Size-exclusion chromatographic protein refolding Fundamentals, modeling and operation

被引:18
|
作者
Freydell, Esteban J. [1 ]
van der Wielen, Luuk A. M. [1 ]
Eppink, Michel H. M. [2 ]
Ottens, Marcel [1 ]
机构
[1] Delft Univ Technol, Dept Biotechnol, Delft, Netherlands
[2] MSD, Oss, Netherlands
关键词
Size exclusion chromatography; On column refolding; Modeling; REFRACTIVE-INDEX DETECTORS; LIGHT-SCATTERING; NONLINEAR CHROMATOGRAPHY; DIFFUSION-COEFFICIENTS; LIQUID-CHROMATOGRAPHY; HUMAN PROINSULIN; AGGREGATION; LYSOZYME; MECHANISM; MEDIA;
D O I
10.1016/j.chroma.2010.10.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Size-exclusion chromatography (SEC) has proven its capability to refold a variety of proteins using a range of gel filtration column materials demonstrated in the growing body of experimental evidence However little effort has been allocated to the development of mechanistic models describing size-exclusion chromatographic refolding reactors (SECRR) Mechanistic models are important since they provide a link between process variables like denatured and reduced protein feed concentration (C-f D&R) flow rate column length etc and performance indicators like refolding yield (Y-N) thereby opening the possibility for in silico design of SECRRs A critical step in the formulation of such models is the selection of an adequate reaction mechanism which provides the direct link between the separation and the refolding yield Therefore in this work we present a methodology using a SEC refolding reactor model supported by a library of reaction mechanisms to estimate a suitable reaction scheme using experimental SEC refolding data SEC refolding data is used since it provides information about the mass distribution of monomers and aggregates after refolding information not readily available from batch dilution refolding data alone Additionally this work presents (1) a systematic analysis of the reaction mechanisms considered using characteristic time analysis and Damkohler maps revealing (a) the direct effect of a given reaction mechanism on the shape of the SEC refolding chromatogram (number of peaks and resolution) and (b) the effect that the competition between convection refolding and aggregation is likely to have on the SEC refolding yield (2) a comparison between the SECR reactor and the batch dilution refolding reactor based on mechanistic modeling quantitatively showing the advantages of the former over the latter and (3) the successful application of the modeling based strategy to study the SEC refolding data of an industrially relevant protein In principle the presented modeling strategy can be applied to any protein refolded using any gel filtration material providing the proper mass balances and activity measurements are available (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:7723 / 7737
页数:15
相关论文
共 50 条
  • [31] Chromatography Fundamentals, Part IX: Light Scattering Detectors for Size-Exclusion Chromatography
    Barth, Howard G.
    LC GC NORTH AMERICA, 2020, 38 (10) : 569 - 579
  • [32] Determination of pore size distributions of porous chromatographic adsorbents by inverse size-exclusion chromatography
    Yao, Y
    Lenhoff, AM
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1037 (1-2) : 273 - 282
  • [33] Application of inverse size-exclusion chromatography in evaluating pore size structure of chromatographic media
    Chi, Weiya
    Hou, Henglei
    Kang, Hongyan
    Qi, Li
    Jin, Haibo
    Zhang, Rongyue
    Jingxi Huagong/Fine Chemicals, 2020, 37 (07): : 1320 - 1326
  • [34] QUANTITATION OF NONIDEAL BEHAVIOR IN PROTEIN SIZE-EXCLUSION CHROMATOGRAPHY
    DUBIN, PL
    EDWARDS, SL
    MEHTA, MS
    TOMALIA, D
    JOURNAL OF CHROMATOGRAPHY, 1993, 635 (01): : 51 - 60
  • [35] Urea-Gradient Protein Refolding in Size Exclusion Chromatography
    Wang, Chaozhan
    Cheng, Yan
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2010, 11 (03) : 289 - 292
  • [36] Studies of the hydrodynamic volume changes that occur during refolding of lysozyme using size-exclusion chromatography
    Batas, B
    Jones, HR
    Chaudhuri, JB
    JOURNAL OF CHROMATOGRAPHY A, 1997, 766 (1-2) : 109 - 119
  • [37] Mathematical modeling and scale-up of size-exclusion chromatography
    Li, ZG
    Gu, YS
    Gu, TY
    BIOCHEMICAL ENGINEERING JOURNAL, 1998, 2 (02) : 145 - 155
  • [38] Size-exclusion chromatographic study of the reduction of recombinant hepatitis B surface antigen
    Tleugabulova, D
    JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (02): : 401 - 407
  • [39] SIZE-EXCLUSION CHROMATOGRAPHIC BEHAVIOR OF METAL-COMPLEXES OF BETA-DIKETONES
    SAITO, M
    KURODA, R
    SHIBUKAWA, M
    ANALYTICAL CHEMISTRY, 1983, 55 (07) : 1025 - 1029
  • [40] Light-scattering and size-exclusion chromatographic characterization of hydroxyethyl cellulose acetate
    Wu, Chi, 1779, John Wiley & Sons Inc, New York, NY, United States (58):