Pullout characteristics of percutaneous pedicle screws with different cement augmentation methods in elderly spines: An in vitro biomechanical study

被引:25
|
作者
Charles, Y. P. [1 ,2 ]
Pelletier, H. [3 ,4 ]
Hydier, P. [3 ]
Schuller, S. [1 ,2 ]
Garnon, J. [5 ]
Sauleau, E. A. [6 ]
Steib, J. -P. [1 ,2 ]
Clavert, P. [1 ,3 ,7 ]
机构
[1] Univ Strasbourg, Grp Etud Biomecan Osteoarticulaire Strasbourg, Federat Med Translat Strasbourg, GEBOAS, F-67085 Strasbourg, France
[2] Hop Univ Strasbourg, Serv Chirurg Rachis, F-67091 Strasbourg, France
[3] Univ Strasbourg, Inst Natl Sci Appl, F-67000 Strasbourg, France
[4] Univ Strasbourg, UPR CNRS 22, Inst Charles Sadron, F-67000 Strasbourg, France
[5] Hop Univ Strasbourg, Serv Radiol Intervent, F-67091 Strasbourg, France
[6] Hop Univ Strasbourg, Dept Sante Publ, F-67091 Strasbourg, France
[7] Univ Strasbourg, Inst Anat Normale, Fac Med, F-67085 Strasbourg, France
关键词
Pullout test; Percutaneous pedicle screw augmentation; Elderly spine; Cement distribution; Rupture pattern; INITIAL FIXATION; STRENGTH; INSERTION;
D O I
10.1016/j.otsr.2015.01.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Vertebroplasty prefilling or fenestrated pedicle screw augmentation can be used to enhance pullout resistance in elderly patients. It is not clear which method offers the most reliable fixation strength if axial pullout and a bending moment is applied. The purpose of this study is to validate a new in vitro model aimed to reproduce a cut out mechanism of lumbar pedicle screws, to compare fixation strength in elderly spines with different cement augmentation techniques and to analyze factors that might influence the failure pattern. Materials and methods: Six human specimens (82-100 years) were instrumented percutaneously at L2, L3 and L4 by non-augmented screws, vertebroplasty augmentation and fenestrated screws. Cement distribution (2 ml PMMA) was analyzed on CT. Vertebral endplates and the rod were oriented at 45 to the horizontal plane. The vertebral body was held by resin in a cylinder, linked to an unconstrained pivot, on which traction (10 N/s) was applied until rupture. Load-displacement curves were compared to simultaneous video recordings. Results: Median pullout forces were 488.5 N (195-500) for non-augmented screws, 643.5 N (270-1050) for vertebroplasty augmentation and 943.5 N (750-1084) for fenestrated screws. Cement augmentation through fenestrated screws led to significantly higher rupture forces compared to non-augmented screws (P=0.0039). The pullout force after vertebroplasty was variable and linked to cement distribution. A cement bolus around the distal screw tip led to pullout forces similar to non-augmented screws. A proximal cement bolus, as it was observed in fenestrated screws, led to higher pullout resistance. This cement distribution led to vertebral body fractures prior to screw pullout. Conclusion: The experimental setup tended to reproduce a pullout mechanism observed on radiographs, combining axial pullout and a bending moment. Cement augmentation with fenestrated screws increased pullout resistance significantly, whereas the fixation strength with the vertebroplasty prefilling method was linked to the cement distribution. (C) 2015 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:369 / 374
页数:6
相关论文
共 50 条
  • [1] The Biomechanical Properties of Cement-Augmented Pedicle Screws for Osteoporotic Spines
    Wang, Yuetian
    Yang, Lei
    Li, Chunde
    Sun, Haolin
    GLOBAL SPINE JOURNAL, 2022, 12 (02) : 323 - 332
  • [2] Pedicle screw cement augmentation. A mechanical pullout study on different cement augmentation techniques
    Costa, Francesco
    Ortolina, Alessandro
    Galbusera, Fabio
    Cardia, Andrea
    Sala, Giuseppe
    Ronchi, Franco
    Uccelli, Carlo
    Grosso, Rossella
    Fornari, Maurizio
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (02) : 181 - 186
  • [3] Percutaneous Juxtapedicular Cement Salvage of Failed Pedicle Screws: A Cadaveric Biomechanical Study
    Kurland, David B.
    Lendhey, Matin
    Delavari, Nader
    Winfield, Jalen
    Mahoney, Jonathan
    Bucklen, Brandon
    Frempong-Boadu, Anthony
    NEUROSURGERY, 2023, 69 : 110 - 111
  • [4] Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling
    Chen, Lih-Huei
    Tai, Ching-Lung
    Lee, De-Mei
    Lai, Po-Liang
    Lee, Yen-Chen
    Niu, Chi-Chien
    Chen, Wen-Jer
    BMC MUSCULOSKELETAL DISORDERS, 2011, 12
  • [5] Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling
    Lih-Huei Chen
    Ching-Lung Tai
    De-Mei Lee
    Po-Liang Lai
    Yen-Chen Lee
    Chi-Chien Niu
    Wen-Jer Chen
    BMC Musculoskeletal Disorders, 12
  • [6] Biomechanical comparison of pullout strengths of six pedicle screws with different thread designs
    Karakasli, Ahmet
    Acar, Nihat
    Husemoglu, R. Bugra
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (01): : 192 - 197
  • [7] Pullout evaluation of sawbone experiment in different types of pedicle screws combined with bone cement augmentation for severe osteoporotic spine
    Yang, Shih-Chieh
    Liu, Pao-Hsin
    Tu, Yuan-Kun
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2018, 20 (02) : 55 - 64
  • [8] Bone cement or bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation
    S. L. Evans
    C. M. Hunt
    S. Ahuja
    Journal of Materials Science: Materials in Medicine, 2002, 13 : 1143 - 1145
  • [9] Bone cement or bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation
    Evans, SL
    Hunt, CM
    Ahuja, S
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (12) : 1143 - 1145
  • [10] Pullout Strength of Pedicle Screws Inserted Using Three Different Techniques: A Biomechanical Study on Polyurethane Foam Block
    Wu, Lien-Chen
    Hsieh, Yueh-Ying
    Tsuang, Fon-Yih
    Kuo, Yi-Jie
    Chen, Chia-Hsien
    Chiang, Chang-Jung
    BIOENGINEERING-BASEL, 2023, 10 (06):