The 10-100 keV beam line of the Sao Paulo Microtron electron accelerator

被引:8
|
作者
Vanin, Vito R. [1 ]
Maidana, Nora L. [1 ]
Mangiarotti, Alessio [1 ]
Lima, Roberto R. [1 ]
Malafronte, Alexandre A. [1 ]
Barros, Suelen F. [1 ]
Martins, Marcos N. [1 ]
机构
[1] Univ Sao Paulo, Inst Fis, Rua Matao 1371,Cidade Univ, BR-05508090 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Electron beam; Inner shell; Bremsstrahlung; Atomic alignment; Electron scattering; K-SHELL IONIZATION; CROSS-SECTION; EFFICIENCY; DETECTORS; ENERGIES; PHOTONS; IMPACT;
D O I
10.1016/j.radphyschem.2018.03.013
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Sao Paulo Microtron 10 - 100 keV electron beam-line described here was designed to allow precise measurements of the electron-atom interaction cross-sections using reproducible arrangements. The irradiation chamber has thirteen spectroscopy windows for x-ray detectors and a multi-target ladder. The photon background on the target was reduced by using a large and deep Faraday cup, lining the chamber's interior with plastic, and mounting the targets in carbon fiber frames. The current research plan includes measurements of: electron doubly differential bremsstrahlung cross sections; inner shell ionization cross sections; angular distributions of L X-rays, and the angular distribution of scattered electrons.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 50 条
  • [21] Energization of the 10-100 KEV electrons in solar flares by strongly-driven reconnection
    Moore, RL
    Larosa, TN
    Miller, JA
    Shore, SN
    MAGNETODYNAMIC PHENOMENA IN THE SOLAR ATMOSPHERE: PROTOTYPES OF STELLAR MAGNETIC ACTIVITY, 1996, : 565 - 566
  • [22] BEAM SPOT MEASUREMENTS ON A 400 KEV ELECTRON-ACCELERATOR
    MILLER, A
    RADIATION PHYSICS AND CHEMISTRY, 1979, 13 (1-2): : 1 - 4
  • [23] Compact beam transport system for a 6 MeV electron beam to a race-track-microtron accelerator
    Verschuur, J.W.J.
    Analbers, R.
    Van Der Slot, P.J.M.
    Ernst, G.J.
    Witteman, W.J.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 427 (1-2): : 68 - 73
  • [24] Compact beam transport system for a 6 MeV electron beam to a race-track-microtron accelerator
    Verschuur, JWJ
    Analbers, R
    van der Slot, PJM
    Ernst, GJ
    Witteman, WJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 427 (1-2): : 68 - 73
  • [25] OPTIMUM COUPLING OF A MICROTRON ACCELERATOR CAVITY IN CASE OF VARIABLE ELECTRON-BEAM LOADING
    HAAG, HW
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (01): : 79 - 81
  • [26] Parameters measurement of 100 keV gyral electron beam
    Zhao, Jun-Ping
    Tian, Jin-Shou
    Bai, Yong-Lin
    Liu, Bai-Yu
    Ouyang, Xian
    Yang, Wen-Zheng
    Bai, Xiao-Hong
    Huang, Lei
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2007, 19 (03): : 487 - 490
  • [27] Advances in simulation capability: A path towards modeling 10-100 GeV plasma accelerator stages
    Mori, WB
    ADVANCED ACCELERATOR CONCEPTS, 2004, 737 : 75 - 85
  • [28] PULVERISATION CATHODIQUE DE CIBLES METALLIQUES PAR DES IONS DENERGIE MOYENNE (10-100 KEV)
    COLOMBIE, N
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES, 1961, 252 (14): : 2108 - &
  • [29] Calculation of CsI photocathode spectral response in 10-100 keV X-ray energy region
    Li Yu-Kun
    Chen Tao
    Li Jin
    Yang Zhi-Wen
    Hu Xin
    Deng Ke-Li
    Cao Zhu-Rong
    ACTA PHYSICA SINICA, 2018, 67 (08)
  • [30] Precise Calibration and Application of Hard X-Ray Detector in Energy Range of 10-100 keV
    He Xiaoan
    Yi Rongqing
    Li Chaoguang
    Chen Bolun
    Li Fan
    Zheng Jianhua
    Xue Yanlin
    Wang Feng
    ACTA OPTICA SINICA, 2022, 42 (11)