Life cycle assessment of selective non-catalytic reduction (SNCR) of nitrous oxides in a full-scale municipal solid waste incinerator

被引:38
|
作者
Moller, Jacob [1 ]
Munk, Bjarne [2 ]
Crillesen, Kim [2 ]
Christensen, Thomas H. [1 ]
机构
[1] Tech Univ Denmark, DTU Environm, DK-2800 Lyngby, Denmark
[2] Vestforbraending 1S, DK-2600 Glostrup, Denmark
关键词
ENVIRONMENTAL ASSESSMENT; TECHNOLOGIES; EASEWASTE; SYSTEMS; IMPACT; LCA;
D O I
10.1016/j.wasman.2010.12.019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Selective non-catalytic reduction (SNCR) of nitrous oxides in a full-scale municipal solid waste incinerator was investigated using LCA. The relationship between NO(x)-cleaning and ammonia dosage was measured at the plant. Un-reacted ammonia - the ammonia slip - leaving the flue-gas cleaning system adsorbed to fly-ash or in the effluent of the acidic scrubber was quantified from the stoichiometric reaction of NO(x) and ammonia assuming no other reaction products was formed. Of the ammonia slip, 37% was associated with the fly-ash and 63% was in the effluent of the acidic scrubber. Based on NO(x)-cleaning efficiency, the fate of the ammonia slip as well as the environmental impact from ammonia production, the potential acidification and nutrient enrichment from NO(x)-cleaning was calculated as a function of ammonia dosage. Since the exact fate of the ammonia slip could not be measured directly, a number of scenarios were set up ranging from ''best case" with no ammonia from the slip ending up in the environment to "worst case" where all the ammonia slip eventually ended up in the environment and contributed to environmental pollution. In the "best case" scenario the highest ammonia dosage was most beneficial demonstrating that the environmental load associated with ammonia production is of minor importance. In contrast, in a "worst case" scenario" NO(x)-cleaning using SNCR is not recommendable at all, since the impacts from the ammonia slip exceed the saved impacts from the NO(x) removal. Increased dosage of ammonia for removal of NO(x) is recommendable as long as less than 10-20% of the ammonia slip to the effluent of the acidic scrubber ends up in the environment and less than 40% of the slip to the fly-ash ends up in the environment. The study suggests that the actual fate of the ammonia slip is crucial, but since the release of the ammonia may take place during transport and at the facilities that treat the wastewater and treat the fly-ash this factor depends strongly on local conditions and may be hard to determine. Thus, LCA-modeling proved useful in assessing the balance between ammonia dosage and NO(x)-removal in flue-gas cleaning from waste incineration. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1184 / 1193
页数:10
相关论文
共 34 条
  • [11] Life Cycle Assessment of Bottom Ash Management from a Municipal Solid Waste Incinerator (MSWI)
    Margallo, Maria
    Aldaco, Ruben
    Irabien, Angel
    16TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION (PRES'13), 2013, 35 : 871 - 876
  • [12] Computational Fluid Dynamics Simulation of Combustion and Selective Non-Catalytic Reduction in a 750 t/d Waste Incinerator
    Cao, Hai
    Jin, Yan
    Song, Xiangnan
    Wang, Ziming
    Liu, Baoxuan
    Wu, Yuxin
    PROCESSES, 2023, 11 (09)
  • [13] Characteristics of polychlorinated dibenzodioxins/dibenzofurans from a full-scale municipal solid waste (MSW) incinerator in China by MSW classification
    Zhao, Fengbin
    Bian, Rongxing
    Zhang, Tingxue
    Fang, Xin
    Chai, Xiaoli
    Xin, Mingxue
    Li, Weihua
    Sun, Yingjie
    Yuan, Liqun
    Chen, Jian
    Lin, Xuan
    Liu, Lili
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 161 : 50 - 57
  • [14] Investigation of selective catalytic reduction for control of nitrogen oxides in full-scale dairy energy production
    Camarillo, Mary Kay
    Stringfellow, William T.
    Hanlon, Jeremy S.
    Watson, Kyle A.
    APPLIED ENERGY, 2013, 106 : 328 - 336
  • [15] Life Cycle Assessment on the Regeneration of Municipal Solid Waste Incinerator Fly Ash as the Feedstock in the Brick Manufacturing
    Gau, Sue-huai
    Sun, Chang-jung
    SELECTED PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON WASTE MANAGEMENT AND TECHNOLOGY(ICWMT 5), 2010, : 649 - 654
  • [16] ENHANCED SELECTIVE NON-CATALYTIC REDUCTION (SNCR) FOR REFINERY APPLICATIONS: PILOT-SCALE TEST DATA WITH A HYDROGEN PROMOTER
    Swanson, Larry
    Zhou, Wei
    Moyeda, David
    Samuelson, Christopher
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 6, PTS A AND B, 2012, : 1397 - 1399
  • [17] Emission levels and phase distributions of PCDD/Fs in a full-scale municipal solid waste incinerator: The impact of wet scrubber system
    Wang, Pengju
    Yan, Feng
    Cai, Jianjun
    Xie, Feng
    Shen, Xuehua
    Wei, Xuankun
    Yang, Guodong
    Zhong, Rigang
    Huang, Junbing
    Li, Zhongzheng
    Zhang, Zuotai
    JOURNAL OF CLEANER PRODUCTION, 2022, 337
  • [18] PCDD/F levels and phase distributions in a full-scale municipal solid waste incinerator with co-incinerating sewage sludge
    Zhong, Rigang
    Wang, Chen
    Zhang, Zuotai
    Liu, Qingcai
    Cai, Zongwei
    WASTE MANAGEMENT, 2020, 106 : 110 - 119
  • [19] Dioxin emission prediction from a full-scale municipal solid waste incinerator: Deep learning model in time-series input
    Wen, Chaojun
    Lin, Xiaoqing
    Ying, Yuxuan
    Ma, Yunfeng
    Yu, Hong
    Li, Xiaodong
    Yan, Jianhua
    WASTE MANAGEMENT, 2023, 170 : 93 - 102
  • [20] Effect of different air pollution control devices on the gas/solid-phase distribution of PCDD/F in a full-scale municipal solid waste incinerator
    Lin, Xiaoqing
    Ma, Yunfeng
    Chen, Zhiliang
    Li, Xiaodong
    Lu, Shengyong
    Yan, Jianhua
    ENVIRONMENTAL POLLUTION, 2020, 265 (265)