Design and Implementation of a blood pressure device with high sampling frequency to analyze cardiovascular diseases in LabVIEW

被引:0
|
作者
Hoseinzadeh, Mohammad Saleh [1 ]
Ekhlasi, Ali [1 ]
Ahmadi, Hessam [1 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Biomed Engn, Tehran, Iran
关键词
biological Signal recording; Blood Pressure; MAP (Mean Arterial Pressure); Oscillometric; bioinstruments;
D O I
10.1109/ICSPIS51611.2020.9349618
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
considering the prevalence of hypertension in communities, the measurement of blood pressure is one of the most important parameters in the field of health. The first biomedical parameter taken from clients in health centers is blood pressure changes. With the advancement of technology in the field of medical engineering, analog blood pressure monitors have gradually been replaced by digital devices, such that the digital blood pressure monitors are used today. In this study, a system was designed and built that measures changes in blood pressure non-invasively and by an oscillometric method with high sampling frequency. In this research, first, the blood pressure hardware was designed and manufactured by instrumentation amplifier circuits to obtain the highest quality pressure signal. Then, in order to receive the signal and send digital data, the sampling frequency of one kHz was set in the microcontroller software to digitize the analog signal with high accuracy. Finally, the blood pressure signals were recorded with very low noise, and also systolic and diastolic pressures were calculated with appropriate quality in LabVIEW software. The performance of the device was tested on 20 subjects and the results were compared with valid digital sphygmomanometer. The number of heartbeats was also displayed according to the processing performed on the signal of changes in blood pressure. The system designed in this study provides the possibility of research on cardiovascular diseases by considering the record of the signal of high sampling frequency blood pressure changes and storing its data on the computer.
引用
收藏
页数:5
相关论文
共 50 条
  • [11] Metabolic Signatures of Blood Pressure and Risk of Cardiovascular Diseases
    Manou, Maria
    Papagiannopoulos, Christos
    Chalitsios, Christos V.
    Asimakopoulos, Alexandros-Georgios
    Markozannes, Georgios
    Bullo, Monica
    Tsilidis, Konstantinos K.
    Papandreou, Christopher
    Tzoulaki, Ioanna
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (23):
  • [12] SEASONAL VARIATION IN BLOOD PRESSURE AND THE RISK OF CARDIOVASCULAR DISEASES
    Ohkubo, Takayoshi
    JOURNAL OF HYPERTENSION, 2023, 41 : E147 - E147
  • [13] Intelligent Continuous Collection Device for High-Pressure Flow Synthesis: Design and Implementation
    Tilley, Michael
    Li, Guanlong
    Savel, Paul
    Mallik, Debasis
    Organ, Michael G.
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2016, 20 (02) : 517 - 524
  • [14] A special device for viscous pressure forming: Design and implementation
    Guo, B
    Xing, XD
    Dai, HM
    Luo, RH
    Wang, ZG
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2001, 17 (01) : 149 - 150
  • [15] A Special Device for Viscous Pressure Forming: Design and Implementation
    Bin GUO
    Xiaodong XING
    Huming DAI
    Ronghua LUO and Zhongren WANG School of Materials Science and Engineering
    Journal of Materials Science & Technology, 2001, (01) : 149 - 150
  • [16] Design and Implementation of a Noninvasive Blood Glucose Monitoring Device
    Sarkar, Kamol
    Ahmad, Dhrubo
    Singha, Suvojit Kumar
    Ahmad, Mohiuddin
    2018 21ST INTERNATIONAL CONFERENCE OF COMPUTER AND INFORMATION TECHNOLOGY (ICCIT), 2018,
  • [17] Study and design of Er:YAG laser blood sampling device
    Zheng, Ji-Hong
    Bao, Liang-Bi
    Ye, Bing
    Shanghai Ligong Daxue Xuebao/Journal of University of Shanghai for Science and Technology, 2001, 23 (04):
  • [18] Comparison of ambulatory blood pressure and clinic blood pressure in relation to cardiovascular diseases in diabetic patients
    Shen, Jian
    Li, Zhi-Ming
    He, Li-Zhen
    Deng, Ren-Sheng
    Liu, Jing-Guang
    Shen, Yuan-Sheng
    MEDICINE, 2017, 96 (33)
  • [19] AUTOMATED BLOOD PRESSURE DEVICE IMPLEMENTATION IN AN ACADEMIC MEDICAL CENTER
    Iheme, Uche Gordon
    Jolly, Stacey
    Coleman, Jennifer D.
    Zahar, Laurie
    Hayden, Stephen P.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2011, 26 : S563 - S563
  • [20] Development and application of a respiratory device on blood pressure in adults with high blood pressure
    Yuenyongchaivvat, Kornanong
    Thanawattano, Chusak
    Buranapuntalug, Sasipa
    Pongpanit, Khajonsak
    Saengkrut, Patcharin
    INTERVENTIONAL MEDICINE AND APPLIED SCIENCE, 2019, 11 (01): : 21 - 26