A new method to obtain transmission images for planar whole-body activity quantification

被引:16
|
作者
Minarik, D [1 ]
Sjögreen, K [1 ]
Ljungberg, M [1 ]
机构
[1] Lund Univ, Dept Med Radiat Phys, SE-22185 Lund, Sweden
关键词
transmission; quantification; scintillation camera; X-ray; CT;
D O I
10.1089/cbr.2005.20.72
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Dosimetry is important in the evaluation of new radiopharmaceuticals and in radionuclide therapy treatment planning. The base is an accurate in vivo measurement of the spatial and temporal distribution of the administered radioactivity. This can be made by planar whole-body activity quantification using the conjugate-view method where a geometrical-mean image is corrected for attenuation by a measured transmission image. We present a new method to measure whole-body transmission images using the X-ray unit on a single photon emission computed tomography/computed tomography (SPECT/CT) scintillation system. Method: Two general problems are associated with this method: (1) the divergence of the X-ray beam ana (2) the scaling of the resulting image. We have applied linear transformations and scale by a system-generated factor to obtain images corresponding to a radiological depth at 70 keV. We validated the method by measurements of the radiological depth for different types of phantoms, and in terms of activity quantification accuracy when applying the method for attenuation correction. Results: An accuracy of within +/- 4% was found for both the radiological depth measurements and for the activity-quantification measurements. Conclusions: The advantage with the proposed method is that it is fast (2 minutes for a 2-minute scan), it has good spatial resolution and signal-to-noise ratio, and it is easy to carry out for the patient.
引用
收藏
页码:72 / 76
页数:5
相关论文
共 50 条
  • [21] Automatic bone segmentation in whole-body CT images
    André Klein
    Jan Warszawski
    Jens Hillengaß
    Klaus H. Maier-Hein
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 21 - 29
  • [22] Activity quantification of planar gamma camera images
    Svegborn, S. Leide
    Sydoff, M.
    Norrgren, K.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S338 - S338
  • [23] COMPARISON OF A NEW WHOLE-BODY SCANNER WITH A LARGE CRYSTAL SCANNING CAMERA IN WHOLE-BODY IMAGING
    ELL, PJ
    MYERS, MJ
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1977, 2 (04): : 281 - 284
  • [24] The transmission of vertical whole-body vibration to the body segments of standing subjects
    Harazin, B
    Grzesik, J
    [J]. JOURNAL OF SOUND AND VIBRATION, 1998, 215 (04) : 775 - 787
  • [25] The transmission of vertical whole-body vibration to the body segments of standing subjects
    Inst. Occup. Med. and Environ. Hlth., 13 Kościelna str, 41-200 Sosnowiec, Poland
    [J]. J Sound Vib, 4 (775-787):
  • [26] MEASURING GAMMA ACTIVITY WITH WHOLE-BODY COUNTERS
    MENEELY, GR
    LINDE, S
    MENEELY, EU
    [J]. NUCLEONICS, 1963, 21 (10): : 46 - &
  • [27] Effect of motion on the ADC quantification accuracy of whole-body DWIBS
    Stone, Alan J.
    Browne, Jacinta E.
    Lennon, Brian
    Meaney, James F.
    Fagan, Andrew J.
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2012, 25 (04) : 263 - 266
  • [28] Effect of motion on the ADC quantification accuracy of whole-body DWIBS
    Alan J. Stone
    Jacinta E. Browne
    Brian Lennon
    James F. Meaney
    Andrew J. Fagan
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2012, 25 : 263 - 266
  • [29] RADIOFLUOROGRAPHY - A METHOD FOR RAPID WHOLE-BODY AUTORADIOGRAPHY
    HANSEN, SE
    [J]. JOURNAL OF HISTOTECHNOLOGY, 1990, 13 (04) : 283 - 287
  • [30] COMPARISON OF WHOLE-BODY FAST SPECT/CT RE-PROJECTED PLANAR AND PLANNER SWEEP BONE IMAGES
    Alqahtani, Mansour
    [J]. INTERNAL MEDICINE JOURNAL, 2023, 53 : 66 - 66