Effect of slice thickness and primary 2D versus 3D virtual dissection on colorectal lesion detection at CT Colonography in 452 asymptomatic adults

被引:39
|
作者
Johnson, C. Daniel
Fletcher, Joel G.
MacCarty, Robert L.
Mandrekar, Jay N.
Harmsen, William S.
Limburg, Paul J.
Wilson, Lynn A.
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Biostat, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Gastroenterol, Rochester, MN 55905 USA
关键词
colonoscopy; colorectal cancer; CT colonography; oncologic imaging; virtual dissection display;
D O I
10.2214/AJR.07.2354
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare the performance of primary 3D search using 360 virtual dissection with primary 2D search using a 2.5- versus a 1.25-mm slice thickness. SUBJECTS AND METHODS. Four hundred fifty-two asymptomatic patients underwent CT colonography (CTC) and colonoscopy. Examinations were reconstructed to 1.25- and 2.5- mm slice thicknesses and interpreted using primary 3D search (360 virtual dissection) and primary 2D search. Two of three experienced reviewers were randomly assigned to each case; 1,808 interpretations were performed. RESULTS. There were 64 adenomas >= 6 mm, 26 of which were large adenomas >= 1 cm. For adenomas 6-9 mm in diameter, the area under the receiver operating characteristic curve (AUC) using 2.5-mm data sets was 0.66, 0.62, 0.90 and 0.78, 0.69, 0.67 for reviewers 1, 2, and 3, respectively, using primary 3D versus 2D search (p = not significant [NS]). For neoplasms = 10 mm, the AUC using 2.5- mm data sets was 0.74, 0.85, 0.89 and 0.66, 0.86, 0.92 for reviewers 1, 2, and 3 using primary 3D versus 2D search (p = NS). There was no significant difference using 1.25- mm collimation. Double review using both primary 3D and 2D search yielded sensitivities of 84% (16/19) and 95% (18/19) for large neoplasms (>= 1 cm) using 2.5- and 1.25mm data sets, respectively. Five of five (100%) adenocarcinomas were identified. The sensitivity of colonoscopy for large neoplasms was 77% (20/26) (20% [1/5] for adenocarcinoma). CONCLUSION. No advantage exists for 1.25- or 2.5- mm slice thickness or for primary 3D versus 2D search at CTC. Double review using primary 3D ( virtual dissection) and 2D search reduces interobserver variability and competes with colonoscopy for the detection of large lesions.
引用
收藏
页码:672 / 680
页数:9
相关论文
共 50 条
  • [41] Comparison of image and lesion noise between a 3D LSO PET/CT and a 2D BGO PET system
    Dahlbom, M
    Schiepers, CS
    Ratib, O
    Czernin, J
    Phelps, ME
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 283P - 283P
  • [42] Polyp detection at CT colonography: Inadequate primary 3D endoluminal reference standard precludes meaningful comparison - Response
    Taylor, Stuart A.
    Halligan, Steve
    RADIOLOGY, 2007, 244 (01) : 317 - 317
  • [43] Comparison and ensemble of 2D and 3D approaches for COVID-19 detection in CT images
    Ahmed, Sara Atito Ali
    Yavuz, Mehmet Can
    Sen, Mehmet Umut
    Gulsen, Faith
    Tutar, Onur
    Korkmazer, Bora
    Samanci, Cesur
    Sirolu, Sabri
    Hamid, Rauf
    Eryurekli, Ali Ergun
    Mammadov, Toghrul
    Yanikoglu, Berrin
    NEUROCOMPUTING, 2022, 488 : 457 - 469
  • [44] Correction to: The “true” acetabular anteversion angle (AV angle): 2D CT versus 3D model
    Kira A. Barlow
    Zdzislaw Krol
    Pawel Skadlubowicz
    Chao Dong
    Vanja Zivkovic
    Andreas H. Krieg
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 409 - 412
  • [45] Helical CT scan with 2D and 3D reconstructions and Virtual Endoscopy versus conventional endoscopy in the assessment of airway disease in neonates, infants and children
    Yunus, Mahira
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2012, 62 (11) : 1154 - 1160
  • [46] External radiotherapy of intact breast: A comparison between 2D (single CT- slice) and 3D (full CT-slices) plans
    Falahatpour, Z.
    Aghamiri, S. M. R.
    Anbiaee, R.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2011, 9 (02): : 121 - 125
  • [47] Slice-Consistent 3D Volumetric Brain CT-to-MRI Translation with 2D Brownian Bridge Diffusion Model
    Choo, Kyobin
    Jun, Youngjun
    Yun, Mijin
    Hwang, Seong Jae
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT VII, 2024, 15007 : 657 - 667
  • [48] Classification of EEG evoked in 2D and 3D virtual reality: traditional machine learning versus deep learning
    Zuo, MingLiang
    Yu, BingBing
    Sui, Li
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2025, 11 (01):
  • [49] Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography
    Villablanca, JP
    Jahan, R
    Hooshi, P
    Lim, S
    Duckwiler, G
    Patel, A
    Sayre, J
    Martin, N
    Frazee, J
    Bentson, J
    Vifiuela, F
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (07) : 1187 - 1198
  • [50] Intra- and interobserver variability of thyroid volume measurements in healthy adults by 2D versus 3D ultrasound
    Andermann, P.
    Schloegl, S.
    Maeder, U.
    Luster, M.
    Lassmann, M.
    Reiners, Chr
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2007, 46 (01): : 1 - 7