An experimental comparison of three direct methods of marine source signature estimation

被引:20
|
作者
Laws, R
Landro, M
Amundsen, L
机构
[1] Schlumberger Cambridge Res Ltd, Cambridge CB3 0EL, England
[2] STATOIL, Res, N-7004 Trondheim, Norway
关键词
D O I
10.1046/j.1365-2478.1998.980334.x
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Three methods for estimation of the pressure wavefield generated by a marine airgun array are tested experimentally and compared. In the trial a variety of radiation angles and array configurations were used and some large synchronization errors were deliberately introduced. The source was equipped with near-field hydrophones and a subsource ministreamer. A tethered far-field hydrophone was used so that the three estimated far-field signatures could be compared with an independent measurement. The knowledge of the source signature is important for on-board source array QC, deconvolution, multiple attenuation, stratigraphic trap prediction, modelling and inversion, AVO analysis and reservoir monitoring. The methods perform very well and give estimates whose frequency-domain spectra match the measured spectra to within a few dB and within a few tens of degrees of phase over the tested bandwidth of 3.5-110 Ha. The time-domain error-energy is typically only a few per cent of the signal energy for radiation angles within about 30 degrees of the vertical. The third method proved to be sensitive to an experiment;al shortcoming leading to overloading of the ministreamer and meaningful comparison was not possible for some test configurations.
引用
收藏
页码:353 / 389
页数:37
相关论文
共 50 条
  • [31] ESTIMATION OF FATTY ACIDS IN TISSUES - A COMPARISON OF DIRECT WEIGHT AND VOLUMETRIC METHODS
    RAMAKRISHNAN, S
    BALASUBRAMANIAN, K
    ANALYTICAL BIOCHEMISTRY, 1970, 38 (01) : 304 - +
  • [32] Comparison of weight estimation methods used when direct weighing is not possible
    Black, KJL
    Young, SJ
    Barnett, PLJ
    PEDIATRIC RESEARCH, 2000, 47 (04) : 104A - 104A
  • [33] An experimental comparison of three methods for collision handling in virtual environments
    Jacobson, J
    Lewis, M
    PROCEEDINGS OF THE HUMAN FACTORS AND ERGONOMICS SOCIETY 41ST ANNUAL MEETING, 1997, VOLS 1 AND 2, 1997, : 1273 - 1277
  • [34] How to measure time preferences: An experimental comparison of three methods
    Hardisty, David J.
    Thompson, Katherine F.
    Krantz, David H.
    Weber, Elke U.
    JUDGMENT AND DECISION MAKING, 2013, 8 (03): : 236 - 249
  • [35] Comparison of three controller tuning methods: A simulation and experimental study
    Abbas, A
    Mohammed, EMA
    HUNGARIAN JOURNAL OF INDUSTRIAL CHEMISTRY, 1997, 25 (04): : 309 - 313
  • [36] Guinea pig sensitization assays: An experimental comparison of three methods
    Modjtahedi, Bobeck S.
    Fortenbach, Christopher R.
    Marsano, Joseph G.
    Gandhi, Aaron M.
    Staab, Robert
    Maibach, Howard I.
    CUTANEOUS AND OCULAR TOXICOLOGY, 2011, 30 (02) : 129 - 137
  • [37] Source apportionment of trace metals in river sediments: A comparison of three methods
    Chen, Haiyang
    Teng, Yanguo
    Li, Jiao
    Wu, Jin
    Wang, Jinsheng
    ENVIRONMENTAL POLLUTION, 2016, 211 : 28 - 37
  • [38] Comparison of two methods of estimation of low density lipoprotein cholesterol, the direct versus Friedewald estimation
    Sahu S.
    Chawla R.
    Uppal B.
    Indian Journal of Clinical Biochemistry, 2005, 20 (2) : 54 - 61
  • [39] A comparison of three established age estimation methods on an adult Spanish sample
    Rissech, Carme
    Wilson, Jeremy
    Winburn, Allysha Powanda
    Turbon, Daniel
    Steadman, Dawnie
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2012, 126 (01) : 145 - 155
  • [40] Motor threshold in transcranial magnetic stimulation:: comparison of three estimation methods
    Tranulis, C
    Guéguen, B
    Pham-Scottez, A
    Vacheron, MN
    Cabelguen, G
    Costantini, A
    Valero, G
    Gatinovski, A
    NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2006, 36 (01): : 1 - 7