Experimental Results from a Laboratory-Scale Molten Salt Thermocline Storage

被引:4
|
作者
Seubert, Bernhard [1 ]
Mueller, Ralf [1 ]
Willert, Daniel [1 ]
Fluri, Thomas [1 ]
机构
[1] Fraunhofer Inst Solar Energy Syst ISE, Heidenhofstr 2, D-79110 Freiburg, Germany
基金
欧盟地平线“2020”;
关键词
D O I
10.1063/1.4984446
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Single-tank storage presents a valid option for cost reduction in thermal energy storage systems. For low-temperature systems with water as storage medium this concept is widely implemented and tested. For high-temperature systems very limited experimental data are publicly available. To improve this situation a molten salt loop for experimental testing of a single-tank storage prototype was designed and built at Fraunhofer ISE. The storage tank has a volume of 0.4 m(3) or a maximum capacity of 72 kWh(th). The maximum charging and discharging power is 60 kW, however, a bypass flow control system enables to operate the system also at a very low power. The prototype was designed to withstand temperatures up to 550 degrees C. A cascaded insulation with embedded heating cables can be used to reduce the effect of heat loss on the storage which is susceptible to edge effects due to its small size. During the first tests the operating temperatures were adapted to the conditions in systems with thermal oil as heat transfer fluid and a smaller temperature difference. A good separation between cold and hot fluid was achieved with temperature gradients of 95 K within 16 cm.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [21] Comparison of thermocline molten salt storage performances to commercial two-tank configuration
    Angelini, G.
    Lucchini, A.
    Manzolini, G.
    PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 : 694 - 704
  • [22] Review of Molten-Salt Thermocline Tank Modeling for Solar Thermal Energy Storage
    Flueckiger, Scott M.
    Yang, Zhen
    Garimella, Suresh V.
    HEAT TRANSFER ENGINEERING, 2013, 34 (10) : 787 - 800
  • [23] Active control of buzz-saw tones: Experimental results from a laboratory-scale, no-flow rig
    Wilkinson, M. J.
    Joseph, R. F.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (05): : 2618 - 2627
  • [24] Development of a molten-salt thermocline thermal storage system for parabolic trough plants
    Pacheco, JE
    Showalter, SK
    Kolb, WJ
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (02): : 153 - 159
  • [25] Thermal performance analysis of a thermocline thermal energy storage system with FLiNaK molten salt
    Liu, C.
    Cheng, M. S.
    Zhao, B. C.
    Dai, Z. M.
    INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION (EEEP2016), 2017, 52
  • [26] Experimental investigation of flow field in a laboratory-scale compressor
    Ma Hongwei
    Wei Wei
    Ottavy, Xavier
    CHINESE JOURNAL OF AERONAUTICS, 2017, 30 (01) : 31 - 46
  • [27] Laboratory-Scale Experimental Setup for Studying Cable Dampers
    Chen, Lin
    Sun, Limin
    JOURNAL OF ENGINEERING MECHANICS, 2015, 141 (05)
  • [28] Experimental methods for laboratory-scale ensilage of lignocellulosic biomass
    Tanjore, Deepti
    Richard, Tom L.
    Marshall, Megan N.
    BIOMASS & BIOENERGY, 2012, 47 : 125 - 133
  • [29] Modelling of sediment dynamics in a laboratory-scale experimental catchment
    Hancock, GR
    Nuake, J
    Fityus, SG
    HYDROLOGICAL PROCESSES, 2006, 20 (01) : 67 - 84
  • [30] Experimental investigation of flow field in a laboratory-scale compressor
    Ma Hongwei
    Wei Wei
    Xavier Ottavy
    Chinese Journal of Aeronautics, 2017, (01) : 31 - 46