Wind-velocity lidar measurements by use of a Mach-Zehnder interferometer, comparison with a Fabry-Perot interferometer

被引:30
|
作者
Bruneau, D [1 ]
Garnier, A
Hertzog, A
Porteneuve, J
机构
[1] Univ Paris 06, Inst Pierre Simon Laplace, Serv Aeron, F-75252 Paris 05, France
[2] Inst Pierre Simon Laplace, Serv Aeron, F-91371 Verrieres Le Buisson, France
[3] Ecole Polytech, Inst Pierre Simon Laplace, Meteorol Dynam Lab, F-91128 Palaiseau, France
关键词
D O I
10.1364/AO.43.000173
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present the first wind-velocity profiles obtained with a direct-detection Doppler lidar that uses a Mach-Zehnder interferometer (MZI) as spectral discriminator. The measurements were performed in the lower stratosphere, between 10 and 40 km in altitude, at the Observatoire de Haute Provence (OHP), France, during nighttime. They are in excellent agreement with those obtained simultaneously and independently with the already validated double Fabry-Perot interferometer (FPI) of the OHP Doppler lidar (mean difference lower than the combined standard deviation). A statistical analysis shows that the random error obtained with this experimental MZI is 1.94 times the Cramer-Rao lower bound and is approximately half of that given by the FPI (both operating in photometric mode). Nevertheless, the present MZI measurements are sensitive to the presence of atmospheric particles and need an additional correction, whereas the OHP FPI is designed to be insensitive to particulate scattering. (C) 2004 Optical Society of America.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 50 条
  • [21] A Mach-Zehnder Fabry-Perot Hybrid Fibre-Optic Interferometer for a Large Measurement Range Based on the Kalman Filter
    Wang, Yixuan
    Yang, Peigang
    Jin, Tao
    OPTICS, 2024, 5 (02): : 277 - 292
  • [22] Simultaneous measurements of particle backscattering and extinction coefficients and wind velocity by lidar with a Mach-Zehnder interferometer: principle of operation and performance assessment
    Bruneau, D
    Pelon, J
    APPLIED OPTICS, 2003, 42 (06) : 1101 - 1114
  • [23] TUNABLE FABRY-PEROT INTERFEROMETER FOR PHOTOELECTRIC MEASUREMENTS
    LISITSYN, VN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (01): : 174 - &
  • [24] APERTURE CORRECTION IN FABRY-PEROT INTERFEROMETER MEASUREMENTS
    BRUCE, CF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (03): : 349 - &
  • [26] Performance comparison of Fabry-Perot and Mach-Zehnder interferometers for Doppler lidar based on double-edge technique
    Tan, Linqiu
    Hou, Honglu
    Zheng, Qianying
    Li, Hai
    Zhou, Yue
    OPTIK, 2019, 181 : 71 - 80
  • [27] Wind velocity retrieval and field widening techniques of fringe-imaging Mach-Zehnder interferometer for Doppler lidar
    Tan Lin-Qiu
    Hua Deng-Xin
    Wang Li
    Gao Fei
    Di Hui-Ge
    ACTA PHYSICA SINICA, 2014, 63 (22)
  • [28] MEASUREMENTS IN PLASMA DIAGNOSTICS USING A MACH-ZEHNDER INTERFEROMETER
    EXNER, VL
    CESKOSLOVENSKY CASOPIS PRO FYSIKU SEKCE A, 1970, 20 (04): : 396 - +
  • [29] Multiplexed Mach-Zehnder interferometer for multiphase current measurements
    Swart, PL
    Spammer, SJ
    Theron, DC
    OPTICAL ENGINEERING, 1997, 36 (06) : 1817 - 1820
  • [30] Highly sensitive gas pressure sensor based on the enhanced Vernier effect through a cascaded Fabry-Perot and Mach-Zehnder interferometer
    Zhu, Xiping
    Jiang, Chao
    Chen, Hailin
    Wang, Yuan
    Sun, Simei
    Zhang, Han
    Wang, Pei
    Huang, Huiling
    OPTICS EXPRESS, 2022, 30 (19): : 34956 - 34972