Point-of-Care Ultrasound Assessment of the Inferior Vena Cava in Mechanically Ventilated Critically Ill Children

被引:9
|
作者
Basu, Sonali [1 ,3 ]
Sharron, Matthew [1 ,3 ]
Herrera, Nicole [1 ,3 ]
Mize, Marisa [1 ,3 ]
Cohen, Joanna [2 ,3 ]
机构
[1] Childrens Natl Hlth Syst, Div Crit Care Med, 111 Michigan Ave NW, Washington, DC 20010 USA
[2] Childrens Natl Hlth Syst, Div Emergency Med, Washington, DC USA
[3] George Washington Univ, Sch Med & Hlth Sci, Washington, DC 20052 USA
关键词
fluid status; inferior vena cava; point-of-care ultrasound; CENTRAL VENOUS-PRESSURE; RIGHT ATRIAL PRESSURE; FLUID OVERLOAD; SONOGRAPHIC MEASUREMENT; DIAMETER; BALANCE; RESPONSIVENESS; MORTALITY;
D O I
10.1002/jum.15247
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives The objective of this study was to compare the ultrasound-measured inferior vena cava distensibility index (IVCdi), inferior vena cava distensibility variability (IVCdv), and inferior vena cava-to-aorta ratio (IVC/Ao) to other common methods to assess fluid status in mechanically ventilated pediatric critically ill patients. These methods include central venous pressure (CVP), percent fluid overload by weight (%FOw), and percent fluid overload by volume (%FOv). Methods This was a prospective observational study of a convenience sample of 50 mechanically ventilated pediatric patients. Ultrasound measurements of the inferior vena cava and aorta were obtained, and the IVCdi, IVCdv, and IVC/Ao were calculated and compared to CVP, %FOw, and %FOv. Results The median %FOw was 5%, and the median %FOv was 10%. The mean CVP +/- SD was 8.6 +/- 4 mm Hg. The CVP had no significant correlation with %FOw or %FOv. There was no significant correlation of the IVCdi with CVP (r = -0.145; P = .325) or %FOv (r = 0.119; P = .420); however, the IVCdi had a significant correlation with %FOw (P = .012). There was also no significant relationship of the IVCdv with CVP (r = -0.135; P = .36) or %FOv (r = 0.128; P = .385); however, there was a significant correlation between the IVCdv and %FOw (P = .012). There was no relationship between the IVC/Ao and any other measures of fluid status. Conclusions In this cohort of mechanically ventilated pediatric intensive care unit patients, many commonly used markers of fluid status showed weak correlations with each other. The IVCdi and IVCdv significantly correlated with %FOw and may have potential as markers for fluid overload in this patient population.
引用
收藏
页码:1573 / 1579
页数:7
相关论文
共 50 条
  • [31] Ultrasound measured collapsibility of inferior vena cava comparison with central venous pressure in critically ill patients
    Kadhim, Maytham M.
    Ibrahim, Abdul Sattar Hadi
    Saad, Muthana Abdul Kadhim
    MEDICAL SCIENCE, 2021, 25 (113) : 1774 - 1779
  • [32] The role of temporary inferior vena cava filters in critically ill surgical inferior patients
    Offner, PJ
    Hawkes, A
    Madayag, R
    Seale, F
    Maines, C
    ARCHIVES OF SURGERY, 2003, 138 (06) : 591 - 594
  • [33] Inferior Vena Cava Ultrasound in Children: Comparing Two Common Assessment Methods*
    de Souza, Tiago H.
    Giatti, Marina P.
    Nogueira, Roberto J. N.
    Pereira, Ricardo M.
    Soub, Ana C. S.
    Brandao, Marcelo B.
    PEDIATRIC CRITICAL CARE MEDICINE, 2020, 21 (04) : E186 - E191
  • [34] Ultrasound assessment of the inferior vena cava in heart failure
    Macho, Juan Torres
    Falco, Mercedes Duffot
    MEDICINA CLINICA, 2024, 163 (02): : 78 - 80
  • [35] INFERIOR VENA CAVA DIMENSIONS POORLY REFLECT CIRCULATING BLOOD VOLUME IN THE MECHANICALLY VENTILATED
    Taitano, Genia
    Inouye, David
    Takanishi, Danny
    Hayashi, Michael
    Brown, Jason
    Sandokji, Yousif
    Harvey, Scott
    Yu, Mihae
    CRITICAL CARE MEDICINE, 2020, 48
  • [36] Muscle atrophy in mechanically-ventilated critically ill children
    Johnson, Ryan W.
    Ng, Kay W. P.
    Dietz, Alexander R.
    Hartman, Mary E.
    Baty, Jack D.
    Hasan, Nausheen
    Zaidman, Craig M.
    Shoykhet, Michael
    PLOS ONE, 2018, 13 (12):
  • [37] Qualitative assessment of the diaphragm in the mechanically ventilated critically ill, using shear wave ultrasound elastography
    Flatres, Aurelien
    Aarab, Yassir
    Matecki, Stefan
    Molinari, Nicolas
    Gamon, Lucie
    Amalric, Mathieu Mathieu
    Larcher, Romaric
    Jaber, Samir
    Klouche, Kada
    Jung, Boris
    ACTA PHYSIOLOGICA, 2019, 227
  • [38] PROPOFOL AS A BRIDGE TO EXTUBATION FOR MECHANICALLY VENTILATED, CRITICALLY ILL CHILDREN
    Patel, Abhishek
    Bhalala, Utpal
    Thangavelu, Malarvizhi
    Sauter, Morris
    Appachi, Elumalai
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 390 - 390
  • [39] Diaphragmatic atrophy and dysfunction in critically ill mechanically ventilated children
    Mistri, Sabyasachi
    Dhochak, Nitin
    Jana, Manisha
    Jat, Kana R.
    Sankar, Jhuma
    Kabra, Sushil K.
    Lodha, Rakesh
    PEDIATRIC PULMONOLOGY, 2020, 55 (12) : 3457 - 3464
  • [40] Inferior Vena Cava Collapsibility Index and Central Venous Pressure for Fluid Assessment in the Critically Ill Patient
    Dodhy, Afia Arshed
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2021, 31 (11): : 1273 - 1277