Preliminary evaluation of a new pediatric air displacement plethysmograph for body composition assessment in infants

被引:44
|
作者
Yao, M
Nommsen-Rivers, L
Dewey, K
Urlando, A
机构
[1] Life Measurement Inc, Concord, CA 94520 USA
[2] Univ Calif Davis, Dept Nutr, Davis, CA 95616 USA
关键词
body composition; infant;
D O I
10.1007/s00592-003-0027-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A preliminary evaluation of a new air displacement plethysmography (ADP) system for body composition assessment in infants was performed on 17 subjects on 2 consecutive days. Mean (+/-SD) percent body fat (%BF) obtained from test I on day 1, and tests I and 2 on day 2 was 23.21 +/- 7.63, 22.94 +/- 7.50, and 22.55 +/- 7.61, respectively. Mean differences in %BF of within- (-0.39 +/- 0.81) and between-day tests (-0.27 +/- 0.97) did not significantly differ from zero. %BF 95% limits of agreements were very close (-2.0-1.2, and -2.2-1.7 for within- and between-day tests, respectively). %BF SDs (0.52 and 0.60 %BF for within- and between-day reliability, respectively) were not a function of the subject's behavioral state, body weight, or %BE Mean %BF obtained from the 3 tests (22.90 +/- 7.56) was comparable with expected %BF values calculated using data from multi-Compartment studies (25.84 +/- 8.39 and 21.93 +/- 4.46).
引用
收藏
页码:S55 / S58
页数:4
相关论文
共 50 条
  • [1] Preliminary evaluation of a new pediatric air displacement plethysmograph for body composition assessment in infants
    M. Yao
    L. Nommsen-Rivers
    K. Dewey
    A. Urlando
    [J]. Acta Diabetologica, 2003, 40 : s55 - s58
  • [2] Validation of a new pediatric air displacement plethysmograph for assessing body composition in infants
    Ma, GS
    Yao, MJ
    Urlando, A
    Wong, W
    Nommsen-Rivers, L
    Dewey, K
    [J]. OBESITY RESEARCH, 2003, 11 : A134 - A134
  • [3] Validation of a new pediatric air-displacement plethysmograph for assessing body composition in infants
    Ma, GS
    Yao, MJ
    Liu, Y
    Lin, AW
    Zou, H
    Urlando, A
    Wong, WW
    Nommsen-Rivers, L
    Dewey, KG
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2004, 79 (04): : 653 - 660
  • [4] A new air displacement plethysmograph for the measurement of body composition in infants
    Urlando, A
    Dempster, P
    Aitkens, S
    [J]. PEDIATRIC RESEARCH, 2003, 53 (03) : 486 - 492
  • [5] A New Air Displacement Plethysmograph for the Measurement of Body Composition in Infants
    Alessandro Urlando
    Philip Dempster
    Susan Aitkens
    [J]. Pediatric Research, 2003, 53 : 486 - 492
  • [6] EVALUATION OF A NEW AIR DISPLACEMENT PLETHYSMOGRAPH FOR MEASURING HUMAN-BODY COMPOSITION
    MCCRORY, M
    GOMEZ, T
    BERNAUER, E
    MOLE, P
    [J]. FASEB JOURNAL, 1995, 9 (04): : A980 - A980
  • [7] EVALUATION OF A NEW AIR DISPLACEMENT PLETHYSMOGRAPH FOR MEASURING HUMAN-BODY COMPOSITION
    MCCRORY, MA
    GOMEZ, TD
    BERNAUER, EM
    MOLE, PA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1995, 27 (12): : 1686 - 1691
  • [8] Evaluation of a new pediatric air-displacement plethysmograph for body-composition assessment by means of chemical analysis of bovine tissue phantoms
    Sainz, RD
    Urlando, A
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2003, 77 (02): : 364 - 370
  • [9] A new air displacement plethysmograph for the determination of Japanese body composition
    Miyatake, N
    Nonaka, K
    Fujii, M
    [J]. DIABETES OBESITY & METABOLISM, 1999, 1 (06): : 347 - 351
  • [10] Evaluation of air-displacement plethysmography for body composition assessment in preterm infants
    Roggero, Paola
    Gianni, Maria L.
    Amato, Orsola
    Piemontese, Pasqua
    Morniroli, Daniela
    Wong, William W.
    Mosca, Fabio
    [J]. PEDIATRIC RESEARCH, 2012, 72 (03) : 316 - 320