The algorithm for processing key comparisons to establish equivalence between national standards

被引:0
|
作者
Kharitonov, IA
机构
关键词
equivalence of national standards; key comparisons; population; reference value;
D O I
10.1023/A:1024829500275
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To establish equivalence between national standards, it is proposed to consider a priori the key comparisons made as regards the selection of data belonging to a single population. It is also proposed to estimate reference values as arithmetic means or medians. All national standards are recognized as equivalent with these values for the uncertainties established from the comparisons.
引用
收藏
页码:406 / 408
页数:3
相关论文
共 50 条
  • [31] Comparisons of working pH standards of national metrological institutes in COOMET
    O. V. Karpov
    V. D. Kutovoy
    V. A. Zvezdina
    I. A. Lukashov
    M. V. Kazakova
    [J]. Measurement Techniques, 2010, 53 : 40 - 50
  • [32] A Simplified Algorithm for Processing the Results of Paired Comparisons
    Sysoev, Yu. S.
    [J]. MEASUREMENT TECHNIQUES, 2018, 61 (07) : 655 - 659
  • [33] Degrees of equivalence for the key comparison BIPM.RI(I)-K3 between national primary standards for medium-energy x-rays
    Burns, D. T.
    [J]. METROLOGIA, 2003, 40
  • [34] Degrees of equivalence for the key comparison BIPM.RI(I)-K2 between national primary standards for low-energy x-rays
    Burns, D. T.
    [J]. METROLOGIA, 2003, 40
  • [35] On the Wrong Key Randomisation and Key Equivalence Hypotheses in Matsui's Algorithm 2
    Bogdanov, Andrey
    Tischhauser, Elmar
    [J]. FAST SOFTWARE ENCRYPTION (FSE 2013), 2014, 8424 : 19 - 38
  • [36] Inpatient management of psoriasis: a multicentre service review to establish national admission standards
    Woods, A. L.
    Rutter, K. J.
    Gardner, L. S.
    Lewis, V. J.
    Saxena, S.
    George, S. A.
    Chalmers, R. J. G.
    Griffths, C. E. M.
    Speight, E. L.
    Anstey, A. V.
    Ronda, L.
    McGibbon, D.
    Barker, J. W. N.
    Smith, C. H.
    [J]. BRITISH JOURNAL OF DERMATOLOGY, 2008, 158 (02) : 266 - 272
  • [37] TRANSFER LEAK STUDIES AND COMPARISONS OF PRIMARY LEAK STANDARDS AT THE NATIONAL-BUREAU-OF-STANDARDS AND SANDIA-NATIONAL-LABORATORIES
    HYLAND, RW
    EHRLICH, CD
    TILFORD, CR
    THORNBERG, S
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1986, 4 (03): : 334 - 337
  • [40] SOME PROBLEMS CONCERNING THE ESTIMATE OF THE DEGREE OF EQUIVALENCE IN MRA KEY COMPARISONS AND OF ITS UNCERTAINTY
    Pavese, Franco