Night-time blood pressure and pulse wave velocity in dialysis patients

被引:2
|
作者
Li, Xiurong [1 ]
Jiang, Qingbo [2 ]
Wu, Wenhui [1 ]
Xu, Xianlin [3 ]
Miao, Liying [1 ]
Jin, Lina [1 ]
Xue, Lina [1 ]
Huang, Tian [1 ]
Di, Jia [1 ]
Liu, Jinfeng [1 ,2 ,3 ]
He, Xiaozhou [1 ,3 ]
机构
[1] Soochow Univ, Affiliated Hosp 3, Dept Hemodialysis, Changzhou, Peoples R China
[2] Soochow Univ, Affiliated Hosp 3, Dept Lab, Changzhou, Peoples R China
[3] Soochow Univ, Affiliated Hosp 3, Dept Urol, Changzhou, Peoples R China
关键词
Ambulatory blood pressure; Blood pressure; Hypertension; PWV; Dialysis; STAGE RENAL-DISEASE; HEMODIALYSIS-PATIENTS; AORTIC STIFFNESS; GENERAL-POPULATION; MORTALITY; HYPERTENSION; DETERMINANT; PROGRESSION; PROFILE; INDEX;
D O I
10.1007/s10157-017-1464-z
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Ambulatory blood pressure (ABP) monitoring and carotid-femoral pulse wave velocity (cfPWV) provide important cardiovascular risk information for dialysis patients. This study aims to evaluate the risk factors of cfPWV and the associations between ambulatory blood pressure, especially night-time blood pressure and cfPWV. We conducted a cross-sectional study in patients on maintenance hemodialysis. ABP and cfPWV were measured on a midweek interdialytic day. Associations were determined using Pearson's correlation analysis and multiple stepwise regression model. Systolic BPs and pulse pressures, but not diastolic BPs, were significantly and positively associated with cfPWV. In a stepwise regression model, age, diabetes mellitus and all-period systolic BP were independently associated with cfPWV. When day-time and night-time BPs were included in the analysis, respectively, only night-time systolic BP and age remained as independently associated with cfPWV. Ambulatory BPs are potent associates of cfPWV and night-time systolic BP, rather than day-time BPs, is an independently predictor of cfPWV. Our results support the view that controlling of nocturnal hypertension provides a unique cardiovascular protection effect.
引用
收藏
页码:173 / 178
页数:6
相关论文
共 50 条
  • [21] Night-time blood pressure patterns and target organ damage: A review
    Routledge, Faye S.
    McFetridge-Durdle, Judith A.
    Dean, C. R.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (02) : 132 - 138
  • [22] Nocturia and night-time blood pressure: an association too frequently overlooked
    Muiesan, Maria Lorenza
    Paini, Anna
    [J]. JOURNAL OF HYPERTENSION, 2018, 36 (11) : 2135 - 2137
  • [23] Impact of night-time blood pressure on cerebral white matter hyperintensity in elderly hypertensive patients
    Kokubo, Manabu
    Shimizu, Atsuya
    Mitsui, Toko
    Miyagi, Motohiro
    Nomoto, Kenichiro
    Murohara, Toyoaki
    Toba, Kenji
    Sakurai, Takashi
    [J]. GERIATRICS & GERONTOLOGY INTERNATIONAL, 2015, 15 : 59 - 65
  • [24] Pulse Wave Velocity in Continuous Blood Pressure Measurements
    Meigas, K.
    Lass, J.
    Karai, D.
    Kattai, R.
    Kaik, J.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 626 - +
  • [25] Pulse wave velocity, blood pressure and bicycle tyres
    Bockenhauer, Detlef
    [J]. PEDIATRIC NEPHROLOGY, 2011, 26 (08) : 1343 - 1343
  • [26] Aortic pulse wave velocity and blood pressure classification
    Protogerou, Athanse
    Blacher, Jacques
    Safar, Michel E.
    [J]. JOURNAL OF HYPERTENSION, 2006, 24 : 120 - 121
  • [27] Pulse wave velocity, blood pressure and bicycle tyres
    Detlef Bockenhauer
    [J]. Pediatric Nephrology, 2011, 26 : 1343 - 1343
  • [28] Office and ambulatory blood pressure and pulse wave velocity
    Cameron, James D.
    [J]. JOURNAL OF HYPERTENSION, 2011, 29 (05) : 832 - 833
  • [29] EFFECT OF BLOOD PRESSURE ALTERATION ON PULSE WAVE VELOCITY
    NYE, ER
    [J]. BRITISH HEART JOURNAL, 1964, 26 (02): : 261 - &
  • [30] Association of night-time blood pressure dipping, albuminuria with blood pressure control and variability, glucose control in diabetic hypertensive patients
    Gontmacher, B
    Paran, E
    [J]. HYPERTENSION, 2003, 42 (04) : 645 - 645