHRECTOMY SPECIMENS
    Pruthi, Deepak
    Lu, Vivian
    Chhibba, Ruchi
    Weins, Evan
    Gibson, Ian
    McGregor, Thomas
    JOURNAL OF UROLOGY, 2017, 197 (04): : E1367 - E1367