Coronal Diffusion-weighted Magnetic Resonance Imaging of the Kidney: Agreement with Axial Diffusion-weighted Magnetic Imaging in Terms of Apparent Diffusion Coefficient Values

被引:6
|
作者
Wang, Hai-Yi [1 ]
Wang, Jia [2 ]
Tang, Ye-Huan [1 ]
Ye, Hui-Yi [1 ]
Ma, Lin [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Radiol, Beijing 100853, Peoples R China
[2] Handan Cent Hosp, Dept Radiol, Handan 056001, Hebei, Peoples R China
关键词
Apparent Diffusion Coefficient; Diffusion-weighted Magnetic Resonance Imaging; Humans; Kidney; Magnetic Resonance Imaging; RENAL LESIONS; PRELIMINARY-EXPERIENCE; MONOEXPONENTIAL MODEL; ADC VALUE; MRI; CARCINOMA; TUMORS; LIVER;
D O I
10.4103/0366-6999.151103
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Coronal diffusion-weighted magnetic resonance imaging (DW-MRI) and apparent diffusion coefficient (ADC) values have gradually become applied (following conventional axial DW-MRI) in the renal analysis. To explore whether data obtained using coronal DW-MRI are comparable with those derived using axial DW-MRI, this preliminary study sought to assess the agreement in renal ADC values between coronal DW-MRI and axial DW-MRI. Methods: Thirty-four healthy volunteers were enrolled in the study; written consents were obtained. All subjects underwent respiratory-triggered axial and coronal DW-MRI using a 1.5-MR system with b values of 0 and 800 s/mm(2). The signal-to-noise ratios (SNRs) of the two DW-MRI sequences were measured and statistically compared using the paired t-test. The extent of agreement of ADC values of the upper pole, mid-pole, and lower pole of the kidney; the mean ADC values of the left kidney and right kidney; and the mean ADC values of the bilateral kidneys were evaluated via calculation of intraclass correlation coefficients (ICCs) or Bland-Altman method between the two DW-MRI sequences. Results: The SNR of coronal DW-MR images was statistically inferior to that of axial DW-MR images (P < 0.001). The ICCs of the ADC values of each region of interest, and the mean ADC values of bilateral kidneys, between the two sequences, were greater than 0.5, and the mean ADCs of the bilateral kidneys demonstrated the highest ICC (0.869; 95% confidence interval: 0.739-0.935). In addition, 94.1% (32/34), 94.1% (32/34), and 97.1% (31/34) of the ADC bias was inside the limits of agreement in terms of the mean ADC values of the left kidneys, right kidneys, and bilateral kidneys when coronal and axial DWI-MRI were compared. Conclusions: ADC values derived using coronal DW-MRI exhibited moderate-to-good agreement to those of axial DW-MRI, rendering the former an additional useful DW-MRI method, and causing the ADC values derived using the two types of DW-MRI to be comparable.
引用
收藏
页码:499 / 503
页数:5
相关论文
共 50 条
  • [41] Diffusion-weighted magnetic resonance imaging in the management of cholesteatoma
    Mudit Jindal
    Jayesh Doshi
    Manoj Srivastav
    David Wilcock
    Richard Irving
    Ranit De
    [J]. European Archives of Oto-Rhino-Laryngology, 2010, 267 : 181 - 185
  • [42] Diffusion-weighted magnetic resonance imaging of pancreas tumours
    Kartalis, Nikolaos
    Lindholm, Terri L.
    Aspelin, Peter
    Permert, Johan
    Albiin, Nils
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (08) : 1981 - 1990
  • [43] Diffusion-weighted magnetic resonance imaging of the temporal bone
    De Foer, B.
    Vercruysse, J-P.
    Spaepen, M.
    Somers, T.
    Pouillon, M.
    Offeciers, E.
    Casselman, J. W.
    [J]. NEURORADIOLOGY, 2010, 52 (09) : 785 - 807
  • [44] DIFFUSION-WEIGHTED MAGNETIC RESONANCE IMAGING IN THE DETECTION OF SACROILIITIS
    Saad, N.
    Bradbury, L.
    McFarlane, J.
    Hollis, K.
    Brown, M.
    Robinson, P.
    [J]. INTERNAL MEDICINE JOURNAL, 2012, 42 : 18 - 18
  • [45] The role of diffusion-weighted imaging and the apparent diffusion coefficient (ADC) values for breast tumors
    Park, Mi Jung
    Cha, Eun Suk
    Kang, Bong Joo
    Ihn, Yon Kwon
    Baik, Jun Hyun
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2007, 8 (05) : 390 - 396
  • [46] Magnetic resonance diffusion-weighted imaging: extraneurological applications
    Colagrande, S
    Carbone, SF
    Carusi, LM
    Cova, M
    Villari, N
    [J]. RADIOLOGIA MEDICA, 2006, 111 (03): : 392 - 419
  • [47] Diffusion-weighted magnetic resonance imaging in brain death
    Phan, TG
    Wijdicks, EFM
    [J]. STROKE, 2000, 31 (06) : 1458 - 1459
  • [48] Extracranial applications of diffusion-weighted magnetic resonance imaging
    Harriet C. Thoeny
    Frederik De Keyzer
    [J]. European Radiology, 2007, 17 : 1385 - 1393
  • [49] Diffusion-weighted magnetic resonance imaging of nasopharyngeal carcinoma
    Lee, FKH
    King, AD
    Yeung, DKW
    Ma, B
    Ahuja, AT
    [J]. BIOMEDICINE & PHARMACOTHERAPY, 2005, 59 : S395 - S395
  • [50] Diffusion-weighted magnetic resonance imaging in the management of cholesteatoma
    Jindal, Mudit
    Doshi, Jayesh
    Srivastav, Manoj
    Wilcock, David
    Irving, Richard
    De, Ranit
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2010, 267 (02) : 181 - 185