A novel time-of-flight spectrometer for PAES

被引:6
|
作者
Legl, Stefan [1 ]
Hugenschmidt, Christoph [2 ]
机构
[1] Tech Univ Munich, Phys Dept E21, James Franck Str, D-85748 Garching, Germany
[2] Technische Univ Munche, ZWE FRM 2, D-85747 Garching, Germany
关键词
D O I
10.1002/pssc.200675802
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Positron annihilation induced Auger electron spectroscopy (PAES) uses the annihilation of a positron with an electron of the inner shell of atoms whereas X-rays or high-energy electrons initiate the ionisation in conventional AES. Advantages of PAES are the extremely high surface sensitivity and the higher signal to noise ratio. In order to benefit from PAES one has to use a low-energy positron beam of high intensity, which is available at NEPOMUC at the new Munich research reactor FRM-II. The energy of the Auger electrons is mostly analysed by hemispherical energy analysers. Due to their small solid angle (typically >= 0.1%) and the necessity to scan over certain energy ranges in >= 1eV steps one still needs several hours using an intense positron source like NEPOMUC (at the FRM-II) or even weeks at the lab-beam based on a beta-emitter to obtain an Auger spectrum. For this reason, a novel time-of-flight spectrometer (TOF-PAES) was developed, which efficiently collects the Auger electrons emitted in a solid angle of 2 pi around the sample, and hence reduces the measurement time to less than one hour. (C) 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
引用
收藏
页码:3981 / +
页数:2
相关论文
共 50 条
  • [31] TIME-OF-FLIGHT ELECTRON VELOCITY SPECTROMETER
    BALDWIN, GC
    FRIEDMAN, SI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (04): : 519 - &
  • [32] A FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER
    GARG, JB
    NUCLEAR INSTRUMENTS & METHODS, 1959, 6 (01): : 72 - 82
  • [33] THE HARWELL TIME-OF-FLIGHT NEUTRON SPECTROMETER
    MERRISON, AW
    WIBLIN, ER
    NATURE, 1951, 167 (4244) : 346 - 347
  • [34] Advances in biomarker discovery on a novel tandem time-of-flight mass spectrometer
    Gostick, D.
    Willetts, M.
    Williamson, B.
    Parker, K.
    Araki, N.
    MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S319 - S319
  • [35] INTRINSIC TIME RESOLUTION OF DETECTORS IN A TIME-OF-FLIGHT SPECTROMETER
    POUTHAS, J
    AGARWAL, S
    ENGRAND, M
    PISANI, C
    NUCLEAR INSTRUMENTS & METHODS, 1977, 145 (03): : 445 - 451
  • [36] An application of the electron mirror in the time-of-flight spectrometer
    Artamonov, OM
    Samarin, SN
    Smirnov, AO
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2001, 120 (1-3) : 11 - 26
  • [37] A TIME-OF-FLIGHT SPECTROMETER FOR MASS MEASUREMENTS AT LAMPF
    VIEIRA, DJ
    BUTLER, GW
    CLARK, JL
    WOUTERS, JM
    POSKANZER, AM
    REMSBERG, LP
    WOLLNIK, H
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 183 (MAR): : 18 - NUCL
  • [38] TIME-OF-FLIGHT SPECTROMETER FOR SLOW-NEUTRONS
    STOCKMEYER, R
    KERNTECHNIK, 1972, 14 (01) : 13 - +
  • [39] TIME-OF-FLIGHT SPECTROMETER IN EXPERIMENTS WITH DD NEUTRONS
    ANDREEV, EA
    SITKO, SP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1976, 19 (04) : 1004 - 1006
  • [40] A SEGMENTED TIME-OF-FLIGHT MASS-SPECTROMETER
    SRIVASTAVA, SK
    IGA, I
    RAO, MVVS
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (09) : 1379 - 1382