A novel time-of-flight spectrometer for PAES

被引:6
|
作者
Legl, Stefan [1 ]
Hugenschmidt, Christoph [2 ]
机构
[1] Tech Univ Munich, Phys Dept E21, James Franck Str, D-85748 Garching, Germany
[2] Technische Univ Munche, ZWE FRM 2, D-85747 Garching, Germany
关键词
D O I
10.1002/pssc.200675802
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Positron annihilation induced Auger electron spectroscopy (PAES) uses the annihilation of a positron with an electron of the inner shell of atoms whereas X-rays or high-energy electrons initiate the ionisation in conventional AES. Advantages of PAES are the extremely high surface sensitivity and the higher signal to noise ratio. In order to benefit from PAES one has to use a low-energy positron beam of high intensity, which is available at NEPOMUC at the new Munich research reactor FRM-II. The energy of the Auger electrons is mostly analysed by hemispherical energy analysers. Due to their small solid angle (typically >= 0.1%) and the necessity to scan over certain energy ranges in >= 1eV steps one still needs several hours using an intense positron source like NEPOMUC (at the FRM-II) or even weeks at the lab-beam based on a beta-emitter to obtain an Auger spectrum. For this reason, a novel time-of-flight spectrometer (TOF-PAES) was developed, which efficiently collects the Auger electrons emitted in a solid angle of 2 pi around the sample, and hence reduces the measurement time to less than one hour. (C) 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
引用
收藏
页码:3981 / +
页数:2
相关论文
共 50 条
  • [1] Fabrication of a novel micro time-of-flight mass spectrometer
    Yoon, HJ
    Kim, JH
    Choi, ES
    Yang, SS
    Jung, KW
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 97-8 : 441 - 447
  • [2] Pseudorandom time-of-flight analysis with a time-of-flight mass spectrometer
    Bewig, L
    Buck, U
    Gandhi, SR
    Winter, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (02): : 417 - 422
  • [3] A TIME-OF-FLIGHT MASS SPECTROMETER
    WILSON, DB
    VACUUM, 1969, 19 (07) : 323 - &
  • [4] A FAST TIME-OF-FLIGHT SPECTROMETER
    BECKMAN, L
    HANSEN, J
    JANSSON, R
    NUCLEAR INSTRUMENTS & METHODS, 1967, 52 (01): : 157 - &
  • [5] NANOSECOND TIME-OF-FLIGHT SPECTROMETER
    LAPSHIN, VG
    PETRUKHIN, VI
    RYKALIN, VI
    KHAZINS, DM
    TSISEK, Z
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (06): : 1329 - +
  • [6] A TIME-OF-FLIGHT MASS SPECTROMETER
    GOUDSMIT, SA
    PHYSICAL REVIEW, 1948, 74 (05): : 622 - 623
  • [7] A TIME-OF-FLIGHT MASS SPECTROMETER
    KATZENSTEIN, HS
    FRIEDLAND, SS
    PHYSICAL REVIEW, 1954, 93 (02): : 363 - 363
  • [8] A FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER
    MUBARAKMAND, S
    KHAN, NA
    MAHER, PK
    NUCLEAR INSTRUMENTS & METHODS, 1970, 86 (01): : 149 - +
  • [9] FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER
    NEILSON, GC
    DAWSON, WK
    JOHNSON, FA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (11): : 963 - 975
  • [10] TIME-OF-FLIGHT SPECTROMETER FOR ULTRACOLD NEUTRONS
    LYNN, JW
    MILLER, WA
    DOMBECK, TW
    RINGO, GR
    KROHN, VE
    FREEDMAN, MS
    PHYSICA B & C, 1983, 120 (1-3): : 114 - 117